Laserfiche WebLink
PROJECT Pace Supply <br />FOR The Beacon Group <br />SHEET NO.46 <br />CALCULATED BY TC <br />DATE <br />Brace Analysis: <br />ASSUME SIDE PANEL ACTS AS A SERIES OF 1.25" WIDE "X" BRACES IN RESISTING THE TRANSVERSE  <br />SEISMIC SHEAR. THE PANELS ARE ATTACHED AT REGULAR INTERVALS WITH 1/4" BOLTS. <br />0.7*V=600 LB <br /> Brace: <br />Vhorizontal =857 LB w =1.250 IN <br />20 ga panel t =0.036 IN <br />Vdiagonal =Vhoriz. x (Ldiag/Lhoriz)Area ‐gross =0.045 IN^2 <br />=857 LB x 49 IN / 48 IN Area ‐net =0.032 IN^2 <br />=883 LB <=== Seismic Load in Tension Lhoriz=D =48.00 IN <br />Lvert=Dist. Between bolts =12.00 IN <br />Tension Capacity of the Strip:Ldiag =49.48 IN <br />Fy =36,000 PSI <br />Tallow =0.6 x Fy x Area‐gross Fu =58,000 PSI <br /> =0.6 x 36000 PSI x 0.045 IN^2 Bolt Ø =0.250 IN <br /> =972 LB >  Vdiagonal, ok <br />or <br />Tallow =0.5 x Fu x Area‐net <br /> =0.5 x 58000 PSI x 0.032 IN^2 <br /> =914 LB >  Vdiagonal, ok <br />SHEAR CAPACITY OF 1" STRIP.  <br />A =.036 in^2  <br />Pall=.4 * Fy * Area <br />=518 # <br />  <br />BEARING CAPACITY OF 1" STRIP.  <br />A =.009 in^2  <br />Pall= Fu * Area <br />=522 # <br />SHEAR CAPACITY OF 1/4" BOLT (SAE Gr. 5) (DOUBLE SHEAR) <br />Pall=1 * Area * Fv * 1.0 * 2 <br />=1963#  <br />MATERIAL HANDLING ENGINEERING <br />TEL: (909) 869‐0989 <br />1130 E. CYPRESS STREET, COVINA, CA 91724 <br />INC. <br />SEIZMIC <br />3421 W Segerstrom Ave - <br />10111647610/31/2023