Laserfiche WebLink
PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />ONTIVEROS <br />RESIDENCE <br />4.800 DC kW <br />4.454 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />3409 <br />S OLIVE ST, <br />SANTA ANA, CA <br />92707 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP162149 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN07-28-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Renewable Power AZ <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />A0 <br />PROJECT INFO <br />VICINITY MAP <br />PV NOTES <br />VICINITY MAP <br />AERIAL VIEW <br />PROJECT SITE INFORMATION <br />NAME: EDUARDO ONTIVEROS <br />ADDRESS:3409 S OLIVE ST, <br />SANTA ANA, CA 92707 <br />PHONE: (714) 931-3748 <br />EMAIL: ontiveros.eduardo@yahoo.com <br />APN: <br />41008206 <br />(ORANGE COUNTY) <br />UTILITY: SCE <br />AHJ: SANTA ANA CITY (CA) <br />BUILDING INFO <br />OCCUPANCY: R3-SFD CONSTRUCTION TYPE:VB <br /># OF STORIES: 2 BLDG AREA (SQFT):1802 <br />SPRINKLERS: NONE ROOF AREA (SQFT):2775 <br />ENGINEERING CRITERIA FOR RACKING <br />DESIGN WIND SPEED: 110 MPH <br />WIND EXPOSURE CATEGORY: B <br />GROUND SNOW LOAD: O PSF <br />PROJECT SCOPE <br />INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM <br />PV EQUIPMENT QTY MODEL NO AND MANUFACTURER <br />MODULES:12 TXI10-400108BB 400W (TITAN SOLAR) <br />MISSION SOLAR ENERGY MODULES <br />OPTIMIZERS:12 S440 SOLAREDGE OPTIMIZERS <br />AC COMBINER:1 SE3800H-US (240V) <br />SOLAREDGE HD INVERTER <br />SYSTEM SIZE:4.800 DC kW RATING <br />4.454 CEC AC RATING <br />ARRAY AREA:21.02 SQFT x 12 = 252.27 SQFT <br />MAIN SERVICE PANEL INFORMATION <br />UTILITY: SCE <br />EXISTING: YES UPGRADE:NO <br />BUS RATING: (E)100A MAIN BREAKER:(E)100A <br />PHASE: 1PH MB POSITION:TOP <br /># OF WIRES: 3 DERATE?:NO <br />VOLTAGE: 240V DERATE SIZE:N/A <br />UTILITY FED: OH <br />METER#: 222013-581054 <br />INTERCONNECTION THRU 125A SUBPANEL "POI" <br />SHEET INDEX <br />A0 PROJECT INFO, VICINITY MAP, NOTES <br />A1 SITE PLAN <br />A2 MOUNTING ROOF PLAN <br />E1 SINGLE LINE DIAGRAM <br />E2 ELECTRICAL CALCULATIONS <br />E3 - E3.1 REQUIRED SIGNAGE & DIRECTORY <br />E4 MODULE DATA SHEET <br />E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION <br />E6 OPTIMIZER DATA SHEET <br />S1 STANCHION DATA SHEET <br />S2 RACKING DATA SHEET <br />S3 - S3.1 RACKING ENGINEERING <br />S4 - S4.1 RACKING GROUNDING <br />S5 RACKING FIRE CLASSIFICATION <br />APPLICABLE CODES <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY <br />WITH THE FOLLOWING 2022 APPLICABLE CODES <br />2022 CA BUILDING CODES (CBC) <br />2022 CA RESIDENTIAL CODES (CRC) <br />2022 CA MECHANICAL CODES (CMC) <br />2022 CA PLUMBING CODES (CPC) <br />2022 CA FIRE CODES (CFC) <br />2022 CA ELECTRICAL CODES (CEC) <br />2022 CA ENERGY CODES (CEnC) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) <br />4.800 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT <br />3409 S OLIVE ST, SANTA ANA, CA 92707 <br />ONTIVEROS RESIDENCE <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES <br />2022 CODE REFERENCE <br />CEC 110.2 <br />CEC 110.3 <br />ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER <br />THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS <br />ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. <br />CEC 110.26 WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT <br />CEC ARTICLE 250 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED <br />ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT <br />CEC 690.13 <br />CEC 690.15 <br />DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN <br />READILY ACCESSIBLE LOCATION NEAR THE EQUIPMENT <br />CEC 690.12 RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. <br />CEC 705.40 <br />THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED <br />ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL <br />REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN <br />RESTORED <br />CEC 310.10(D) <br />CEC 690.31(A) TO (F) <br />ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT <br />SUNLIGHT AND FOR THE APPLICATION. <br />CEC 690.31(C INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV <br />SYSTEMS <br />CEC 110.14 FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE <br />USE, <br />CEC 690.31(B) ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION <br />CEC 200.6, CEC <br />200.7 CEC 400.22 <br />CEC 250.119 <br />CEC 400.23 <br />CEC 310.110(C) <br />ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE <br />STRIPES, CEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT <br />COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE <br />COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND <br />GROUNDING CONDUCTORS, CEC 310.110(C). <br />CEC 711.11(C)MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 <br />FEET <br />CEC 705.12(B)CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY <br />DISTRIBUTION EQUIPMENT ON THE PREMISES <br />CFC 605.11.2 DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE <br />SHEATHINGS <br />CEC 250.97 METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER <br />250-VOLTS TO GROUND MUST BE BONDED <br />CEC 314.15 ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS <br />CEC 690.31(C)(5) <br />CEC 110.14. <br />FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR <br />CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE <br />CEC 690.33 (D)(2) <br />CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND <br />OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER <br />LOAD” OR “NOT FOR CURRENT INTERRUPTING” <br />CEC 690.45 <br />CEC 250.122 <br />EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM <br />PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). <br />CEC 705.32 WHERE PROTECTION IS INSTALLED IN ACCORDANCE WITH 230.95, THE OUTPUT OF AN INTERACTIVE SYSTEM <br />SHALL BE CONNECTED TO THE SUPPLY SIDE OF THE GROUND-FAULT PROTECTION. <br /> CEC 690.31(G)(4)THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES <br />MUST BE AT 10' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS <br />CEC 300.4 CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, <br />MUST BE PROTECTED <br />CEC 310.15 <br />WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR <br />CABLES SHALL BE INSTALLED A MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR <br />CABLE OF 7∕8 IN. WHERE THE DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY IS LESS THAN 7∕8 <br />IN., A TEMPERATURE ADDER OF 60°F SHALL BE ADDED TO THE OUTDOOR TEMPERATURE TO DETERMINE THE <br />APPLICABLE AMBIENT TEMPERATURE FOR APPLICATION OF THE CORRECTION FACTORS IN TABLE 310.15(B)(2)(A) <br />OR TABLE 310.15(B)(2)(B). <br />CEC 690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC <br />690.56(C). <br />CEC 690.31(G)(4)LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' <br />IN WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) <br />690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC <br />690.56(C). <br />WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE <br />PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT <br />UPSIZE IT. <br />CRC R324.7 <br />CRC R302.1. <br />GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION <br />DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES <br />EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE <br />COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />CPC 906.1 <br />EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE <br />PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF <br />THE MODULES <br />CMC 802.6.1(1) <br />CPC 509.6.1(1) <br />EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED <br />MODULES, MUST BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). <br />CEC 250.52(A)(5) <br />CEC 250.53(G) <br />GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN <br />CONTACT WITH SOIL <br />CEC 250.104 FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND <br />COLD WATER MUST BE PROVIDED <br />PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL <br />UTILITY COMPANY. <br />CRC R314.1 <br />CRC R315.1 <br />APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL <br />BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE <br />INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR <br />OF THE HOUSE. <br />CRC R324.3 <br />PHOTOVOLTAIC (PV) SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTIONS R324.3.1 <br />THROUGH R324.7.1 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ELECTRICAL PORTION OF <br />SOLAR PV SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL <br />CODE. <br />CRC R324.6 <br />ROOF ACCESS, PATHWAYS AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH <br />SECTIONS R324.6.1 THROUGH R324.6.2.1. ACCESS AND MINIMUM SPACING SHALL BE REQUIRED TO PROVIDE <br />EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR <br />SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESS FROM THE ROOF. <br />A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED <br />AND EXTENDING 3' ABOVE THE ROOF. LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE <br />FOR INSPECTION PURPOSES. <br />CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. <br />ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY <br />INSPECTIONS. <br />PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. <br />ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. <br />NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. <br />PROJECT SITE <br />G:\My Drive\2023\0-TITAN\502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW-MS400-12-SE3.8\23-502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW.dwg <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />08.03.2023 <br />BLDG# 101116377 ISS. 08/29/2023 <br />ELEC# 20180759 ISS. 08/29/2023 <br />The scope of the plans is for the <br />installation of the solar photovoltaic <br />system only and the approval is <br />subject to compliance with all <br />applicable city and state codes and <br />regulations regarding construction. <br />The approval of the plans does not <br />constitute any certification of the <br />accuracy, completeness, or building <br />permit status of the existing buildings <br />and structures as shown. <br />3409 S Olive St <br />08/29/23