My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3409 S Olive St - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Olive St
>
3409 S Olive St
>
3409 S Olive St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:38 PM
Creation date
6/1/2025 12:07:30 PM
Metadata
Fields
Template:
Plan
Permit Number
20180759
101116377
Full Address
3409 S Olive St
Document Relationships
101116377 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Olive St\3409 S Olive St
20180759 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Olive St\3409 S Olive St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:07 PM
Modified:
5/30/2025 4:18 PM
Text:
WWW.TITANSOLARPOWER.COM
ID:
2
Creator:
Import Agent
Created:
6/1/2025 12:07 PM
Modified:
5/30/2025 4:18 PM
Text:
http://www.vincise.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. <br />7 <br />5 <br />" <br />412" <br />MSP INVD SP <br />JB <br />GAS <br />1 <br />2 3' <br /> <br />3'3' <br />3' <br /> <br />18" MIN <br />2 X 6 RAFTERS @ 24" OC <br />PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />ONTIVEROS <br />RESIDENCE <br />4.800 DC kW <br />4.454 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />3409 <br />S OLIVE ST, <br />SANTA ANA, CA <br />92707 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP162149 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN07-28-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Renewable Power AZ <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />MOUNTING PLAN <br />A2 <br />(N) 24 TOTAL <br />ATTACHMENTS <br />@ 4FT ON CENTER <br />(N) 3/4" EMT CONDUIT <br />RUN ABOVE ROOF OR UNDER EAVES <br />WHERE POSSIBLE <br />WIRING/CONDUIT RACEWAY <br /> WILL BE 7/8'' MINIMUM ABOVE THE <br />ROOFTOP PER CEC 310.15(B)(3)(C) <br />FIRE ACCESS POINT#2 <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS <br />OR OTHER <br />OBSTRUCTIONS. <br />FIRE ACCESS POINT#1 <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS <br />OR OTHER <br />OBSTRUCTIONS. <br />SOLAR PANEL DEAD WEIGHT CALCULATION <br />MODULE MISSION SOLAR ENERGY <br />WIDTH (IN)LENGTH (IN)AREA (SQFT) WEIGHT (LBS) QTY <br />TOTAL <br />MODULE <br />AREA <br />TOTAL MODULE <br />WEIGHT <br />44.65 67.80 21.02 46.30 12 252.27 555.60 <br />RACKING UNIRAC <br />RACKING <br />WEIGHT <br />LBS/LNFT <br />MOUNTING <br />SYSTEM WEIGHT <br />TOTAL SYSTEM <br />WEIGHT <br />TOTAL <br />ATTACHMENT <br />POINTS <br />POINT LOAD <br />CALCS DISTRIBUTED LOAD CALCULATION <br />.75 69.45 625.05 24 26.04 2.48 PSF <br />NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 <br />ROOF COVERAGE <br />TOTAL MODULE <br />AREA <br />ROOF FACE AREA <br />(SQFT) <br />ROOF <br />COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE <br />252.27 2775 9.09 % </= 33% 18" SET BACK AT RIDGE <br />ROOF INFORMATION <br />ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS MAX <br />RAFTERS RAFTER SPACING (IN)ATTACHMENT SPACING <br />2 X 6 24" OC 48" OC <br />LEGEND <br />(E) EXISTING <br />(N) NEW <br />(P) PROPOSED <br />CONDUIT RUN <br />VIF VERIFY IN FIELD <br />JUNCTION BOX <br />MAIN SERVICE PANEL <br />AC COMBINER <br />INVERTER <br />AC DISCONNECT <br />SUBPANEL <br />SOLAR METER <br />FIRE ACCESS POINTS <br />FIRE PATHWAY/SETBACKS <br />JB <br />MSP <br />D <br />SP <br />INV <br />AC <br />M <br />x <br />MOUNTING PLAN <br />SCALE: 3/32"=1' <br />NOTE: ALL DIMENSIONS SHOWN <br />RELATING TO EXISTING <br />CONSTRUCTION ARE <br />APPROXIMATE. THE CONTRACTOR <br />SHALL FIELD VERIFY ALL ACTUAL <br />DIMENSIONS. DIMENSIONS, <br />UNLESS NOTED +/- IR VIF (VERIFY <br />IN FIELD), EXACT LOCATIONS, <br />DISTANCES, ELEVATIONS AND <br />SIMILAR DATA SHALL BE <br />GOVERNED BY ACTUAL FIELD <br />CONDITIONS. <br />A <br />SIDE VIEW <br />UNIRAC NXT <br />UMOUNT RAIL & <br />CLAMP <br />BUTYL PAD <br />EXISTING <br />RAFTERS <br />MODULE <br />ROOF <br />SHEATHING <br />ROOF ATTACHMENT DETAIL <br />COMP SHINGLE ROOF <br />SCALE: 1 1/2" = 1' <br />UNIRAC NXT <br />STRONGHOLD <br />ATTACHMENT <br />NOTE: <br />MODULES WILL BE INSTALLED FLUSHED/PARALLEL <br />TO EXISTING ROOF SLOPE <br />2-#12 WOOD SCREWS <br />W/ 1.75" PENETRATION DEPTH <br />(N) 12 - TXI10-400108BB 400W <br /> (TITAN SOLAR) <br />MISSION SOLAR ENERGY MDULES WITH <br />S440 SOLAREDGE OPTIMIZERS <br />STRING A - 12 MODULES <br />18" <br /> <br />M <br />I <br />N <br /> F <br />I <br />R <br />E <br /> <br />S <br />E <br />TB <br />A <br />C <br />K <br />3FT FIRE PATHWAY <br />(E) 100A MAIN SERVICE PANEL <br />SCE METER# 222013-581054 <br />(N) SE3800H-US (240V) <br />SETAPP SOLAREDGE HD <br />INVERTER <br />(E) GAS METER <br />NEW ELECTRICAL <br />EQUIPMENT TO BE 3FT AWAY <br />FROM GAS METER <br />(N) 30A AC DISCONNECT <br />(N) 125A SUBPANEL "POI" <br />A <br />AA <br />AA <br />AA <br />AA <br />A <br />A <br />3FT FIRE PATHWAY <br />268° <br />AZIMUTH <br />28.0° <br />SLOPE <br />G:\My Drive\2023\0-TITAN\502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW-MS400-12-SE3.8\23-502-TSP162149-ONTIVEROS-SANTA ANA-4.8KW.dwg <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />08.03.2023 <br />3409 S Olive St <br />08/29/23
The URL can be used to link to this page
Your browser does not support the video tag.