My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3428 S Saddleback Ct - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Saddleback Crt
>
3428 S Saddleback Crt
>
3428 S Saddleback Ct - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:39 PM
Creation date
6/1/2025 12:07:31 PM
Metadata
Fields
Template:
Plan
Permit Number
20180498
101116104
Full Address
3428 S Saddleback Crt
Document Relationships
101116104 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Saddleback Crt\3428 S Saddleback Crt
20180498 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Saddleback Crt\3428 S Saddleback Crt
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SUNPOWER CORPORATION Document #524734 Rev G <br />SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 <br />Document #524734 Rev G, Vol. 2 1 SunPower Proprietary <br />InvisiMount Span Tables <br />Engineering Summary Letter <br />Volume: 2 <br />ASCE 7 Version: 7-16 <br />Module Type: 22 Sq. Ft. Module <br />Roof Attachment: Composite Shingle <br />High Wind: No <br />High Snow: No <br />The Span Tables are divided into two Parts: <br />• Part 1: Simplified Tables (Wind Tunnel Loads) <br />• Part 2: General Tables (ASCE 7 Analytical Method) <br />Part 1 features spans based on forces on the InvisiMount system using exposure coefficients, GCp, <br />provided by a Wind Tunnel Test Report by Cermak, Petrka, & Petersen (CPP). These values provide a <br />more accurate and economical solution but apply to less configurations. It is recommended to use these <br />values whenever possible, and when not, to use the spans provided in Part 2. <br />Approved Attachments: <br />The following span tables are adequate for the following roof attachments: <br />• SunPower InvisiMount L-Foot attachment <br />• Pegasus Composite Shingle Roof Attachment <br />o And roof attachments with capacities equal to or greater than all of the following Load <br />and Resistance Factor Design (LRFD) values: <br />▪ Tension – 1000lb <br />▪ Compression – 1000lb <br />▪ Shear – 390lb <br />Scope: <br />• Module orientations: Portrait & Landscape <br />• Gable and Hip roofs only with modules not in the overhang sections of the roof <br />• Roof heights <br />o 30ft (Part 1 only) <br />o 20-60ft (Part 2 only) <br />• Roof Slope <br />o 4:12 to 8:12 (Part 1 only) <br />o 2:12 to 12:12 (Part 2 only) <br />• Exposures Categories B, C, D <br />• Basic Wind Speeds: <br />o ASCE 7-10: 110-140mph – High Wind: 145-180mph <br />o ASCE 7-16: 90-130mph – High Wind: 135-180mph <br />• Ground Snow Loads: <br />o 0-60psf (10psf increments) <br />o High Snow Volumes: 80-200psf (20psf increments) <br />o High Wind Volumes: 0psf <br />3428 S <br />Ct08/09/23
The URL can be used to link to this page
Your browser does not support the video tag.