MPACCB <br />---- <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />a <br />l <br />i <br />f <br />o <br />r <br />n <br />i <br />a <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />37 <br />1 <br />7 <br /> <br />S <br />o <br />u <br />t <br />h <br /> <br />O <br />l <br />i <br />v <br />e <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br /> <br />(7 <br />1 <br />4 <br />) <br /> <br />3 <br />1 <br />5 <br />- <br />9 <br />8 <br />6 <br />4 <br />E3.0 <br />SHEET NUMBER: <br />DRAWN BY: <br />DATE:10/26/23 <br />Ro <br />s <br />a <br /> <br />F <br />o <br />n <br />s <br />e <br />c <br />a <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />SU <br />N <br />T <br />E <br />R <br />N <br />A <br />L <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />I <br />N <br />C <br />56 <br />7 <br />1 <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />T <br />E <br />R <br />E <br />S <br />A <br /> <br />B <br />L <br />V <br />D <br />ST <br />E <br /> <br />1 <br />0 <br />5 <br />SA <br />N <br /> <br />J <br />O <br />S <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />5 <br />1 <br />2 <br />3 <br />Li <br />c <br />e <br />n <br />s <br />e <br /> <br /># <br /> <br />1 <br />0 <br />3 <br />6 <br />5 <br />3 <br />6 <br />- <br />B <br />EXISTING HOUSE <br />SCALE: 3/32" = 1'-0" <br />PROPERTY PLAN <br />37 <br />1 <br />7 <br /> <br />S <br />o <br />u <br />t <br />h <br /> <br />O <br />l <br />i <br />v <br />e <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />(N) MAIN SERVICE <br />PANEL 
DISCONNECT#1 <br />(N)AC DISCONNECT <br />DISCONNECT#2 <br />CONDUIT TO BE RUN ON CONDUIT <br />BLOCKS MIN. 1" ABOVE ROOF SURFACE <br />AND UNDER EAVES; CONDUIT TO BE <br />PAINTED TO MATCH EXTERIOR/EXISTING <br />BACKGROUND COLOR OF ITS LOCATION; <br />CONDUIT TO BE LABELED AT MAX 10' <br />INTERVALS. <br />CONDUIT RUN(S) AND JUNCTION BOX(S) <br />LOCATIONS MAY CHANGE DUE TO FIELD <br />CONDITIONS. CONDUIT TO BE <br />INSTALLED PER CRC R331.3 <br />Handled AC disconnect is required and "must" be <br />located within 8 feet of main service panel.No part of <br />the structure can be over 18" in height from the roof <br />without an Professional Engineer's stamp. No structure <br />may increase the height of the building by 10% of it's <br />original height. <br />FIRE SETBACKS REQUIRED: to the ridge on all sides <br />of each roof slope where panels/modules are located, <br />Fire department does not count the gable eaves as <br />part of the 3' fire pathway. 3' pathway must be <br />measured from the exterior bearing wall (applies FOR <br />2:12 ROOFS <br />NOTE: TO PROTECT EMT CONDUIT FROM <br />WEATHER CORROSION USE Paints approved for the <br />purpose. Zinc-rich paints or acrylic, urethane or <br />weather stable epoxy-based resins are frequently used. <br />Oil-based or alkyd paints should not be used. Surface <br />preparation is important for proper adherence. For best <br />results, the conduit / EMT should be washed, rinsed <br />and dried. It should not be abraded, scratched or <br />blasted since these processes could compromise the <br />protective zinc layer. A compatible paint primer or two <br />coats of paint adds protection <br />3' FIRE SETBACK ON VERY WELL <br />STRUCTURED AREA .WITH NO OVER HANG <br />( 16 ) (N) QCELL DUO BLK ML-G10 400W INSTALLED FLUSHED ON ROOF WITH TILT 22° AND 270° AZ, . <br />337.92 FT² OVER SINGLE STORY HOUSE WITH COMP SHINGLE ROOF . <br />PROPERTY LINE <br />DRIVE WAY <br />(N)COMBINER BOX <br />ROOF AREA : 3335.99 SQ.FT <br />ARRAY AREA : 337.92 SQ.FT (10% OF ROOF AREA ) <br />11'-8" <br />5' <br />- <br />8 <br />" <br />4' <br />- <br />7 <br />" <br />18'-2" <br />21 <br />' <br />- <br />6 <br />" <br />3' <br />3' <br />3' <br />5' <br />EXTERIOR LOAD BEARING WALL <br />EXTERIOR LOAD BEARING WALL <br />Exp. 3-31-19 <br />No. C58724 NITRAMW.DYO <br />REGISTEREDPROFESSIONALENGINEER <br />C <br />V <br />L <br />FOETATS <br />ALIFORNIAICIL <br />-25 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2024-0199 Structural Only <br />January 20, 2024 <br />3717 S Olive St- 101118640 & <br />20182388 <br />4/2/2024