P-1.1 <br />PL <br />U <br />M <br />B <br />I <br />N <br />G <br />DE <br />T <br />A <br />I <br />L <br />S <br />TYPICAL FLOOR CLEANOUT <br />TYPICAL WALL CLEANOUT <br />TYPICAL FLOOR SINK TYPICAL TRAP PRIMER DETAIL <br />ELECTRIC WATER HEATER INSTALLATION DETAIL (WH-1) <br />TYPICAL VENT THROUGH ROOF <br />CONDENSATE PIPE <br />SPECIFICATIONS <br />Notes: <br />4" FPT inlet/outlet with 3" and 4" plain end fittings.1. <br />Unit weight - 49 lbs. (wet weight 216 lbs.)2. <br />Maximum operating temperature:3. <br />150º F continuous <br />Capacities - Liquid: 20 gal.4. <br />Grease: 130 lbs. (17.8 gal.) @35 GPM <br />Grease: 127 lbs. (17.3 gal.) @50 GPM <br />Grease (99% -at least 2 units in series ): 180 lbs. (24.7 gal.) <br />@35 GPM <br />Solids: 1.8 gal. <br />Built-in flow control.5. <br />For gravity drainage applications only.6. <br />Do not use for pressure applications.7. <br />Cover placement allows full access to tank for8. <br />proper maintenance. <br />Vent not required unless per local code.9. <br />Engineered inlet and outlet diffusers are10. <br />removable to inspect/clean piping. <br />Integral air relief / anti-siphon.11. <br />Designed for indoor, on-floor, below-grade or low-profile12. <br />under sink installations . <br />ENGINEER SPECIFICATION GUIDE <br />Schier Great Basin™ grease interceptor model # GB2 <br />shall be lifetime guaranteed and made in USA of <br />seamless, rotationally-molded polyethylene with minimum <br />5/16" uniform wall thickness. Interceptor shall be <br />furnished for above or below grade installation. <br />Interceptor shall be certified to ASME A112.14.3 (type C) <br />and CSA B481.1, with field cut riser system, built-in flow <br />control and three outlet options. Interceptor flow rate shall <br />be 35 or 50 GPM. Interceptor grease capacity shall be <br />130 lbs. @ 35 GPM or 127 lbs. @ 50 GPM. Cover shall <br />provide water/gas-tight seal and have minimum 450 lbs. <br />load capacity. <br />CERTIFIED PERFORMANCE <br />Great Basin™ hydromechanical grease interceptors <br />are third party performance-tested and listed by <br />IAPMO to ASME #A112.14.3 and CSA B481.1 <br />grease interceptor standards and greatly exceed <br />requirements for grease separation and storage. <br />They are compliant to the Uniform Plumbing Code, <br />the National Standard Plumbing Code, the National <br />Plumbing Code of Canada, and the International <br />Plumbing Code. <br />Satisfies Miami DERM 99% efficiency requirements when at least 2 <br />units are installed in series . Product labels are permanently attached <br />to inside and outside of unit for easy viewing. <br />6455 Woodland Dr <br />Shawnee, KS 66218 <br />Tel: 913-951-3300 <br />Fax: 913-951-3399 <br />schierproducts.com <br />DESCRIPTION: <br />DWG BY:DATE:REV: <br />THE INFORMATION CONTAINED IN THIS DRAWING IS <br />THE SOLE PROPERTY OF SCHIER PRODUCTS. ANY <br />REPRODUCTION IN PART OR AS A WHOLE WITHOUT <br />THE WRITTEN PERMISSION OF SCHIER PRODUCTS IS <br />PROHIBITED. <br />PROPRIETARY AND CONFIDENTIAL <br />C.SINCLAIR 5/5/2022 -ECO: <br />MODEL NUMBER: <br />GB2 GREASE INTERCEPTOR 35 GPM / 50 GPM, 4" FPT INLET/OUTLET, WITH <br />3" AND 4" PLAIN END FITTING ADAPTERS AND PEDESTRIAN RATED COVER <br />- <br />4065-001-05PART NUMBER: <br />GB2 <br />SPECIFICATION SHEET <br />FLOW <br />12-7/16" <br />35" <br />TOP VIEW <br />(COVER REMOVED FOR CLARITY) <br />Outlet "A" <br />(Optional) <br />Outlet "C" <br />(Optional) <br />Outlet "B" <br />(Standard) <br />Outlet Foot <br />Must Face This <br />Direction In All <br />Configurations <br />Inlet <br />AA <br />23" <br />13-3/4" <br />END VIEW <br />8-3/4" <br />5" <br />Ø 21-1/2" Cover <br />6-3/4" <br />INVERT <br />SECTION A-A <br />Engineered Inlet and <br />Outlet Diffusers <br />See Note #11 <br />CL of 4" FPT <br />Inlet and Outlet <br />Static Water Line <br />Flow Control <br />ISOMETRIC VIEW <br />3851 S Bristol St - 101117837, <br />20181795, 30146742 <br />7/9/2024