My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3825 S Alder St - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Alder St
>
3825 S Alder St
>
3825 S Alder St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:07:45 PM
Creation date
6/1/2025 12:07:38 PM
Metadata
Fields
Template:
Plan
Permit Number
20178089
101112956
Full Address
3825 S Alder St
Document Relationships
101112956 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alder St\3825 S Alder St
20178089 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alder St\3825 S Alder St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV-3 <br /> PROJECT NO. <br />DATEREVISION <br /> DATE: 08/25/2022 <br /> DRAWN BY: A.B. <br />8. <br />0 <br />0 <br /> <br />k <br />W <br /> <br />D <br />C <br /> S <br />Y <br />S <br />T <br />E <br />M <br /> <br />RI <br />C <br />H <br />E <br />L <br />L <br />E <br /> <br />F <br />L <br />O <br />R <br />E <br />S <br />38 <br />2 <br />5 <br /> <br />A <br />L <br />D <br />E <br />R <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />9 <br />1 <br />0 <br />- <br />9 <br />1 <br />9 <br />1 <br />LE <br />G <br />A <br />L <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />/ <br />A <br />P <br />N <br />: <br /> <br />4 <br />1 <br />0 <br />0 <br />3 <br />1 <br />1 <br />5 <br />LIC. -1018672 <br />C-10 <br />ELECTRICAL NOTES: <br />· ALL PLAQUES AND SIGNAGE REQUIRED BY THE 2019 EDITION OF CALIFORNIA ELECTRICAL CODE AND THE AHJ AREA ELECTRICAL NEWSLETTER, WILL BE INSTALLED AS REQUIRED. <br />· ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC WITH ENGRAVED LETTERING IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER <br />APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. <br />· EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136 (A) REGARDLESS OF <br />VOLTAGE. <br />·IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. <br />·ACCESS TO DC WIRING WILL BE RESTRICTED TO QUALIFIED PERSONAL ONLY. <br />·NEW BACK FED PV BREAKER SHALL BE POSITIONED AT OPPOSITE END OF MAIN BREAKER. <br />·BATTERY CIRCUIT BREAKER SHALL COMPLY WITH CEC ART. 690.10, 705.15(E) AND 408.36 (D). <br />·PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET WITH MINIMUM 3/8 INCH HIGH WHITE LETTERING ON RED <br />BACKGROUND READING: "WARNING: PHOTOVOLTAIC POWER SOURCE". <br />·ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />·ELECTRICAL EQUIPMENT THAT ARE IN OTHER THAN DWELLING UNITS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF A POTENTIAL ARC FLASH. 110.16 <br />·NEC 690.13(B) EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED “PV SYSTEM DISCONNECT” OR <br />EQUIVALENT. ADDITIONAL MARKINGS SHALL BE PERMITTED BASED UPON THE SPECIFIC SYSTEM <br /> CONFIGURATION. FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE <br /> ENERGIZED IN THE OPEN POSITION, THE DEVICE SHALL BE MARKED WITH THE FOLLOWING WORDS OR EQUIVALENT: “TERMINALS <br /> ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION.” <br />· THE RAPID SHUTDOWN INITIATION METHODS SHALL BE LABELED IN ACCORDANCE WITH 690.56(C). <br />· 690.12 RAPID SHUTDOWN OF PV SYSTEMS ON BUILDINGS. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIfiC CONDUCTORS IN <br />ACCORDANCE WITH 690.12(1) THROUGH (5) AS FOLLOWS. <br />· 690.64 POINT OF CONNECTION. POINT OF CONNECTION SHALL BE IN ACCORDANCE WITH 705.12. <br />THE RACKING SYSTEM IS LISTED TO UL 2703 FOR INTEGRATED GROUNDING; <br />MODULES ARE AN ELECTRICAL BONDING COMPONENT AND ARE LISTED TO UL <br />1741; THUS NO ADDITIONAL GROUNDING HARDWARE, LUGS, OR COPPER WIRE <br />ARE REQUIRED ON THE ROOF. <br /> NEW 225A MAIN <br />SERVICE PANEL <br />W/ 200A MCB <br />EXISTING <br />HOME <br />GROUNDING <br />SYSTEM <br />40A <br />NEW <br />ENPHASE IQ <br />COMBINER BOX W/ <br />INTEGRATED <br />MONITOR <br />ENPHASE <br />TRUNK CABLE #12 <br />(1) #6 GND <br />TO J-BOX <br />(4) #10 THWN-2 <br />(1) #8 GND <br />3/4 " E.M.T. <br />#11 <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />#1 <br />20A <br />(20) HANWHA Q-CELLS Q.PEAK <br />DUO BLK G10+ 400 MODULES <br />(20) ENPHASE IQ7A-72-2-US <br />MICRO INVERTERS <br />MAX AC OUTPUT=1.45A <br />200A <br />MCB(3) #8 THWN-2 <br />(1) #8 GND <br />3/4 " E.M.T. <br />#9 <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />#1 <br />20A <br />PV BREAKER - RAPID <br />SHUTDOWN INITIATION DEVICE <br />3825 S Alder St <br />06/30/23
The URL can be used to link to this page
Your browser does not support the video tag.