Laserfiche WebLink
RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />40 <br />1 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(9 <br />0 <br />9 <br />) <br /> <br />7 <br />5 <br />7 <br />- <br />8 <br />4 <br />6 <br />0 <br />NG <br />U <br />Y <br />E <br />N <br />, <br /> <br />P <br />A <br />U <br />L <br />AP <br />N <br />: <br /> <br />3 <br />9 <br />8 <br />2 <br />9 <br />1 <br />0 <br />1 <br />DA <br />T <br />E <br />X_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />LI <br />C <br /># <br />: <br /> <br />1 <br />0 <br />4 <br />1 <br />3 <br />1 <br />7 <br />, <br /> <br />C <br />- <br />1 <br />0 <br />, <br /> <br /> <br />E <br />X <br />P <br />. <br /> <br />0 <br />6 <br />/ <br />3 <br />0 <br />/ <br />2 <br />0 <br />2 <br />4 <br />SI <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />PV-1.2 <br />SCALE: 9/64" = 1'-0" <br />MODULE LOCATION SCHEDULE <br />LOC.SLOPE AZIMUTH QTY <br />A 27°180°8 <br />2H2 = 10" MINIMUM DISTANCE <br />JB = JUNCTION BOX <br />POINT LOAD CALCULATIONS <br />TOTAL SIZE OF PV MODULES 3.16 KWDC <br />#OF PV MODULES 8 MODULES <br />LBS PER PV MODULE 51.6 LBS <br />RACKING WEIGHT ADDED PER PV <br />MODULE 1.5 LBS <br />TOTAL ADDITONAL WEIGHT ADDED <br />TO ROOF 424.8 LBS <br />PV MODULE AREA 21.9 SQ. FT <br />TOTAL PV ARRAY AREA 175 SQ FT <br />LBS / SQ. FT/ (*<4.0 IS OK)2.4 OK <br />TOTAL # VERTICAL SUPPORTS: <br />SPACED 72" APART 16 <br />WEIGHT PER SUPPORT <br />(LESS THAN 40 LBS IS OK)26.6 OK <br />ROOF COVERAGE (%) <br />PV ARRAY AREA 176 SQ. FT. <br />ROOF FACE AREA 1400 SQ. FT. <br />ROOF COVERAGE 12.6 ≤33 <br />ROOF COVERAGE ≤ 33% THEREFORE 18" SETBACK AT <br />RIDGE PER R324.6.2 <br />EXISTING 2" x 6" @ 32" <br />RAFTERS O.C. TYP. <br />18" FIRE PATH SETBACK PER <br />CRC R324.6.2 <br />36" FIRE PATH SETBACK PER <br />CRC R324.6.1 <br />(N) AC DISCONNECT SWITCH <br />(E) MAIN ELECTRICAL <br />SERVICE <br />ROOF ACCESS POINT PER CRC <br />R324.6.1 <br />(N) SOLAREDGE SE3000H-US <br />(240V) INVERTER <br />(N) CANADIAN SOLAR <br />CS3N-395MS [BLK] MODULES <br />395 WATTS, TOTAL QTY: 8 <br />(E) LOAD CENTER <br />401 S Ross St <br />11/30/2023