(N) VISIBLE <br />LOCKABLE <br />2 POLE 30A <br />'KNIFE' AC <br />DISCONNECT <br />AC <br />DISCONNECT <br />TO BE LOCATED <br />WITHIN 10' OF <br />METER <br />M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />N <br />(E) GROUNDING <br />ELECTRODE <br />OR (UFER) <br />EXISTING <br />240V/100A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />100A <br />BACKFEED <br />BREAKER <br />20A <br />4 <br />(N) 240V/200A <br />SUB SERVICE PANEL <br />SINGLE PHASE <br />3 <br />N <br />100A <br />20A <br />EXISTING WIRE <br />G G <br />L1 <br />N <br />L2 <br />(E) (16) EXISTING SOLAR MODULES <br />(E) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />G <br />ST <br />R <br />I <br />N <br />G <br /> <br /># <br />1 <br />ST <br />R <br />I <br />N <br />G <br /> <br /># <br />2 <br />PV CIRCUIT 2: 8 MODULES/PARALLEL <br />PV CIRCUIT 1: 8 MODULES/PARALLEL <br />EXISTING WIRE <br />EXISTING WIRE <br />RO <br />O <br />F <br />T <br />O <br />P <br />GR <br />OU <br />ND <br /> <br />LE <br />V <br />E <br />L <br /> - <br />HO <br />U <br />S <br />E EX <br />T <br />E <br />R <br />I <br />OR <br />2(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />(N) (8) SOLAREVER SE-166*83-455M-144 (455W) MODULES <br /> WITH (4) AP SYSTEM DS3-L MICRO-INVERTER <br />ATTACHED TO THE BACK OF MODULE. <br />1 <br />PV CIRCUIT 1: 8 MODULES/PARALLEL [(4) AP SYSTEM DS3-L 2 IN 1] <br />11 2 <br />(E) STRING INVERTER <br />ALL EXISTING LOADS <br />RELOCATED FROM MAIN <br />SERVICE PANEL TO NEW <br />SUB SERVICE PANEL <br />7 8 <br />(E) VISIBLE <br />LOCKABLE <br />2 POLE 30A <br />'KNIFE' AC <br />DISCONNECT <br />N <br />N <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />3701 S SYCAMORE ST, <br /> SANTA ANA, <br /> CA 92707 <br /> APN:41003245 <br /> DATE:1/25/2023 <br />WIGGS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: OSA <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />E-1 <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW -2°C <br />ASHRAE 2% HIGH 37°C <br />PV Module Ratings @ STC <br />Module Make/Model <br />SOLAREVER <br />SE-166*83-455M-144 <br />(455W) MODULE <br />Max Power-Point Current (Imp)10.96A <br />Max Power-Point Voltage (Vmp)41.51V <br />Open-Circuit Voltage (Voc)49.35V <br />Short-Circuit Current (Isc)11.41A <br />Max Series Fuse (OCPD)20A <br />Nominal Maximum Power at STC (Pmax)455W <br />Maximum System Voltage 1500V <br />Voc Temperature Coefficient -0.29% /°C <br />SUB SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 200A <br />MAX BREAKER SIZE: <br />(200A X 1.2) - 100A = 140A <br />Inverter Ratings <br />Inverter Make/Model AP SYSTEM DS3-L <br />Max DC Volt Rating 60V <br />Peak Output Power 768W <br />Max Nominal Voltage 240V <br />Max AC Current 3.2A <br />Max OCPD Rating 20A <br />SYSTEM SUMMARY <br />INVERTERS PER BRANCH 4 <br />MAX AC CURRENT 12.8A <br />MAX AC OUTPUT POWER 3072W <br />ARRAY STC POWER <br />ARRAY PTC POWER <br />MAX AC CURRENT <br />MAX AC POWER <br />DERATED (CEC) AC POWER <br />METER # 222013010019 <br />BRANCH #1 <br />3640W <br />3397.60W <br />12.8A <br />3072W <br />3278.68W <br />Conduit and Conductor Schedule ~(75°C Copper Column) <br />Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size <br />1 PV WIRES 10 AWG 1 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 2 EMT 3/4" <br />2 THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />(E) PV SYSTEM IS RSD COMPLIANT <br />3 THWN-2 10 AWG 3 EMT 3/4" <br />3 THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />4 THWN-2 3 AWG 3 EMT 1-1/4" <br />4 THWN-2 - Ground 6 AWG 1 EMT 1-1/4" <br />NOTE:TOTAL AMPERAGE RATING OF <br />ALL OVERCURRENT DEVICES SUMMED <br />UP IN THE MAIN PANEL EXCLUDING <br />MAIN SUPPLY OVERCURRENT DEVICE, <br />SHALL NOT EXCEED AMPACITY OF BUS <br />BAR NEC 2017 705.12(D)(2)(3)(c) <br />3701 S Sycamore St <br />02/23/23