N <br />1'-6" <br />3' <br />3' <br />1'-6" <br />3' <br />SCALE: 3/32" = 1'-0" <br />PV SYSTEM SITE PLAN <br />PV SYSTEM SIZE: <br />3.64 kW DC <br /> LEGEND <br />M METER MAIN COMBO <br />CONSTRUCTION NOTES <br />PV INTERCONNECTION POINT. <br />LOCATION OF SUB SERVICE PANEL, <br />AC DISCONNECT MOUNTED ON <br />EXTERIOR WALL OF A SINGLE <br />FAMILY RESIDENCE. <br />NEW SOLAR PANELS <br />DRIVEWAY <br />(8) SOLAREVER SE-166*83-455M-144 (455W) <br />WITH (4) AP SYSTEM DS3-L MICROINVERTERS <br />MOUNTED TO THE BACK OF MODULES MOUNTED <br />ON COMP SHINGLE <br />37 <br />0 <br />1 <br /> <br />S <br /> <br />S <br />Y <br />C <br />A <br />M <br />O <br />R <br />E <br /> <br />S <br />T <br />ROOF OBSTRUCTIONS <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br />3701 S SYCAMORE ST, <br /> SANTA ANA, <br /> CA 92707 <br /> APN:41003245 <br /> DATE:1/25/2023 <br />WIGGS <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: OSA <br />CORE ENERGY GROUP. <br />ADDRESS: 2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />PV-1 <br />LOCATION OF "RAPID SHUTDOWN" AC <br />DISCONNECT CEC 690.12 <br />ACDSSP <br />MURPHY AVE <br />INV EXISTING STRING INVERTER <br />SSP SUB SERVICE PANEL <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON <br />RESIDENTIAL STRUCTURE. <br />2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH <br />THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND <br />SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C. <br />3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON <br />CENTER. CONNECTION TO STRUCTURE SHALL NOT BE <br />WITHIN 11" OF NAILING PLATES. <br />4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT <br />OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING <br />ROOF VENTS. <br />5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF <br />SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE <br /> (INCLUDING CABLES UNDERNEATH MODULES AND <br />RACKING). <br />6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE <br />FOLLOWING (CRC R324.7.1, CBC 3111.2.1) <br />6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF <br />GROUND LADDERS OVER OPENINGS SUCH AS DOORS <br />OR WINDOWS. <br />6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: <br />TREES, WIRES, OR SIGNS. <br />7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN <br />COMPLIANCE WITH 2022 CFC/2022 IFC 1204.2.1.2 <br />TOTAL PLAN VIEW AREA = 2393 SQFT <br />TOTAL PV AREA FOR NEW SYSTEM = 8(82.44 IN)(40.86 IN)/(144 <br />IN^2) = 187.14 SQFT =(187.14 SQFT/ 2393 SQFT)100 = 7.82% <br /> TOTAL PV AREA FOR EXISTING SYSTEM <br />=16(69 IN)(34 IN)/(144 IN^2) = 260.66 SQFT <br />=(260.66SQFT/ 2393 SQFT)100 = 10.89% <br />TOTAL PV AREA FOR NEW AND EXISTING SYSTEM. <br />(187.14+260.66) SQFT/ 2393 SQFT = 18.71% <br />TOTAL PV AREA POPULATES 18.71% OF TOTAL PLAN <br />VIEW AREA AND IS WITHIN THE 33% REQUIREMENT. <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />M <br />LOCATION OF EXISTING STRING <br />INVERTER& AC DISCONNECT. <br />(E) SOLAR SYSTEM <br />ACD AC DISCONNECT <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />LOCATION OF METER MAIN COMBO <br />Roof Azimuth: 270 ° <br />Roof Ti lt: 19 ° <br />Roof Section 2 <br />INV <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />PROPERTY LINE <br />Roof Azimuth: 180° <br />Roof Tilt: 19° <br />Roof Section 1 <br />ACD <br />PROPERTY LINE <br />PROPERTY LINEPROPERTY LINE <br />1/25/2023 <br />3701 S Sycamore <br />St02/23/23