Laserfiche WebLink
Project : <br />Project Number: <br />By : <br />Date : <br />Lopez, Byron <br />PE <br />13-12-2022 <br />Check for Increase in overall seismic loads <br />Array Area = ft2 <br />Number of Arrays = <br />Total Array Area = ft2 <br />Array Load = psf <br />Number of Existing Arrays = <br />Exisitng Area = ft2 <br />Total Array Wt. = lb <br />Total Roof Area = ft2 <br />DL of Roof = psf <br />Total Wt of Roof = lb <br />Increase in Seismic Wt = < <br />13.00 <br />35204 <br />2.8% 10% <br />Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than <br />10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2019 <br />CEBC. <br />21.9 <br />15 <br />328.68 <br />2707.3 <br />3.00 <br />986.04 <br />0 <br />0.00 <br />3510 S Woodland <br />Pl02/10/23