Laserfiche WebLink
CBMSPUMACD <br />JB <br />~100.47'~6 <br />. <br />4 <br />2 <br />' <br />~5 <br />3 <br />. <br />5 <br />9 <br />' <br />~101.01' <br />~6 <br />0 <br />. <br />0 <br />0 <br />' <br />3' <br />- <br />1 <br />" <br />26'-10" <br />21'-9" <br />1' <br />- <br />2 <br />" <br />SITE PLAN WITH ROOF PLAN <br />REV <br />SHEET NAME <br />SHEET NUMBER <br />DATE DESCRIPTION <br />VERSION <br />PV-1 <br />PROJECT NAME <br />UR11/22/2022 INITIAL RELEASE <br />LO <br />P <br />E <br />Z <br />, <br /> <br />B <br />Y <br />R <br />O <br />N <br />35 <br />1 <br />0 <br /> <br />S <br /> <br />W <br />O <br />O <br />D <br />L <br />A <br />N <br />D <br /> <br />P <br />L <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br /> 4 <br />1 <br />0 <br />1 <br />9 <br />3 <br />2 <br />1 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />ENERGY RENOVATION CENTER <br />11731 Sterling Avenue, Unit G <br /> Riverside, CA 92503 <br />LIC:- 1009326 <br />PH:- 8886040226 <br />pm@energyrenovationcenter.com <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />LEGEND <br />UTILITY METER <br />AC DISCONNECT <br />JUNCTION BOX <br />UM <br />ACD <br />JB <br />MSP MAIN SERVICE PANEL <br />GATE <br />FENCE <br />CONDUIT <br />VENT, ATTIC FAN <br />(ROOFOBSTRUCTION) <br />CHIMNEY <br />ENPHASE IQ COMBINER 4CB ROOF DESCRIPTION <br />ROOF TYPE COMP SHINGLE <br />ROOF <br />ROOF <br />ARRAY <br />ROOF <br />TILT AZIMUTH PV AREA <br />(SQ.FT.) <br />NO. OF <br />MODULE <br />#1 20° 270° 328.68 15 <br />S <br />W <br />O <br />O <br />D <br />L <br />A <br />N <br />D <br /> <br />P <br />L <br />(E) TREE (TYP.) <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />DR <br />I <br />VE <br />W <br />A <br />Y <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />ONE- STORY <br />HOUSE <br />(E) STRUCTURE <br />(E <br />) <br /> <br />P <br />A <br />T <br />I <br />O <br />(E) FENCE <br />ROOF ACCESS POINT <br />ROOF #1 <br />(15) CANADIAN SOLAR CS3N-395MS <br />(395W) MODULES <br />(E) UTILITY METER <br />(N) 225A MAIN SERVICE PANEL <br />WITH (N) 200A MAIN BREAKER <br />(N) 30A NON FUSED AC DISCONNECT <br />(N) ENPHASE IQ COMBINER BOX 4 <br />(N) 3/4" OR GREATER EMT CONDUIT <br />RUN (7/8 INCHES ABOVE ROOF) <br />(N) JUNCTION BOX <br />FL <br />O <br />W <br />E <br />R <br /> <br />S <br />I <br />D <br />E <br /> <br />P <br />A <br />T <br />H <br />(E) STRUCTURE <br />STRUCTURAL ONLY <br />13 Dec 2022 <br />EXP : 30 Sep 2023 <br />3510 S Woodland <br />Pl02/10/23