(E) BEDROOM 1 <br />(E) LIVING AREA <br />(E) BEDROOM 2 <br />(E) BEDROOM 3 <br /> ( <br />E <br />) <br /> <br />B <br />A <br />T <br />H <br /> <br />1 <br />(E) KITCHEN <br /> ( <br />E <br />) <br /> <br />B <br />A <br />T <br />H <br /> <br />2 <br />DWWH <br />ATTIC <br />ACCESS <br />(E) PATIO <br />COVER <br />49'-0" <br />2'-7" <br />20'-3" <br />F.A.U. <br />13'-8" <br />15'-9" <br />3'-9" <br />10'-9" <br />66'-11" <br />23'-0" <br />13'-4" <br />14'-6" <br />15'-9" <br />4'-4"4'-4"13'-0"13'-0"12'-5"12'-5" <br />50'-0" <br />(E) 96"80" VINYL SLIDING DOOR (E) 96"36" VINYL WINDOW (E) 96"36" VINYL WINDOW <br />(E <br />) <br /> <br />4 <br />8 <br />" <br />2 <br />4 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E) 60"48" VINYL WINDOW <br />(E) 48"24" VINYL <br />WINDOW <br />(E) 48"24" VINYL <br />WINDOW <br />(E <br />) <br /> <br />4 <br />8 <br />" <br />3 <br />6 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E <br />) <br /> <br />7 <br />2 <br />" <br />2 <br />4 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />SD <br />SD <br />SD <br />UL 2034/2075 RATED <br />@ (E) HOUSE (TYP.) <br />COSD <br />UL 217 RATED @ <br />(E) HOUSE (TYP.) <br />SD <br />SD <br />ATTIC <br />ACCESS <br />22" x 30" <br />(N) ADU <br />100A PANEL <br />AFCI (TYP.) <br />GFCI (TYP.) <br />1. GLAZING IN SHOWER AND BATHTUB <br />SHALL BE TEMPERED GLASS WHERE <br />OCCURS (CBC 2406) <br />2. ALL PLUMBING FIXTURES AND <br />FITTINGS SHALL COMPLY WITH THE <br />MAXIMUM ALLOWABLE FLOW RATES. <br />3. WALL COVERINGS SHALL BE CEMENT <br />PLASTER, TILE OR APPROVED EQUAL <br />TO 72" ABOVE DRAIN AT SHOWERS OR <br />TUB WITH SHOWERS. MATERIALS <br />OTHER THAN STRUCTURAL ELEMENTS <br />ARE TO BE MOISTURE RESISTANT. <br />(N <br />) <br /> <br />K <br />I <br />T <br />C <br />H <br />E <br />N <br />(N) BEDROOM <br />(N) LIVING <br />AREA <br />HOOD VENT <br />THROUGH ROOF, <br />MIN. 300 CFM, MAX. 3 <br />SONES. INSTALLED <br />PER MANU. SPECS. <br />SD <br />CO <br />SMOKE DETECTOR IN <br />LIVING ROOM (WITHIN 20' <br />FROM THE COOK TOP) <br />SHALL BE IONIZED OR <br />PHOTOELECTRIC TYPE <br />RESERVE SPACE FOR (3) <br />DOUBLE POLE CIRCUIT <br />BREAKERS FOR FUTURE <br />ELECTRIC CLOTHES <br />DRYER, WATER HEATER <br />AND COOKTOP, MARKED <br />AS "FOR FUTURE 240V USE" <br />MAX. 48" MEASURED <br />FROM TOP, MIN. 15" <br />MEASURED FROM <br />BOTTOM OF BOX <br />ABOVE F.F. (TYP.) <br />(E) MAIN UNIT <br />200A PANEL <br />(E) AC <br />WR-GFCI <br />(E) 72"36" VINYL WINDOW <br />(E) WH IN HOLDRITETM GALVANIZED <br />STEEL ENCLOSURE AND B-VENT <br />EXHAUST TERMINATED 3' ABOVE <br />ROOF, SCHEDULE 40 METALLIC 3/4" <br />GAS PIPE. IF NOT PRESENT, STRAP <br />AS PLUMBING NOTE 10 HEREON. <br />30" <br />1,024 SI <br />1' <br />- <br />7 <br />" <br />1' <br />- <br />4 <br />" <br />STACKED <br />W/D <br />(N) AC <br />CONDENSER ON <br />3" CONCRETE PAD <br />3"5'-0" <br />WH <br />(N) BATH <br />10'-0" <br />10'-9" <br />5'-7" <br />17'-9" <br />11'-8" <br />S-S S-S <br />3'-0" <br />10 <br />0 <br />A <br />SU <br />B <br />- <br />P <br />A <br />N <br />E <br />L <br />14 <br />SD-1 <br />DUCTLESS MINI <br />SPLIT WALL CONSOLE <br />DUCTLESS MINI <br />SPLIT WALL CONSOLE <br />GRAB BAR <br />REINFORCEMENT, <br />MIN. 2x8 LUMBER, <br />32"-39.25" ABOVE F.F. <br />AFCI (TYP.) <br />WR <br />- <br />G <br />F <br />C <br />I <br />$D <br />SD <br />AFCI (TYP.) <br />$VS$ <br />$$ <br />$W/D$ <br />WR-GFCI <br />30 AMP. <br />WR-GFCI <br />30 AMP., LABELED <br />"240V READY" ON <br />BLANK COVER <br />30 AMP., LABELED <br />"240V READY" ON <br />BLANK COVER <br />50 AMP., LABELED <br />"240V READY" ON <br />BLANK COVER <br />OUTDOOR TANKLESS <br />WH INSTALLED BY <br />MANU. SPECS., ON 1" <br />DEDICATED GAS LINE <br />$3$3D <br />$3$ <br />$3 <br />ENCLOSURE TO BE STUCCO <br />SPRAYED, FINISH TO MATCH (E) <br />UNIT IN COLOR AND TEXTURE <br />(N) FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />NEW WALL, 2x4 STUDS @ 16" O.C. <br />U.N.O. <br />EXISTING STUD WALL <br />WALL LEGEND <br />CARBON MONOXIDE AND SMOKE DETECTOR NOTES <br />SMOKE DETECTOR SHALL BE PROVIDED IN EACH SLEEPING ROOM <br />AND AREA GIVING ACCESS TO THE SLEEPING ROOMS <br />1. NEW CONSTRUCTION: CO AND SMOKE DETECTORS SHALL RECEIVE <br />THEIR PRIMARY POWER FROM BUILDING WIRING WITH BATTERY <br />BACKUP. <br />2. EXISTING MAIN HOUSE: BATTERY POWERED UL 2034/2075 RATED <br />CARBON MONOXIDE ALARM AND UL 217 RATED SMOKE ALARMS SHALL <br />BE INSTALLED IN MARKED LOCATIONS. <br />ELECTRICAL NOTES <br />1.PROVIDE ONE 20 AMP. CIRCUIT FOR BATHROOM OUTLETS. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS. <br />2.PROVIDE 2 DEDICATED GENERAL APPLIANCE CIRCUITS TO THE KITCHEN AREA. <br />3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. <br />4.ALL RECEPTACLES IN BATHROOMS SHALL BE G.F.C.I. <br />5.SERVICE PANEL/METER UPGRADE OR NEW: OBTAIN LOCATION APPROVAL FROM THE ELECTRICAL <br />PROVIDER. <br />6.ALL BRANCH CIRCUITS SUPPLYING RECEPTACLE OUTLETS IN KITCHENS, BEDROOMS, FAMILY <br />ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, DENS, SUNROOMS, HALLWAYS, CLOSETS AND <br />SIMILAR ROOMS/AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (AFCI). <br />7.NON-HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HIGH <br />EFFICACY LUMINAIRES. <br />8.ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED <br />HORIZONTALLY BY 24" . BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT <br />AND BACKED WITH 2" MIN. MINERAL FIBER INSULATION. <br />9.ALL RECEPTACLE OUTLETS SHALL BE LISTED AS TAMPER-RESISTANT OUTLETS. <br />10.ALL OUTDOOR LIGHTING MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY LIGHTING <br />OR CONTROLLED BY A PHOTOCELL AND MOTION SENSOR COMBINATION. <br />PLUMBING NOTES <br />1.BATH FAN SHALL BE CONTROLLED BY HUMIDISTAT WITH ADJUSTMENT BETWEEN A RELATIVE <br />HUMIDITY RANGE 50-80%. <br />2.SHOWER WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, <br />NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6' ABOVE FLOOR. <br />3.SHOWER COMPARTMENT SHALL BE MINIMUM 1,024 SQ. IN. AND SHALL BE CAPABLE OF <br />ENCOMPASSING A 30 IN. CIRCLE. <br />4.PROVIDE A 12"x12" MINIMUM ACCESS PANEL TO BATHTUB TRAP CONNECTION UNLESS PLUMBING IS <br />WITHOUT SLIP JOINTS (CPC 405.2). <br />5.ALL TOILETS SHALL BE 1.28 GPF, SHOWERHEADS 2.0 GPM, AND FAUCETS 1.2 GPM, KITCHEN FAUCET <br />1.8 GPM. <br />6.FOR SHOWERS OR TUB-SHOWERS MAX. TEMPERATURE OF 120 DEGREE TO BE PROVIDED BY THE <br />USE CONTROL VALVE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. <br />7.ALL GLAZING IN ALL DOORS, BATH/SHOWER ENCLOSURES MUST BE IDENTIFIED BY A LABEL AS A <br />SAFETY GLAZING. <br />8.WALL COVERING IN SHOWERS AND TUBS TO BE CEMENT PLASTER OR TILE EQUAL TO 72" ABOVE <br />DRAIN. ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF <br />SHOWERS. WINDOWS IN ENCLOSURE WALLS SHALL BE LABELED SAFETY GLAZING WHEN LESS THAN <br />60" ABOVE THE DRAIN, TYPICAL FOR ALL BATHROOMS. <br />9.GREEN BOARD GYPSUM OR WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED AS BACKING <br />FOR CEILING FINISH INSIDE BATHROOM DUE TO CONDENSATION OR VAPOR. <br />10.WATER HEATER: SIZE PER TITLE 24 WITH VENT THROUGH OUTSIDE. PROVIDE P&T RELIEF VALVE ON <br />WATER HEATER. PROVIDE SMITTY PAN WITH DRAIN INSULATION/CLEARANCE PER MANUFACTURER <br />SPECS. WATER HEATER TANK (IF USED) MUST BE ADEQUATELY BRACED TO RESIST SEISMIC <br />FORCES: PROVIDE 2 STRAPS, 1 STRAP AT TOP 1/3 OF TANK AND 1 STRAP AT BOTTOM 1/3 OF THE <br />TANK. <br />11.PLUMBING VENT TERMINATIONS SHALL BE AT LEAST 10' FROM FRESH AIR INTAKE OR VENTILATION. <br />12.B-VENTS SHALL TERMINATE AT LEAST 4' FROM FRESH AIR INTAKE OR VENTILATION. <br />WINDOW SCHEDULE <br />WINDOWS' U-FACTOR AND SHGC PER TITLE 24 SPECIFICATIONS. <br />A 48"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />B 36"x36" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />C 36"x18" S.L. FROSTED GLASS W/D, DUAL GLAZING, VINYL FRAME, <br />TEMPERED GLASS <br />DOOR SCHEDULE <br />1 30"x80" HOLLOW CORE DOOR <br />2 36"x80" SOLID CORE ENTRY DOOR W/ TEMPERED GLASS <br />3 96"x80" CLOSET SLIDING DOOR <br />4 18"x80" EXTERIOR DOOR W/ LOUVERS AS DETAILED HEREON <br />BATHROOM NOTE <br />CEMENT, FIBER CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR <br />FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND <br />SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. <br />NE <br />W <br />FL <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />SHEET <br />A2 <br />REVISION <br />DATE BY <br />1 <br />2 <br />3 <br />PROJECT ENGINEER <br />BEN PHAN <br />10822 WOODWARD LN <br />GARDEN GROVE, CA 92840 <br />TEL: (714) 251 4537 <br />SD <br />LEGEND <br />GFCI RECEPTACLE <br /> WR GFCI WEATHER RESISTANT RECEPTACLE <br />TAMPER RESISTANT RECEPTACLE, 120V SINGLE PHASE, 20A, <br /> CONTROLLED BY ARC-FAULT CIRCUIT INTERRUPTER (AFCI) <br />240V, 30A (10 AWG COPPER) DEDICATED OUTLET FOR WATER HEATER <br />CEILING-MOUNT RECESS LIGHT <br />OUTDOOR WALL-MOUNT LIGHT FIXTURE W/ PHOTOCELL & MOTION SENSOR <br /> $LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $3 3-WAY LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $vs VACANCY SENSOR LIGHT SWITCH <br /> $W/D WASHER/DRYER DISCONNECT SWITCH, 20A, INSTALL PER MANU. SPECS. <br />EXHAUST FAN (100 CFM MINIMUM) W/ HUMIDITY CONTROL <br />IN-SINK DISPOSAL <br />AIR REGISTER ON CEILING <br />SMOKE DETECTOR <br />CARBON MONOXIDE DETECTOR <br />4" DRYER VENT W/ DAMPER, TERMINATED 30" ABOVE F.F. ON OUTSIDE WALL <br />4" DRYER EXHAUST VENT W/ APPROVED WALL STRAP, TERMINATED ABOVE <br />ROOF THROUGH APPROVED FLASHING, VENT 14' LONG MAX., 2 ELBOWS MAX. <br /> W/H 240V-50 GAL. WATER HEATER TANK, RHEEMTM MODEL XE50T10H22U <br /> W CLOTHES WASHER <br /> D CLOTHES DRYER <br />HOSE BIB WITH ANTI-SIPHON VALVE <br />AIR RETURN ON CEILING <br />ROOF-MOUNT ATTIC VENT <br />IAQ FAN (PER TITLE 24), 80 CFM MINIMUM <br />CO <br />AGING-IN-PLACE NOTES <br />A. REINFORCEMENT FOR GRAB BARS - AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED <br />WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. <br />1) REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE <br />ENFORCING AGENCY. <br />2) REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2 INCH BY 7-1/4 INCH <br />ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. <br />REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR, <br />FLUSH WITH THE WALL FRAMING. <br />3) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE <br />SIDE WALL AND THE BACK WALL. <br />4) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5) BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END <br />OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB <br />BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB <br />RIM. <br />6) WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A <br />GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY <br />OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. <br />7) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER <br />ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN <br />FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />8) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS <br />SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR <br />AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />9) BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION <br />OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF <br />FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY <br />THE ENFORCING AGENCY. <br />10) REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS <br />INSTALLED ON CONCRETE SLAB FLOORS. <br />B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/OR DRAWINGS IDENTIFYING THE <br />LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL <br />IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC <br />R327.1.1.1) <br />C. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS - ELECTRICAL RECEPTACLE <br />OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR <br />CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES <br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2). EXCEPTIONS: <br />1) DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING <br />FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />2) RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE <br />DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A <br />WINDOW, IS LESS THAN 15 INCHES. <br />D. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 <br />INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL <br />BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE <br />INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD <br />DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 <br />MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR <br />CONTROL. (CRC R327.1.4) <br />OW <br />N <br />E <br />R <br />KR <br />Y <br />S <br />T <br />I <br />E <br /> <br />V <br />O <br />N <br />G <br />TE <br />L <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />9 <br />0 <br />2 <br /> <br />7 <br />0 <br />7 <br />2 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />: <br /> <br />5 <br />1 <br />0 <br /> <br />S <br /> <br />A <br />R <br />A <br />P <br />A <br />H <br />O <br /> <br />D <br />R <br />AD <br />U <br />: <br /> <br />5 <br />1 <br />0 <br /> <br />S <br /> <br />A <br />R <br />A <br />P <br />A <br />H <br />O <br /> <br />D <br />R <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />DATE 11/05/2023 <br />NE <br />W <br /> <br />A <br />T <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />4 <br />7 <br />3 <br /> <br />S <br />F <br />AD <br />U <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br />(1 <br /> <br />B <br />E <br />D <br />R <br />O <br />O <br />M <br /> <br />- <br /> <br />1 <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />) <br />WALL W/ 5/8" TYP.X DRYWALL TO <br />ROOF SHEATHING ON BOTH SIDES <br />WATER HEATER - DRYER - <br />F.A.U. DOOR DETAIL <br />N.T.S. <br />18" <br />18" <br />PER PLAN <br />100 SQ. IN. MIN. ON EACH LOUVER <br />FOR COMBUSTION AIR <br />(1 SQ. IN. PER 1,000 BTU/HR) <br />80" <br />ELEC. BOX HEIGHT <br />N.T.S. <br />15" <br />MIN. <br />48" <br />MAX. <br />F.F. <br />510 S Arapaho Dr #2 <br />1011182015/9/2024