Laserfiche WebLink
PLASTER CREED <br />N.T.S.24 <br />23 <br />20 12 08 <br />19 15 11 07 <br />04 <br />03 <br />14 06 <br />13 05 <br />02 <br />0109 <br />INTERIOR NON-BEARING WALL <br />N.T.S. <br />(N) SLAB @ (E) GARAGE WALL <br />N.T.S.18 <br />PIPING THRU PLATE FRAMING <br />N.T.S. <br />PLATE SPLICING <br />N.T.S. <br />CONCRETE STEPS AND LANDING <br />N.T.S. <br />INTERIOR SLAB REPAIR DETAIL <br />N.T.S. <br />STUD NOTCHING/BORING LIMIT <br />N.T.S. <br />WALL FRAMING <br />N.T.S. <br />10 <br />DTC CLIP <br />2x BLKG. @ 24" O.C. <br />1/2" CLR. <br />DOUBLE PLATES <br />STUD WALL <br />JOIST OR <br />3 - 16d <br />RAFTER <br />JOISTS PARALLEL TO WALL <br />PER JST <br />JOISTS PERPENDICULAR TO WALL <br />STUD WALL <br />DTC CLIP <br />1/2" CLR.JST. OR RR <br />DOUBLE PLATES <br />(N) SLAB/FOOTING @ GARAGE DOOR <br />N.T.S. <br />INT. NON-BRG WALL @ CEILING <br />N.T.S. <br />18" MIN. <br />12" <br />EXISTING <br />EXISTING <br />(N) SLAB @ (E) GARAGE WALL <br />N.T.S. <br />EXISTING <br />SIMPSON HOLDDOWN W/ SSTB BOLT <br />N.T.S. <br />EAVE DETAIL (1-HOUR FIRE RATED) <br />N.T.S. <br />SECTION A-A <br />NOTE <br />SYSTEM NO.W-L-5001 <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) <br />T RATINGS - 3/4, 1 AND 1-1/2 HR (SEE ITEM 3) <br />L RATING AT AMBIENT - 2 CFM/SQ FT <br />L RATING AT 400 F - LESS THAN 1 CFM/SQ FT <br />1. WALL ASSEMBLY <br />A. STUDS <br />B. GYPSUM BOARD* <br />THE HOURLY F RATING OF THE FIRE-STOP SYSTEM IS 1 HR WHEN INSTALLED IN A 1-HR FIRE RATED WALL, AND 2 HR WHEN INSTALLED IN A 2-HR FIRE <br />RATED WALL. <br />2. THROUGH PENETRANTS <br />A. STEEL PIPE <br />B. COPPER TUBING <br />C. COPPER PIPE <br />3. PIPE COVERING* <br />PIPE AND EQUIPMENT COVERING <br />THE HOURLY T RATING OF THE FIRES-TOP SYSTEM IS 3/4 HR WHEN NOM. 1 IN. THICK PIPE COVERING IS USED. <br />THE HOURLY T RATING OF THE FIRE-STOP SYSTEM IS 1-HR AND 1-1/2 HR WHEN NOM 2 IN. THICK PIPE COVERING IS USED WITH 1-HR AND 2-HR FIRE <br />RATED WALLS, RESPECTIVELY. <br />4. FIRE-STOP SYSTEM <br />A. FILL, VOID OR CAVITY MATERIALS* - WRAP STRIP <br />3M COMPANY <br />B. FILL, VOID OR CAVITY MATERIALS* - CAULK OR SEALANT <br />3M COMPANY <br />STC-50 AND 1-HR FIRE RATED WALL <br />N.T.S. <br />RATED DUCT PENETRATION DETAIL <br />N.T.S. <br />2-2X CEILING JOISTS <br />@ OPENING <br />2-2X BLKG <br />AROUND EDGES <br />HU2x-2 HANGER <br />ATTIC OPENING DETAIL <br />N.T.S. <br />EXISTINGEXISTING <br />RAKE DETAIL <br />N.T.S. <br />A36 THREADED HOLDDOWN BOLTS <br />N.T.S. <br />SD-1 <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br />Date <br />Drawing Title <br />Project Number <br />DesignedDrawn <br />DRAWING NUMBER <br />Checked <br />ANY DISCREPANCIES. DO NOT SCALE DRAWINGS; USE FIGURED DIMENSIONS. <br />CONTRACTOR IS TO NOTIFY THE ENGINEER FOR CLARIFICATION OF <br />CALIFORNIA RELATING TO STRUCTURES AND BUILDINGS. <br />RULES, REGULATIONS AND ORDINANCES OF THE STATE OF <br />THE BEST OF MY KNOWLEDGE, THE SAME COMPLIES WITH THE <br />HAS BEEN PREPARED UNDER MY SUPERVISION AND THAT TO <br />I HEREBY CERTIFY THAT THE ENGINEERING ON THESE PLANS <br />NO. DATE REVISION <br />AD <br />U <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br />OW <br />N <br />E <br />R <br />: <br /> <br />K <br />R <br />Y <br />S <br />T <br />I <br />E <br /> <br />V <br />O <br />N <br />G <br />51 <br />0 <br /> <br />S <br /> <br />A <br />R <br />A <br />P <br />A <br />H <br />O <br /> <br />D <br />R <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />510 S Arapaho Dr #2 <br />1011182015/9/2024