Laserfiche WebLink
WH <br />EXT <br />1 P <br />WAITING <br />BARBER AREA <br />HALLWAY <br />VIP 1 <br />VIP 2 <br />BREAK ROOM <br />STORAGE <br />(E) RESTROOM <br />TACTILE EXIT SIGN SHALL BE <br />PROVIDED AT EVERY <br />EXTERIOR EXIT DOOR <br />4' - 0" <br />A2.2 <br />3 <br />AREA IDENTITY / EXITING WIDTH LEGEND <br />1 PATH OF TRAVEL (NUMBER INDICATES <br />OCCUPANT LOAD) <br />1 EXITING WIDTH SYMBOL <br />P PANIC HARDWARE (REQUIRED) <br />EGRESS PLAN NOTES <br />TACTILE EXIT SIGN PROVIDED AT EVERY <br />EXTERIOR EXIT DOOR <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />ALL EXIT DOORS SHALL COMPLY WITH SECTIN 1010.1 <br />SHOW THE PATH OF EXIT TRAVEL TO AND WITHIN EXITS. THE EXIT PATH <br />SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE <br />REQUIREMENTS OF SECTION 1013. EXIT SIGNS SHALL BE READILY <br />VISIBLE FROM ANY DIRECTION OF APPROACH. EXIT SIGNS SHALL BE <br />LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF <br />EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET FROM THE <br />NEAREST VISIBLE SIGN. (1013.1) <br />ALL REQUIRED EXITS SHALL BE MAINTED UNTIL ARRIVAL AT GRADE OR <br />THE PUBLIC WAY. (1006.3.1) <br />THE RATE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE <br />OF ONE OCCUPANT PER UNIT OF AREAS AS PRESCRIBED IN TABLE <br />1004.1.1 FOR AREAS WITHOUT FIXED SEATING THE OCCUPANT SHALL <br />NOT BE LESS THAN THE NUMBER DETERMINED BY DIVIDING THE FLOOR <br />AREA UNDER CONSIDERATION BY THE OCCUPANT PER UNIT AREA <br />FACTOR ASSIGNED TO THE OCCUPANCY AS SET FORTH HEREIN TABLE <br />1004.1.1 <br />ALL SYSTEMS TO BE ALTERED IN TENANT IMPROVEMENT SHALL <br />COMPLY WITH ENERGY REQUIREMENTS AND ALL COMPLIANCE FORMS <br />SUBMITTED TO THE BUILDING & SAFETY DEPARTMENT FOR ITS REVIEW. <br />THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE <br />ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE <br />MEANS OF EGRESS IS OCCUPIED. EMERGENCY LIGHTING FACILITIES <br />SHALL BE ARRANGED TO PROVIDE ILLUMINATION THAT IS AT LEAST AN <br />AVERAGE OF 1.0 FOOT CANDLE MEASURED ALONG THE PATH OF <br />EGRESS AT FLOOR LEVEL, (2016 CBC, SECTION 1006.4) <br />EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL <br />HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A <br />CONSPICUOUS PLACE NEAR THE MAIN EXIT OR EXIT ACCESS DOOR <br />WAY. (2016 CBC, SECTION 1004.3) <br />EGRESS NOTES <br />1. <br />2. <br />3. <br />4. <br />5. <br />PLACE A SIGN AT EVERY PUBLIC ENTRANCE AND AT EVERY MAJOR <br />JUNCTION ALONG OR LEADING TO AN ACCESSIBLE PATH OF TRAVEL <br />DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS <br />SHALL INDICATE THE DIRECTION TO ACCESSIBLE FACILITY ENTRANCES <br />AND COMPLY WITH CBC 11B-216.1, 703.1 <br />AN EGRESS DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO A <br />30# FORCE. THE DOOR SHALL SWING TO THE FULLY OPEN POSITION <br />WHEN AN OPENING FORCE NOT TO EXCEED 15 POUNDS IS APPLIED TO <br />THE LATCH SIDE. <br />THE OPENING FORCE FOR INTERIOR SIDE SWING DOORS WITHOUT <br />CLOSERS SHALL NOT EXCEED 5 POUNDS. <br />DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE <br />WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR <br />EFFORT. <br />ALL EXITS ARE EXISTING AND ACCESSIBLE TO PERSONS WITH <br />DISABILITIES AND SHALL MAINTAIN THRESHOLDS LESS THAN 1/2" <br />ABOVE ADJACENT FLOOR SURFACE. THE BOTTOM 10" OF ALL NEW <br />DOORS SHALL HAVE A SMOOTH SURFACE. HARDWARE TO BE SINGLE <br />ACTION PLACED BETWEEN 30-40" A.F.F. WITH OPERATING PRESSURE <br />OF 5 LBS. MAXIMUM. <br />ALL AISLES AND WALKWAYS BETWEEN FIXED FURNITURE <br />CABINETRY, EQUIPMENT, AND WALLS FOR NORMAL PATH OF <br />ACCESS SHALL BE 3'-0" CLEAR MINIMUM UNLESS NOTED AND/OR <br />DIMENSIONED. <br />PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT ALL <br />LOCATIONS AS MARKED ON PLANS. SYMBOLS SHALL BE A WHITE <br />FIGURE ON BLUE BACKGROUND MOUNTED AT 60" A.F.F. <br />F FIRE EXTINGUISHER LOCATION <br />EXIT SIGN SYMBOL <br />EXT <br />1 EXIT WIDTH: <br />21 PERSON X (0.2) INCHES PERSON = 4.2" <br />NOTE: EXISTING (1) EXIT DOOR OF WIDTH AT FRONT : 72" ( COMPLIED) <br />WAITING <br />BARBER AREA <br />HALLWAY <br />VIP 1 <br />VIP 2 <br />BREAK ROOM <br />STORAGE <br />(E) RESTROOM <br />10' - 0" <br />10' - 0" <br />10' - 0" <br />10' - 0" <br />10' - 0" <br />10' - 0" <br />8' - 0" <br />2 <br />2 <br />DOWNLIGHT 4-INCH ROUND <br />ELECTRICAL SCHEDULE <br />EXT <br />SUPPLY REGISTER <br />SURFACE MOUNTED <br />EMERGENCY EXIT LIGHT & SIGN <br />W/ 90 MINUTES BACK UP. <br />RETURN REGISTER <br />SYMBOL DESCRIPTION <br />LIGHTING <br />EXISTING CEILING TO REMAIN - <br />NO MODIFICATIONS <br />Project No. <br />Date: <br />Design by: <br />TRINH HA, M. Arch <br />Sheet No. <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />f <br />o <br />r <br />: <br /> <br />Hu <br />n <br />t <br />i <br />n <br />g <br />t <br />o <br />n <br /> <br />E <br />x <br />e <br />c <br />u <br />t <br />i <br />v <br />e <br /> <br />P <br />a <br />r <br />k <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />P <br />h <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />9 <br />2 <br />8 <br />- <br />2 <br />0 <br />0 <br />6 <br />16 <br />1 <br />6 <br />8 <br /> <br />B <br />e <br />a <br />c <br />h <br /> <br />B <br />l <br />v <br />d <br />, <br /> <br />S <br />t <br />e <br /> <br /># <br /> <br />2 <br />0 <br />1 <br />C <br />We <br />b <br />s <br />i <br />t <br />e <br />: <br /> <br />H <br />o <br />m <br />e <br />T <br />o <br />p <br />H <br />o <br />m <br />e <br />. <br />c <br />o <br />m <br />Hu <br />n <br />t <br />i <br />n <br />g <br />t <br />o <br />n <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />4 <br />7 <br />Em <br />a <br />i <br />l <br />: <br /> <br />i <br />n <br />f <br />o <br />@ <br />H <br />o <br />m <br />e <br />T <br />o <br />p <br />H <br />o <br />m <br />e <br />. <br />c <br />o <br />m <br />4/4/2025 <br />7:52:13 AM <br />24-14 <br />A2.2 <br />ADA PATH OF <br />TRAVEL. <br />REFLECTED <br />CEILING PLAN. <br />FLOOR <br />PLAN-RESTROOM <br />51 <br />2 <br />7 <br /> <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br /> <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />G <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />BA <br />R <br />B <br />E <br />R <br /> <br />S <br />H <br />O <br />P <br /> 1/4" = 1'-0"2 ADA PATH OF TRAVEL. <br />TOTAL = 21 OCCUPANTS LESS THAN 50. <br />EXIT REQUIRED:1 <br /> PROVIDED:1 <br />OCCUPANT LOAD CALCULATION (TABLE 1004.5) <br />NAME AREA OCCUPANT LOAD <br />FACTORE OCCUPANT LOAD <br />WAITING 85 SF 15 6 <br />BARBER AREA 444 SF 150 3 <br />HALLWAY 153 SF 150 1 <br />VIP 1 92 SF 150 1 <br />VIP 2 135 SF 150 1 <br />BREAK ROOM 104 SF 15 7 <br />STORAGE 129 SF 300 1 <br />(E) RESTROOM 50 SF 150 1 <br />21 <br /> 1/4" = 1'-0"1 REFLECTED CEILING PLAN . <br /> 1/2" = 1'-0"3 FLOOR PLAN - RESTROOM. <br />REVISIONS <br />NO.DATE BY <br />1 12/26/2024 SUBMITTAL <br />2 02/28/2025 2ND. SUBMITTAL <br />4 04/04/2025 4TH. SUBMITTAL <br />NOTE: EXISTING CEILING TO REMAIN - NO MODIFICATIONS <br />2 <br />2 <br />2 <br />2 <br />4 <br />5127 W Edinger Ave <br />#G5/8/2025