Laserfiche WebLink
(N) KITCHEN <br />9'-00" CLG <br />9'-00" CLG <br />(N) BED 3 <br />9'-00" CLG(N) BED 2 <br />9'-00" CLG <br />(N) BA2 <br />9'-00" CLG <br />(N) BED 1 <br />9'-00" CLG <br />(N) PORCH <br />9'-00" CLG <br />25 <br />' <br />9' <br />- <br />3 <br />" <br />6' <br />- <br />6 <br />" <br />9' <br />- <br />3 <br />" <br />19'-61 <br />2"10' <br />41'-7" <br />13 <br />' <br />- <br />4 <br />" <br />11 <br />' <br />- <br />8 <br />" <br />25 <br />' <br />15'-11 <br />2"10'-10"11'-3" <br />41'-7" <br />5'-21 <br />2"6'-10" <br />(N) LIVING <br />TV <br />4'x2' <br />CABINET <br />4'-5" <br />4' <br />SD <br />EF <br />2 <br />SD <br />SD SD <br />EF 1 <br />EF <br />1 (N) TANKLESS <br />W/H <br />(N) LAUNDRY <br />ROOM <br />SD <br />HB <br />AFCI <br />GF <br />C <br />I <br />AF <br />C <br />I <br />GF <br />C <br />I <br />AF <br />C <br />I <br />OS <br />GF <br />C <br />I <br />AF <br />C <br />I <br />GF <br />C <br />I <br />AF <br />C <br />I <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GF <br />C <br />I <br />30" <br />1,024 SI <br />30" <br />1,024 SI <br />(N) DETACHED ADU <br />1,000 S.F. <br />522 S Raitt St #2 <br />(N) LANDING CONCRETE <br />3' x 4' <br />GF <br />C <br />I <br />AF <br />C <br />I <br />GF <br />C <br />I <br />AF <br />C <br />I <br />6'-5" <br />GFCI <br />GF <br />C <br />I <br />GFCI <br />(N) ATTIC FAU#1 <br />22"x30" <br />2'-6" <br />1' <br />- <br />1 <br />0 <br />" <br />3' <br />AFCI <br />AFCI <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />W.P <br />GFCI <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCIAFCI <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AFCIW.P <br />GFCI AF <br />C <br />I <br />AF <br />C <br />I <br />GFCI <br />AFCI <br />GFCI <br />AF <br />C <br />I <br />AFCI <br />CO(N) ATTIC <br />ACCESS <br />SECTION KEY NOTES <br />10 <br />1 <br />2 <br />3 <br />7 <br />5 <br />9 <br />12 <br />6 <br />11 <br />4 <br />13 <br />8 <br />(N) ROOF SHEATHING W/RADIANT BARRIER <br />(N) 2x ROOF RAFTER. PER. STRUCTURE PLAN <br />(N) 2X4 STUD WALL <br />(N) R-15 WALL INSULATION <br />(N) 1/2" GYPSUM BOARD <br />(N) CEILING JOIST <br />(N) CONCRETE FOOTING <br />(N) CLASS "A" COMPOSITION SHINGLE. (ICC ESR-1475) <br />(N) 7/8" THK. (3) COAT STUCCO SYSTEM TYP. O/ <br />MET. LATH AND BUILDING PAPER <br />(N) 2X P.T.D.F SILL PLATE <br />(N) R-30 CEILING INSULATION <br />(N) CONCRETE SLAB <br />(N) 1/2" GYPSUM BOARD <br />14 (N) ATTIC LIGHT <br />15 (N) FURNACE <br />16 (N) R-13 INSULATION <br />LEGEND <br />WINDOW CALL OUT <br />DOOR CALL OUT <br />CEILING MOUNTED LIGHT HIGH <br />EFFICACY <br />WALL MOUNTED LIGHT HIGH EFFICACY <br />SINGLE POLE LIGHT SWITCH <br />FLUORESCENT <br />HIGH EFFICACY <br />PHOTOCELL <br />TEMPERED SAFETY GLAZING <br />WINDOW MEETS EMERGENCY EGRESS REQUIREMENTS 44" <br />MAX TO SILL, MIN 24" CLR HT., 20" CLR WIDTH, 5.7 SQ.FT. MIN. <br />NET CLEAR OPENING. <br />(N) 30" X 30" ATTIC ACCESS <br />W/30" MIN HEADROOM ABOVE <br />4" DIA DRYER VENT <br />EXHAUST FAN <br />W/ HUMIDSTAT CONTROL. CAPABLE OF PROVIDING 30 <br />CFM. DUCTED TO TERMINATE TO THE OUTSIDE OF <br />BUILDING. ENERGY STAR COMPLIANT <br />100 AMP ELECTRICAL SUB PANEL <br />DIMMER SWITCH <br />CARBON MONOXIDE ALARMS <br />OUTLET 110 VOLTS <br />(TEMPERED RESISTANT OUTLETS REQUIRED IN KITCHEN, <br />BEROOMS, DENS, FAMILY ROOMS, DINING ROOMS, LIVING <br />ROOMS, PARLORS, LIBRARY, SUNROOMS AND RECREATION <br />ROOMS) <br />DS <br />S <br />F <br />H.E. <br />P.C. <br />WASHERW <br />GAS DRYERD <br />DBL. DUPLEX RECEPTACLE <br />AFCI DBL. DUPLEX RECEPTACLE <br />GFCI DBL. DUPLEX RECEPTACLE <br />WATER PROOF DBL. <br />DUPLEX RECEPTACLE <br />(220V) DUPLEX RECEPTACLE <br />SWITCH W/OCCUPANCY <br />SENSOR <br />HOSE BIB. <br />SD <br />CO <br />HARD-WIRED SMOKE ALARM W/BATTERY BACK-UP. <br />LOCATE SMOKE ALARM IN BEDROOMS AND HALLWAYS. <br />ALL NEW SMOKE ALARMS ARE LISTED AND LABELED <br />ACCORDING TO UL 217. SMOKE ALARMS SHALL BE <br />INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION <br />OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE <br />INDIVIDUAL UNIT. <br />CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH <br />BATTERY BACKUP AND INTERCONNECTED SO THAT THE <br />ACTIVATION OF ONE ALARMS SHALL ACTIVATE ALL OTHER <br />ALARMS IN THE DWELLING UNIT. <br /> CONTROLLED BY HUMIDSTAT. HUMISTAT CONTROLS SHALL BE <br />CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY <br />RANGE OF 50 TO 80 PERCENT. <br />S <br />ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON <br />BACKFLOW PREVENTION DEVICE <br />EXHAUST FAN (MIN. RATE OF 100 CFM) <br />CEILING MOUNTED LIGHT HIGH <br />EFFICACY (WET LOCATION) <br />ELECTRICAL "J" BOX <br />CHANDELIER <br />1. PERMANENTLY INSTALLED LUMINARIES: <br /> a. ALL FIXTURES ARE HIGH EFFICACY. <br /> b. BATHROOMS, LAUDRY ROOMS, GARAGES AND UTILITY ROOMS REQUIRED <br />OCCUPANT SENSOR. <br />2. HIGH EFFICACY LUMINAIRES SHALL BE EITHER FLOURESENT OR LED LIGHT <br />FIXTURES <br />3. HIGH EFFICACY LUMINARES MUST BE PIN BASED. <br />LIGHT FIXTURES HIGH EFFICACY NOTES : <br />-- <br />-- <br />F <br />HB <br />T <br />E <br />OS <br />AFCI <br />GFCI <br />W.P <br />J <br />E <br /> LOUVER DOOR <br />COMBUSTIBLE AIR FOR CENTRAL FURNACE <br />BTU/H = 40,000.00 <br />1 SQ. IN. REQUIRED FOR EVERY 1,000 BTU/H <br />REQUIRED VENT AREA = 40 SQ. IN. <br />LOUVER AREA = 96 SQ. IN <br />FREE AREA = 75% FREE AREA FOR METAL LOUVER <br />NET FREE AREA = 96 * 0.75 = 72 SQ. IN. EACH LOUVER <br />(1) LOUVER - FREE AREA = 72 SQ. IN <br />COMBUSTIBLE AIR FOR CENTRAL FURNACE <br />BTU/H = 48,000.00 <br />1 SQ. IN. REQUIRED FOR EVERY 1,000 BTU/H <br />REQUIRED VENT AREA = 48 SQ. IN. <br />LOUVER AREA = 2X8"X12" = 192 SQ. IN <br />FREE AREA = 25% FREE AREA FOR WOOD LOUVER <br />NET FREE AREA = 192 * 0.25 = 48 SQ. IN. <br />12"X8" METAL LOUVER WITH MINIMUM 14" MESH <br />12"X8" METAL LOUVER WITH MINIMUM 14" MESH <br />ELECTRICAL PLAN <br />BASEMENTS, HABITABLE ATTICS AND SLEEPING ROOMS SHALL HAVE AT LEAST ONE <br />OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. (R310.1): <br />A. MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. <br />B. MINIMUM 5 SQUARE FEET FOR GRADE-FLOOR OPENINGS. SEE DEFINITION OF "GRADE <br />FLOOR OPENING." <br />C. MINIMUM NET CLEAR OPENING WIDTH OF 20 INCHES. <br />D. MINIMUM NET CLEAR HEIGHT OF 24 INCHES. <br />E. CLEAR OPENING OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. <br />EMERGENCY EGRESS <br />NOTE: RESIDENTIAL ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE <br />NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES <br />SMOKE & CO2 DETECTOR NOTES: <br />1.PROVIDE UL 217 RATED SMOKE ALARMS IN EACH SLEEPING ROOM, OUTSIDE EACH <br />SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, AND AT <br />EACH ADDITIONAL FLOOR OR BASEMENT LEVEL. SMOKE ALARMS MAY BE BATTERY <br />OPERATED AND NOT INTERCONNECTED. <br />2.UL 2034/2075 RATED CARBON MONOXIDE ALARMTHE CARBON MONOXIDE ALARM MAY BE <br />BATTERY OPERATED AND NOT INTERCONNECTED. <br />SYMBOL HEATING <br />HVAC SYSTEM <br />MIN. EFF.COOLING THERMOSTAT REMARKS <br />AC <br />1 CENTRAL AIR 95% AFUE <br />CENTRAL <br />CONDITIONER <br />14.0 <br />SEER SETBACK <br />MIN. EFF. <br />” <br />SCALE: 1/4"=1' <br />SECTION2 <br />SCALE: 1/4"=1' <br /> ELECTRICAL PLAN1 <br />1 <br />1 <br />1 <br />1 <br />WINDOW SCHEDULE <br />FRAME GLAZING HD. HGT.U-FACTOR SHGC <br />ALL WINDOW VINYL FRAME DOUBLE PANE 6'-8" NOM.0.25 0.32 <br />PLUMBING FIXTURE SCHEDULE <br />ITEM MINIMUM <br />CONNECTIONS REMARK <br />WATER CLOSET <br />LAVATORY <br />SHOWER <br />TUB <br />KITCHEN FAUCET <br />S.S.V.C.W.H.W. <br />4"3"1/2"N.A.1.28 gallon/flush <br />1.2 gpm <br />1.8 gpm <br />1.8 gpm <br />1-1/4"1-1/4"1/2"1/2" <br />2" <br />2" <br />2" <br />1-1/2" <br />1-1/2" <br />1-1/2" <br />1/2" <br />1/2" <br />1/2" <br />1/2" <br />1/2" <br />1/2" <br />1 <br />NORTH <br />NORTH <br />1 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />. <br />D <br />. <br />U <br /> <br />1 <br />. <br />0 <br />0 <br />0 <br /> <br />S <br />. <br />F <br />. <br />52 <br />2 <br /> <br />S <br /> <br />R <br />a <br />i <br />t <br />t <br /> <br />S <br />t <br />. <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />52 <br />2 <br /> <br />S <br /> <br />R <br />a <br />i <br />t <br />t <br /> <br />S <br />t <br /> <br /># <br />2 <br />. <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SCALE AS NOTED <br />DRAWN BY - <br />CHECKED BY - <br />PLAN DATE <br />PRINT DATE <br />PROJECT No - <br />-- <br />REV. DESCRIPTION DATE <br />DESIGNER <br />Fidsconstruction2020@gmail.com <br />INTERIOR DESIGN STUDIO <br />714-988-5688 <br />FIDS STUDIO <br />11352 RENAISSANCE WAY STANTON, <br />CA 90680 UNITED STATES <br />ENGINEER <br />PROJECT <br />SHEET TITLE <br />SHEET No. <br />1 REVISION 05.04.24 <br />- <br />2 REVISION 06.07.24 <br />VAN LY <br />11352 RENAISSANCE WAY STANTON, <br />CA 90680 UNITED STATES <br />vanly@fidsstudio.com <br />(714) 858-7881 <br />A-4 <br />2 <br />1 <br />1 <br />PERMIT ISSUED STAMP <br />2 <br />522 S Raitt St & #2 - <br />101118250-518/19/2024