Laserfiche WebLink
N <br />KE <br />L <br />L <br />Y <br /> <br />N <br />G <br />U <br />Y <br />E <br />N <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />52 <br />5 <br /> <br />S <br /> <br />M <br />A <br />R <br />I <br />N <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />Project Name & Address <br />Sheet Number <br />E 1.3 <br />Sheet Name <br />DRAWN BY <br />YG <br />CO <br />U <br />N <br />T <br />Y <br />- <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DATE: 04/13/2023 <br />AH <br />J <br />- <br /> <br />O <br />R <br />A <br />N <br />G <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />32203 VIA BENABARRE, TEMECULA <br />CA USA 92592 <br />CSLB # : 978840 <br />EMAIL: <br />JEREMY@POWERCONSULTATIONS.COM <br />TIME SAVER ELECTRIC <br />WARNING LABELS <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />52 <br />5 <br /> <br />S <br /> <br />M <br />A <br />R <br />I <br />N <br />E <br /> <br />S <br />T <br />(N)PV ARRAY <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 <br />ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED <br />BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING <br />EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR <br />WIRING METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT <br />SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />PER CODE(S): CEC 2022: 690.35(F), NEC 2014: <br />690.35(F), NEC 2011: 690.35(F) <br />WARNING! <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN SERVICE <br />PANEL. <br />PER CODE(S): NEC 2014: 705.12(D)(3), <br /> NEC 2011: 705.12(D)(4) <br />ELECTRICAL SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), ENPHASE ENVOY ENCLOSURE <br />(IF APPLICABLE). <br />PER CODE(S): CEC 2022: 690.15, <br />NEC 2014: 690.5(C), NEC 2011: 690.5(C) <br />! <br />ELECTRICAL SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />WARNING ! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 690.17(B), <br />NEC 2014: 690.17(E), NEC 2011: 690.17(4) <br />WARNING ! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />INVERTER OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B), <br />NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(D)(2)(3)(c), NEC <br />2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH <br />TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL <br />BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2022: 690.13, NEC 2014: 690.31(G)(3), <br />690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: <br />605.11.1.4 <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.53, NEC 2014: 690.54, NEC 2011: 690.54 <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 61.71 AMPS <br /> 240 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />(E)METER/MAIN COMBO.PANEL <br />(N)AC COMBINER <br />PANEL <br />(N)100A NON-FUSED AC DISCONNECT <br />Signed 07/11/2023 <br />525 S Marine St <br />07/28/23