My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
525 S Marine St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Marine St
>
525 S Marine St
>
525 S Marine St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:23 PM
Creation date
6/1/2025 12:07:57 PM
Metadata
Fields
Template:
Plan
Permit Number
20280256
102115780
Full Address
525 S Marine St
Document Relationships
102115780 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Marine St\525 S Marine St
20280256 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Marine St\525 S Marine St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 of 2 <br />D. Solar Panel Anchorage <br />1. The solar panels shall be mounted in accordance with the most recent Ecofasten Rock it <br />installation manual. If during solar panel installation, the roof framing members appear unstable or <br />deflect non-uniformly, our office should be notified before proceeding with the installation. <br />2.The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as <br />identified in the National Design Standards (NDS) of timber construction specifications. Based on <br />a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the <br />design withdrawal force (demand). Considering the variable factors for the existing roof framing <br />and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of <br />2½” embedment will be adequate and will include a sufficient factor of safety. <br />3.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of <br />the roof, the panel supports shall be placed no greater than 72” on centers. <br />4.Panel supports connections shall be staggered to distribute load to adjacent framing members. <br />Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing <br />roof system will adequately support the additional loading imposed by the solar system. This evaluation is <br />in conformance with the 2022 CBC, current industry standards, and is based on information supplied to us <br />at the time of this report. <br />Should you have any questions regarding the above or if you require further information do not hesitate to <br />contact me. <br />Very truly yours, <br />Scott E. Wyssling, PE <br />California License No. 83664 <br />Signed 07/11/2023 <br />525 S Marine St <br />07/28/23
The URL can be used to link to this page
Your browser does not support the video tag.