Page 2 of 2 <br />D. Solar Panel Anchorage <br />1. The solar panels shall be mounted in accordance with the most recent Ecofasten Rock it <br />installation manual. If during solar panel installation, the roof framing members appear unstable or <br />deflect non-uniformly, our office should be notified before proceeding with the installation. <br />2.The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as <br />identified in the National Design Standards (NDS) of timber construction specifications. Based on <br />a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the <br />design withdrawal force (demand). Considering the variable factors for the existing roof framing <br />and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of <br />2½” embedment will be adequate and will include a sufficient factor of safety. <br />3.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of <br />the roof, the panel supports shall be placed no greater than 72” on centers. <br />4.Panel supports connections shall be staggered to distribute load to adjacent framing members. <br />Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing <br />roof system will adequately support the additional loading imposed by the solar system. This evaluation is <br />in conformance with the 2022 CBC, current industry standards, and is based on information supplied to us <br />at the time of this report. <br />Should you have any questions regarding the above or if you require further information do not hesitate to <br />contact me. <br />Very truly yours, <br />Scott E. Wyssling, PE <br />California License No. 83664 <br />Signed 07/11/2023 <br />525 S Marine St <br />07/28/23