Laserfiche WebLink
Page 4 <br /> <br />Faults <br /> <br />No active faults are known to exist within or near the site. The probability of primary <br />surface rupture or deformation at the site is, therefore, considered very low. <br /> <br />The site is not designated to be located within the Special Studies/Earthquake Zone under <br />the Alquist-Priolo Special Studies Act. <br /> <br />Liquefaction Potential <br /> <br />Based on the State of California SEISMIC HAZARD ZONES Map, Anaheim <br />Quadrangle, the subject site is located within a potential liquefaction zone. Therefore, the <br />owner(s) of this property should be aware of the risks associated with the potential <br />liquefaction such as structural distress due to the potential differential settlement caused <br />by the potential liquefaction. (A strengthened foundation system has been recommended <br />to be used for the proposed new structure to reduce the potential effects due to the <br />potential seismic settlements). <br /> <br />Potential Consequences of Liquefaction or Secondary Liquefaction Included Hazards <br /> <br />Potential consequences of liquefaction or secondary liquefaction included hazards <br />generally consist of differential settlement (vertical deformations), lateral <br />movement/lateral spreading (horizontal deformations), oscillation, and reduction in <br />foundation soil-bearing capacity (bearing failure). <br /> <br />A sloping condition or drainage or stream channel does not exist at the site; therefore, <br />lateral movement/lateral spreading, oscillation, etc. due to potential liquefaction are not <br />anticipated to be credible hazards for the proposed new structure. <br /> <br />We believe if the area would be “liquefied” in the future due to a very strong earthquake, <br />the potential damage to the proposed new structure which will be properly structurally <br />designed in accordance with the new up-to-date codes would be much less severe than <br />the existing on-site structures and surrounding existing houses which have been <br />previously structurally designed based on old codes (which are much less stringent than <br />the current new codes). However, the owner(s) of this property should be aware of <br />the potential damage to the new structure due to liquefaction. <br /> <br />In summary, it should be recognized that structural mitigation may not reduce the <br />potential of the soils to liquefy during an earthquake; and there will remain some risk that <br />the new structure could still suffer damage if liquefaction occurs, during a very strong <br />earthquake. <br /> <br />Note: In accordance with the California Geological Survey (CGS), Special Publication <br />(SP) 117A, a detailed site-specific liquefaction study is not required for this project, since <br />the proposed new dwelling structure is not exceeding two stories and is not part of a <br />development of four or more dwelling units. <br />5604 W Highland St & #2 - <br />101119017-1811/19/2024