Page 6 <br /> <br />should have a very low expansion potential and should be geotechnically observed/tested <br />and accepted by the geotechnical consultant prior to using at the site. In general, grading <br />at the site should be performed in accordance with the requirements of the City and under <br />the geotechnical observation and testing of the project geotechnical consultant. The <br />compaction criterion for fill and backfill materials is a minimum of 90% of the maximum <br />density determined in accordance with ASTM Test Method D1557. <br /> <br />Temporary Excavations <br /> <br />In general, temporary excavations should be performed in accordance with OSHA <br />requirements. In general, care should be taken during excavation near an existing <br />structural object, if any to ensure no damage is done to the existing object. <br /> <br />The above temporary excavation recommendations can be changed by the geotechnical <br />consultant based on conditions to be exposed in the field during excavations. <br /> <br />BUILDING FOUNDATION DESIGN GUIDELINES <br /> <br />Geotechnical Parameters For Structural Design <br /> <br />For conservative purposes, the following “code” values (2019 CBC, Table 1806.2 <br />Material Class 5) can be used for structural design, as needed. <br /> <br />a. Allowable vertical bearing earth pressure: 1,500 psf. <br /> <br />An increase of one-third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br /> <br />b. Lateral bearing passive earth pressure: 100 psf. per foot into competent materials <br />below the finished ground surface. <br /> <br />An increase of one third is permitted when using the alternative load <br />combinations that include wind or earthquake loads. <br /> <br />c. Lateral Sliding Resistance: cohesion = 130 psf. <br /> <br />The cohesion value is to be multiplied by the contact area. <br /> <br />In no case shall the lateral sliding resistance exceed one-half the dead load. <br /> <br />d. Soil unit weight: 120 pcf. <br /> <br />New Building Footings <br /> <br />5604 W Highland St & #2 - <br />101119017-1811/19/2024