My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
613 W Tribella Ct - 101116079- DL - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tribella Crt
>
613 W Tribella Crt
>
613 W Tribella Ct - 101116079- DL - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 10:07:04 AM
Creation date
6/1/2025 12:08:04 PM
Metadata
Fields
Template:
Plan
Permit Number
101116079
Full Address
613 W Tribella Crt
Document Relationships
101116079 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tribella Crt\613 W Tribella Crt
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SunPower® InvisiMount | Residential Mounting System <br />Simple and Fast Installation <br /> Integrated module-to-rail grounding <br /> Pre-assembled mid and end clamps <br /> Levitating mid clamp for easy placement <br /> Mid clamp width facilitates consistent, even <br />module spacing <br /> UL 2703 Listed integrated grounding <br />Flexible Design <br /> Addresses nearly all sloped residential roofs <br />ȏ 'HVLJQLQODQGVFDSHDQGSRUWUDLWZLWKXSWRɒ <br />rail span <br /> Pre-drilled rails and rail splice <br /> Rails enable easy obstacle management <br />Customer-Preferred Aesthetics <br /> Best-in-class system aesthetics <br /> Black anodized components <br />ȏ /RZSURȴOHPLGFODPSVDQGFDSSHGȵXVK <br />end clamps <br />Part of Superior System <br /> Best-in-class system reliability and aesthetics <br /> Optional URRIWRSWUDQVLWLRQȵDVKLQJUDLO <br /> mounted J-box, and wire management rail clips <br /> Combine with SunPower modules and <br />mySunPower® monitoring app <br />Elegant Simplicity <br />SunPower® InvisiMount is a SunPower-designed <br />rail-based mounting system. The InvisiMount system <br />addresses residential sloped roofs and combines faster <br />LQVWDOODWLRQWLPHGHVLJQȵH[LELOLW\DQGVXSHULRUDHVWKHWLFV <br />&ODVVLFΖQYLVL0RXQWLVVSHFLȴFDOO\HQYLVLRQHGDQGHQJLQHHUHG <br />to pair with SunPower modules; Universal InvisiMount <br />is compatible with all module possibilities. The resulting <br />V\VWHPOHYHODSSURDFKDPSOLȴHVWKHLQVWDOODWLRQDQG <br />DHVWKHWLFEHQHȴWVȃIRUKRPHRZQHUVDQGIRULQVWDOOHUV <br />sunpower.com <br />Datasheet <br />SunPower® InvisiMount | Residential Mounting System <br />InvisiMount Component Details <br />Component Classic InvisiMount Universal InvisiMount Weight <br />Mid clamp Black oxide stainless steel 300 series Black anodized aluminum 6000 series 63 g (2.2 oz) TBD <br />End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) TBD <br />Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) <br />Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) <br />Rail bolt M10-1.5 × 25 mm; custom T-head SS304 18 g (0.63 oz) <br />Rail nut M10-1.5; DIN 6923 SS304 nominal <br />Ground lug <br />assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) <br />Row-to-row <br />grounding clip SS 301 with SS 304 M6 bolts n/a 75 g (2.6 oz) <br />Row-to-row <br />grounding <br />jumper <br />Stainless steel 300 series TBD <br />Row-to-row <br />spacer Black POM-grade plastic n/a 5 g (0.18 oz) <br />Roof Attachment BOM <br /> InvisiMount Comp Shingle Attachment with Pegasus <br /> InvisiMount Flat Tile Replacement Attachment with Pegasus <br /> InvisiMount S-Tile Replacement Attachment with Pegasus <br /> InvisiMount W-Tile Replacement Attachment with Pegasus <br />InvisiMount Operating Conditions <br />Temperature ȫr&WRr&ȫr)WRr) <br />Roof Attachment Hardware Warranties <br />Refer to roof attachment hardware manufacturers <br />documentation. <br />ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV <br />Warranties 25-year product warranty <br /> \HDUȴQLVKZDUUDQW\ <br />&HUWLȴFDWLRQV UL 2703 Listed <br /> Class A Fire Rated <br />Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. <br />© 2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. <br />$OORWKHUWUDGHPDUNVDUHWKHSURSHUW\RIWKHLUUHVSHFWLYHRZQHUV6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH <br />InvisiMount Components <br />Module¹ / Mid Clamp and Rail <br />Mid Clamp <br />End Clamp <br />Rail and Rail Splice <br />Ground Lug Assembly <br /> Module¹ / End Clamp and Rail <br />sunpower.com <br />509506 RevF <br />¹ With Classic InvisiMount, a module frame that is compatible with the InvisiMount system is required for hardware interoperability; modules without this frame may be used with Universal InvisiMount. <br />² SunPower recommends that all Equinox, InvisiMount, and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in <br />this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed <br />InvisiMount Component LRFD Capacities² <br /> Classic <br />Mid clamp <br />Uplift 664 lbf <br />Shear 540 lbf <br /> Universal <br />Mid clamp <br />Uplift TBD <br />Shear TBD <br /> Classic <br />End clamp <br />Uplift 899 lbf <br />Shear 220 lbf <br /> Universal <br />End clamp <br />Uplift TBD <br />Shear TBD <br />Rail <br />Moment: upward 548 lbf-ft <br />Moment: downward 580 lbf-ft <br />Rail splice <br />Moment: upward 548 lbf-ft <br />Moment: downward 580 lbf-ft <br />L-foot <br />Uplift 1000 lbf <br />Shear 390 lbf <br />Datasheet <br />Row-to-Row Spacer <br />Row-to-Row Grounding Clip <br />Classic and Universal InvisiMount Universal InvisiMount Only <br /> Universal End Clamp <br />Row-to-row Grounding Jumper <br /> Universal Mid Clamp <br />613 W Tribella Ct - <br />10111607908/29/23
The URL can be used to link to this page
Your browser does not support the video tag.