Laserfiche WebLink
(N) (33) VSUN405-108BMH MODULES <br />WITH SOLAREDGE S440 POWER OPTIMIZERS <br />ATTACHED TO EACH MODULE <br />(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br /> GROUND SPLICE <br />BR <br />A <br />N <br />C <br />H <br /> <br /># <br />1 <br />BR <br />A <br />N <br />C <br />H <br /> <br /># <br />2 <br /> <br />BR <br />A <br />N <br />C <br />H <br /> <br /># <br />3 <br /> <br />11 MODULES IN BRANCH #1 <br />11 MODULES IN BRANCH #2 <br />11 MODULES IN BRANCH #3 <br />2 <br /> G <br />L1 <br />L2 <br />N <br /> SOLAREDGE SE10000H-US <br />[SI1-JUN22] INVERTER <br />G <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />1 M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />60A <br />150A <br />N <br />3 (E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />BACKFEED <br />BREAKER <br />(N) VISIBLE LOCKABLE <br />SQUARE D DU222RB 2 <br />POLE 60A 'KNIFE' AC <br />DISCONNECT <br />3 <br />AC <br />DISCONNECT <br />TO BE LOCATED <br />WITHIN 10' OF <br />METER <br />NEW <br />240V/200A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />SPD (N) SURGE <br />PROTECTOR <br />DEVICE <br />10' <br />SHEET <br />CONTRACTOR <br />GREEN DAY POWER <br />ADDRESS: 9745 BUSINESS <br />PARK DRIVE SACRAMENTO, <br />CA 95827 <br />LE <br />RESIDENCE <br />DESIGNER: OSM <br /> License#: 1038673 <br />711 S SHANNON ST, <br />SANTA ANA, <br /> CA 92704 <br />DATE:7/1/2023 <br />APN: 10860106 <br />E-1 <br />MAIN SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 200A <br />MAX BREAKER SIZE: <br />(200A X 1.2) - 150A = 90.0A <br />METER # SCE222013568783 <br />Inverter Ratings <br />Inverter Make/Model <br />SOLAREDGE <br />SE10000H-US <br />[SI1-JUN22] <br />INVERTER <br />Max DC Volt Rating 480V <br />Peak Output Power 10000W <br />Max Nominal Voltage 240V <br />Max AC Current 42A <br />Max OCPD Rating 60A <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW 2°C <br />ASHRAE 2% HIGH 31°C <br />PV Module Ratings @ STC <br />Module Make/Model VSUN SOLAR <br />VSUN405-108BMH <br />Max Power-Point Current (Imp)12.92A <br />Max Power-Point Voltage (Vmp)31.36V <br />Open-Circuit Voltage (Voc)37.36V <br />Short-Circuit Current (Isc)13.78A <br />Max Series Fuse (OCPD)30A <br />Nominal Maximum Power at STC <br />(Pmax)405W <br />Maximum System Voltage 1500V <br />Voc Temperature Coefficient -0.27%/°C <br />ELECTRICAL DIAGRAM <br />Conduit and Conductor Schedule <br />Tag Description Wire <br />Gauge # of Conductors Conduit Type Conduit Size <br />1 10 AWG 6 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 6(+3V,-3V)EMT 3/4" <br />2 THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />3 THWN-2 6 AWG 3 EMT 3/4" <br />3 THWN-2 - Ground 8 AWG 1 EMT 3/4" <br />PV CABLE <br />705.12(D)(2)(3)(b) CALC FOR MAIN <br />SERVICE PANEL <br />200A BUSBAR X 1.2 = 240A <br />PV BACKFEED: (10000/240)*1.25 = 52.08A <br />150A+52.08A= 202.08A < 240A <br />THEREFORE OK <br />SYSTEM SUMMARY <br />OPTIMIZER SHORT CIRCUIT <br />CURRENT <br />NO.OF MODULES PER STRING <br />ARRAY STC POWER <br />ARRAY PTC POWER <br />MAX AC CURRENT <br />MAX AC POWER <br />DERATED (CEC) AC <br />POWER <br />BRANCH #1 BRANCH #2 <br />15 <br />11 11 <br />A A <br />BRANCH #3 <br />13365W <br />42A <br />10000W <br />12027.86W <br />11 <br />A <br />12464.1W <br />15 15 711 S Shannon St - <br />2018052908/17/23