My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
711 S Shannon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Shannon St
>
711 S Shannon St
>
711 S Shannon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:34 PM
Creation date
6/1/2025 12:08:09 PM
Metadata
Fields
Template:
Plan
Permit Number
20180529
101116147
Full Address
711 S Shannon St
Document Relationships
101116147 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Shannon St\711 S Shannon St
20180529 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Shannon St\711 S Shannon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET <br />CONTRACTOR <br />GREEN DAY POWER <br />ADDRESS: 9745 BUSINESS <br />PARK DRIVE SACRAMENTO, <br />CA 95827 <br />LE <br />RESIDENCE <br />DESIGNER: OSM <br /> License#: 1038673 <br />711 S SHANNON ST, <br />SANTA ANA, <br /> CA 92704 <br />DATE:7/1/2023 <br />APN: 10860106 <br />E-2.1 <br />WARNING LABELS-2 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />AT EACH AC DISCONNECTING <br />PHOTOVOLTAIC <br />AC AMPERAGE <br />OPERATING CURRENT: <br />OPERATING VOLTAGE: <br />42.00A AC <br />240V AC <br />AT POINT OF INTERCONNECTION, MARKED <br />AT AC DISCONNECTING MEANS <br />! WARNING! <br />PHOTOVOLTAIC POWER SOURCE <br />MAIN <br />PV SOLAR ARRAY <br />JBOX <br />16.5A DC <br />380V DC <br />480V DC <br />30A DC <br />LABELING NOTES <br />1. LABELING REQUIREMENTS BASED ON THE 2022 CALIFORNIA ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA <br />STANDARD 1910.145, ANSI Z535 <br />2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. <br />4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. <br />5. PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE <br />PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)]WHERE THE INVERTERS ARE <br />REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV <br />SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS <br />SUBPANEL/ <br />LOAD CENTER <br />(IF APPLICABLE) <br />PV SOLAR BREAKER <br />OVERCURRENT DEVICE <br />AT POINT OF INTERCONNECTION <br />OVERCURRENT DEVICE <br />DISCO <br />AC <br />SERVICE <br />PANEL <br />EQUIPMENT MAY VARY <br />FOR EACH APPLICATION <br />(NOT ALL APPLICABLE) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(3), <br />CFC 2022: 1204.5.3 <br />PV METER <br />(IF APPLICABLE) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 42.0 AMPS <br />240.0 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />COMBINER PANEL/ INVERTER <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 690.13(B) <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />! <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />WARNING <br />LABEL LOCATION: <br /> PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(2)(3)(c), <br />60A <br />M <br />WARNING <br />SOLAR ELECTRIC CIRCUIT <br />BREAKER IS BACKFED <br />DO NOT RELOCATE THIS <br />711 S Shannon St - <br />2018052908/17/23
The URL can be used to link to this page
Your browser does not support the video tag.