Laserfiche WebLink
3' <br />1'-6" <br />1'-6" <br />3' 3' <br />3' <br />1'-6" <br />1'-6" <br />3' 3' <br />N <br />SCALE: 1/16" = 1'-0" <br />PV SYSTEM SITE PLAN <br />PV SYSTEM SIZE: <br />13.365 kW DC <br />CONSTRUCTION NOTES <br />Roof Azimuth: 161 ° <br />Roof Tilt: 20° <br />Roof Section 3 <br />ROOF OBSTRUCTIONS <br />SHEET <br />CONTRACTOR <br />GREEN DAY POWER <br />ADDRESS: 9745 BUSINESS <br />PARK DRIVE SACRAMENTO, <br />CA 95827 <br />LE <br />RESIDENCE <br />DESIGNER: OSM <br /> License#: 1038673 <br />711 S SHANNON ST, <br />SANTA ANA, <br /> CA 92704 <br />DATE:7/1/2023 <br />APN: 10860106 <br />PV-1 <br />Roof Azimuth: 251° <br />Roof Tilt: 20° <br />Roof Section 1 <br />SITE PLAN LAYOUT <br />1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON <br />RESIDENTIAL STRUCTURE. <br />2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE <br />WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC <br />WIND SPEED OF 95 MPH (3 SECOND GUST), WIND <br />EXPOSURE C. <br />3. THE ROOF MEMBERS ARE 2 "X 6" RAFTERS AT 24" ON <br />CENTER. CONNECTION TO STRUCTURE SHALL NOT BE <br />WITHIN 11" OF NAILING PLATES. <br />4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT <br />OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING <br />ROOF VENTS. <br />5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF <br />SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE <br />(INCLUDING CABLES UNDERNEATH MODULES AND <br />RACKING). <br />6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE <br />FOLLOWING (CRC R324.7.1, CBC 3111.2.1) <br />6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH AS <br />DOORS OR WINDOWS. <br />6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH <br />AS: TREES, WIRES, OR SIGNS. <br />7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES <br />IN COMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.1.2 <br />TOTAL PLAN VIEW AREA = 2296.6 SQFT TOTAL PV <br />AREA = 33(67.83 IN)(44.6 IN)/(144 IN^2) = 693.28 SQFT <br />(693.28 SQFT/ 2296.6 SQFT)100 = 30.19% TOTAL PV <br />AREA POPULATES 30.19% OF TOTAL PLAN VIEW <br />AREA AND IS WITHIN THE 33% REQUIREMENT. <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LI <br />NE <br />NEW SOLAR PANELS <br />LEGEND <br />INV INVERTER <br />PROPERTY LINE <br />PROPE <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />DR <br />I <br />V <br />E <br />W <br />A <br />Y <br />ACD AC DISCONNECT <br />M <br />AC <br />D <br /> <br />IN <br />V <br /> <br />Roof Azimuth: 71 ° <br />Roof Tilt: 20° <br />Roof Section 2 <br />PV INTERCONNECTION POINT. <br />LOCATION OF METER MAIN COMBO, STRING <br />INVERTER & AC DISCONNECT MOUNTED ON <br />EXTERIOR WALL OF A SINGLE FAMILY <br />RESIDENCE. <br />LOCATION OF "RAPID SHUTDOWN" <br />DISCONNECT NEC 690.12 <br />(E) SERVICE DROP <br />PROPE <br />R <br />T <br />Y <br /> LINE <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />71 <br />1 <br /> <br />S <br /> <br />S <br />H <br />A <br />N <br />N <br />O <br />N <br /> <br />S <br />T <br /> <br />M METER MAIN COMBO <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />CAL-FIRE ROOF LADDER <br />ACCESS POINT <br />Signed: 07/03/2023 <br />Structural <br />Only 711 S Shannon St - <br />2018052908/17/23