Laserfiche WebLink
MSP <br />CB <br />JB <br />REV: F <br />AHJ: CA-CITY OF SANTA ANA <br />33.774117, -117.874394 <br />APN: 00229158 <br />NAME: JEANNE THAI <br />DRAFTED BY: K.SHITOLE <br />ADDRESS: 760 W ASTER PI, SANTA <br />ANA, CA 92706 <br />PHONE: (714) 468-2021 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-75436 <br />PAPER SIZE: 17"X11"SHEET: PL-01DATE: 08/01/2023 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: K.NEEL <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA <br />92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />760 W ASTER PI, SANTA ANA, CA 92706 <br />PLACARDS <br />INSTALLED ON: DC DISCONNECT, INVERTER <br />[TO BE USED WHEN INVERTER IS UNGROUNDED] <br />! WARNING! <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS PHOTOVOLTAIC <br />SYSTEM ARE UNGROUNDED AND MAY BE <br />ENERGIZED <br />INSTALLED ON: AC DISCONNECT, POINT OF <br />INTERCONNECTION <br />APPLICABLE CODE(S): CEC 690.13 <br />! WARNING! <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALSON <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />WARNING-ELECTRIC SHOCK HAZARD <br />NO USER SERVICEABLE PARTS INSIDE <br />CONTACT AUTHORIZED SERVICE <br />PROVIDE FOR ASSISTANCE <br />INSTALLED ON: INVERTER, JUNCTION BOXES(ROOF), <br />AC DISCONNECT <br />SOLAR DISCONNECT <br />INSTALLED ON: DISCONNECT, POINT OF INTERCONNECTION <br />PER CODE: CEC690.13(B) <br />SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER EACH SOLAR MODULE <br />! WARNING <br />DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />INSTALLED ON: POINT OF INTERCONNECTION <br />APPLICABLE CODE(S): CEC 705.12(B)(3-4) AND 690.59 <br />!! <br />INSTALLED ON: POINT OF INTERCONNECTION <br />APPLICABLE CODE(S): CEC 705.12(B)(3)(2) <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVER-CURRENT DEVICE <br />INSTALLED ON: AC DISCONNECT(S), POINT OF <br />INTERCONNECTION. <br />APPLICABLE CODE(S): CEC 690.54 <br />RATED AC OPERATING CURRENT <br />AC NOMINAL OPERATING VOLTAGE <br />18.85 <br />240 <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH <br />AMPS AC <br />VAC <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN <br />1.PLACARDS SHALL MEET THE <br />REQUIREMENTS OF ARTICLES 690 AND <br />705, UNLESS OTHERWISE SPECIFIED <br />PER LOCAL AHJ REQUIREMENTS. <br />2.PLACARDS SHALL MEET THE <br />REQUIREMENTS OF SECTION 110.21(B) <br />AS REQUIRED AND SHALL COMPLY WITH <br />ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS. <br />3.PLACARDS SHALL BE PERMANENTLY <br />AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD. <br />4.PLACARDS SHALL BE OF SUFFICIENT <br />DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED AND SHALL BE <br />HANDWRITTEN. <br />5.PLACARDS SHALL NOT COVER <br />EXISTING MANUFACTURER LABELS. <br />NOTES <br />CAUTION:MULTIPLE SOURCES <br />OF POWER !! <br />LABEL LOCATION <br />SERVICE PANEL <br />PER CODE: CEC 705.10 <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br /> SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br /> SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />INSTALLED ON: WITHIN 3 FT OF SERVICE <br />DISCONNECTING MEANS. MIN 3/8" BLACK TEXT ON <br />YELLOW BACKGROUND & 3/16" BLACK TEXT ON WHITE <br />BACKGROUND. <br />APPLICABLE CODE(S): CEC 690.56(C) <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />INSTALLED ON:RAPID SHUTDOWN SWITCH <br />APPLICABLE CODE(S): CEC 690.56(C)(2) <br /> DEDICATED PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL NO LOAD SHALL BE <br />ADDED TO THIS PANEL <br />THE MAIN BREAKER IN THIS PANEL HAS <br />BEEN DERATED TO 200A <br />DO NOT INSTALL LARGER BREAKER <br />(E)PHOTOVOLTAIC ARRAY <br />ON THE ROOF <br />(E) UTILITY METER WITH <br />(E) MAIN SERVICE PANEL (EXTERIOR) <br />(N) ENPHASE IQ COMBINER 4 (INTERIOR) <br />(N)PHOTOVOLTAIC ARRAY <br />ON THE ROOF <br />(E) ENPHASE COMBINER (EXTERIOR) <br />JUNCTION BOX <br />(N) LOAD CENTER (EXTERIOR) <br />A <br />(E) AC DISCONNECT (EXTERIOR) <br />760 W Aster Pl - <br />2018031708/09/23