My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
760 W Aster Pl - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Aster Pl
>
760 W Aster Pl
>
760 W Aster Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:08:39 PM
Creation date
6/1/2025 12:08:10 PM
Metadata
Fields
Template:
Plan
Permit Number
20180317
101115868
Full Address
760 W Aster Pl
Document Relationships
20180317 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Aster Pl\760 W Aster Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: C <br />AHJ: CA-CITY OF SANTA ANA <br />33.774117, -117.874394 <br />APN: 00229158 <br />NAME: JEANNE THAI <br />DRAFTED BY: K.SHITOLE <br />ADDRESS: 760 W ASTER PI, SANTA <br />ANA, CA 92706 <br />PHONE: (714) 468-2021 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-75436 <br />PAPER SIZE: 17"X11"SHEET: CS-01DATE: 05/09/2023 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: K.NEEL <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA <br />92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />AERIAL MAP VICINITY MAP <br />HOUSE VIEW <br />TOTAL ARRAY AREA = 274.57 sq.ft <br />TOTAL ROOF AREA = 3317 sq.ft <br />% ARRAY AREA IN ROOF = 8.28 % <br />ROOF AREA CALCULATION <br />PROJECT WINDSPEED DETERMINED USING THE <br />ASCE 7 STANDARD UNLESS DIRECTED OTHERWISE <br />BY LOCAL JURISDICTION AMENDMENTS <br />COVER SHEET <br />DESIGN CRITERIA <br />BASIC WIND SPEED = 95 MPH @ 3-SEC GUST <br />GROUND SNOW LOAD = 0 PSF <br />JEANNE THAI - 5.265kW DC, 4.537kW AC, 4.745kW CEC AC RATING <br />APPLICABLE CODES <br />·ELECTRIC CODE:CEC 2022 <br />·FIRE CODE:CFC 2022 <br />·BUILDING CODE:CBC 2022 <br />·RESIDENTIAL CODE:CRC 2022 <br />SYSTEM SIZE: <br />MODULES: <br />INVERTER: <br />5265W DC, 4537W AC, 4745W CEC AC <br />RATING <br />SCOPE OF WORK <br />(13)HANWHA Q CELLS Q.PEAK DUO BLK <br />ML-G10+ 405W <br />(13)ENPHASE IQ8A-72-2-US (240V)(SI-1) <br />BRANCH DETAILS: <br />1X7, 1X6 ENPHASE BRANCHES <br />SHEET CATALOG <br />SHEET REVISION DESCRIPTION <br />CS-01 C COVER SHEET <br />CS-02 C GENERAL NOTES <br />E-01 C SITE PLAN <br />S-01 C MOUNTING DETAILS <br />S-02 C STRUCTURAL DETAILS <br />E-02 C SINGLE LINE DIAGRAM <br />E-03 C ELECTRICAL CALCULATIONS <br />E-04 C ELEVATION VIEW <br />E-05 C ELECTRICAL LOAD <br />CALCULATION <br />PL-01 C PLACARDS <br />SS C SPEC SHEET(S) <br />1. MODULES ARE LISTED UNDER UL 61730 AND CONFORM TO THE STANDARDS. <br />2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. <br />3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE <br />CONDITION MIGHT VARY. <br />4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH <br />CEC 110.26. <br />5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. <br />6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. <br />7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION <br />AND/OR THE UTILITY. <br />9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION <br />WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. <br />10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING <br />GENERAL NOTES <br />RISK CATEGORY- ll <br />DERATING DETAILS: <br />REPLACE EXISTING MAIN BREAKER <br />WITH NEW 200A MAIN BREAKER <br />The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and <br />state codes and regulations regarding construction. <br />The approval of the plans does not constitute any <br />certification of the accuracy, completeness, or <br />building permit status of the existing buildings and <br />structures as shown. <br />Bldg# 101115868 <br />Elec# 20180317 MS <br />Issued 08/08/23 <br />760 W Aster Pl - <br />2018031708/09/23
The URL can be used to link to this page
Your browser does not support the video tag.