Laserfiche WebLink
City of Santa Ana <br />Building and Safety Department <br />- <br />Santa Ana, CA <br />Subject:Flush-mount PV Installation on New Residences <br />Project: <br />Plan:5A Lot #19 # of Mod 9 <br />860 South Harbor Blvd No. of Stories:3 <br />Santa Ana, CA <br />V&A Project No. 15-3457 <br />The purpose of this letter is to provide a review of the existing single family residential <br />development for the attachment and support of the proposed photovoltaic arrays as outlined in <br />the drawings prepared by Sunnova for City Ventures. The limitation to our review is to <br />the overall support and attachment of the photovoltaic array to the roof system designed by <br />others. The gravity and lateral inpact of the proposed solar system has been accounted for in <br />the original design for the project by the engineer of record for the development <br />The project is to be constructed by City Ventures and has been designed by another licensed <br />engineer per the requirements of the latest edition of the 2022 CBC as amended by the local jurisdiction. <br />Our design includes the assumption that the structure has been designed by a California Licensed <br />engineer and that the structure has been constructed in accordance with that design. <br />The proposed roof structures have been designed for a top chord design dead load of <br />10 psf, which includes 2.5 psf PV allowance. <br />The project has been designed for a wind exposure C, with an basic wind speed of 100 MPH. <br />The roof is to be constructed of composition shingles. <br />The photovoltaic array will mount flush to the roof planes with a maximum of 8" space between <br />the bottom of the panels and the finish roofing. The proposed photovoltaic array consists of <br />9 modules on each roof. Roof pitches may vary between 3:12 & 5:12. <br />Panels shall be setback a minimum of 36" from ridge lines and 19" from valleys for all orientations. <br />The photovoltaic array rails shall run perpendicular to the roof slope. The photovoltaic array <br />mounts shall be Unirac, Solar Mount, L-foot or equivalent and shall be installed at a spacing <br />not more than 48” o.c. Each mount shall connected to the roof truss top chord with a minimum <br />of (1) 5/16” diameter stainless steel lag screw with a minimum of 2-1/2” penetration into the top <br />chord of the truss. Vertically adjacent mounts shall not bear on the same roof trusses, but <br />should be staggered over every other truss wherever possible. Mounts should be within 12” of <br />the ends of all rails. <br />V I N C I & A S S O C I A T E S <br />Structural Engineers <br />October 11, 2023 <br />Santa Ana 7 Multi Family Residential Development <br />175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 <br />805.496.2100 • VinciSE.com <br />860 S Harbor Blvd <br />1/2/2024