Laserfiche WebLink
Sheet: <br />Date: <br />02.23.2023 <br />Residential Roof <br />Mounted <br />Photovoltaic System <br />System Size (DC): <br />Modules: <br />Inverter: <br />Tom Van Aken <br />Project Name and Address: <br />417 S Clara St Unit #2, <br />Santa Ana, CA 92703, <br />Title: <br />x Hyundai 405W HiS-S405YH(BK)6 <br />Enphase IQ7Plus-72-2-US <br />AWS Electrical & Solar Inc <br />11750 Roscoe Blvd, Suite 7, Sun <br />Valley, CA 91352, USA <br />Phone: (818) 484-3264 <br />AWS-Solar.com <br />License number C10#901196 <br />System Size (AC): <br />x x = 6 381.1 0.97 2.22 KW <br />x =6 405 2.43 KW <br />x6 <br />PV-5 <br />CODE REQUIRED <br />SIGNAGE <br />PV ARRAY J BOX <br />INVERTER <br />*if applicable <br />INTEGRATED <br />DC DISCONNECT <br />PV SUB-PANEL <br />*if applicable *if applicable <br />SUB-PANEL <br />AC DISCONNECT <br />*if applicable <br />MAIN SERVICE <br />PANEL <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />1 WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />On Ext. and Int. Conduit Every 10 Feet <br />and within 1' of turns and within 1' above/or <br />below penetrations and all Junction Boxes. <br />Reflective. NEC 690.31(G) <br />1 1 1 1 1 <br />CAUTION: PHOTOVOLTAIC J-BOX2 <br />2 <br />3 WARNING <br />ELECTRIC SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />4 WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH THE TERMINALS. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION. <br />3 4 <br />PV SUB-PANEL ONLY5 <br />To be located on SUB-panel <br />only when SUB-panel is <br />dedicated for PV only <br />6 AC DISCONNECT <br />RATED AC OUTPUT CURRENT- A MAX <br />NOMINAL AC OPERATING VOLTAGE: 240 Vac <br />AC PHOTOVOLTAIC POWER SOURCE <br />Sticker located on IQ combiner box <br />THIS PANEL FED BY <br />MULTIPLE SOURCES <br />(UTILITY & SOLAR) <br />7 <br />SOLAR8 <br />Sticker located <br />inside panel next <br />to solar breaker <br />9 WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />Sticker located inside panel below PV breaker <br />10 PV LOAD CENTER SIZED FOR PV <br />BREAKERS ONLY OR RENDERED UNABLE <br />TO ACCEPT ANY ADDITIONAL LOADS. <br />Sticker located on the PV SUB panel. <br />5 6 7 <br />8 9 10 <br /> 6 7 <br />8 9 10 <br /> 6 <br />PV METER <br />*if applicable <br /> M <br /> M <br />11 CAUTION MULTIPLE <br />SOURCES OF POWER <br />705.12 (D)(3) <br />12 RAPID SHUT DOWN SWITCH <br />FOR SOLAR PV SYSTEM <br /> 11 <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH ON THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br />13 <br />6 7 8 <br />9 11 12 <br />13 14 <br />Note: Materials used for all marking shall be <br />reflective, weather resistant and suitable for the <br />environment. All letters shall be a minimum height <br />of 3/8", capitalized and white on a red background. <br />S Clara St <br />SERVICE POINT & <br />UTILITY METERING <br />AC DISCONNECT <br />Solar Modules <br /> 7.3 <br />417 S Clara St #2 <br />04/17/23