© 2020 IronRidge, Inc. FlashVue Certification Letter - 1 <br />28357 Industrial Blvd <br />Hayward, CA 94545 <br />1-800-227-9523 <br />www.IronRidge.comAttn: Corey Geiger, COO, IronRidge Inc. <br />Date: September 18th, 2020 <br />Re: Structural Certification for the IronRidge FlashVue <br />This letter certifies the structural capacity of IronRidge FlashVue for use as a roof attachment for flush mounted PV solar <br />systems. The FlashVue assembly consists of an aluminum bracket cap (GripCap or GripCap Plus) and an 8” x 12” <br />aluminum flashing. FlashVue is fastened to an underlying roof rafter using a 5/16” x 4.25” lag bolt. The full assembly <br />details are shown in Exhibit EX-0019. <br />The referenced uplift, and lateral capacities of FlashVue are based on mechanical load tests conducted along the three <br />respective load directions shown in Figure 1, using a Universal Instron Test Unit in accordance with ASTM D1761-20 <br />“Standard Test Methods for Mechanical Fasteners in Wood and Wood-Based Materials”. For each load test, a FlashVue <br />assembly using GripCap or GripCap Plus was installed on a sample roof deck composed of 15/32” OSB Board over 2x4 <br />rafters. The moisture content and the specific gravity of the rafters were measured per ASTM D2395-17 “Standard Test <br />Methods for Density and Specific Gravity (Relative Gravity) of Wood and Wood-Based Materials”. The recorded moisture <br />content of the rafters among all sample roof decks is between 10% and 15%. For each load direction, the tests provided <br />different capacity results for Flashvue assemblies using GripCap or GripCap Plus. The tabulated results reported in this <br />letter are the lesser of the allowable capacities for GripCap or GripCap Plus and therefore are applicable to Flashvue <br />using either bracket cap. <br />The critical failure mode along the uplift direction was observed on the Flashvue using GripCap Plus as the pullout of the <br />5/16” lag bolt from the rafter. The average peak loads recorded at the ultimate failure point is 3483 lbs. on rafters with a <br />measured specific gravity of 0.50. A safety factor of 3 was applied which results in an allowable uplift capacity of 1161 lbs. <br />Along the lateral direction (parallel to rafter), the controlling failure mode was observed in the tests using GripCap Plus as <br />the bending yielding of the 5/16” lag bolt. The average peak load recorded at the ultimate failure point is 1060 lbs. A safety <br />factor of 3 was applied which results in an allowable capacity of 353 lbs. in the lateral direction along the roof slope. <br />The dominating failure mode observed for the lateral direction (perpendicular to rafter) was observed in the tests for the <br />assembly using GripCap as the compressive rupture of the OSB board adjacent to the rafter. The average peak load <br />recorded at the ultimate failure point is 772 lbs. A safety factor of 2.54 was applied according to National Design <br />Specification for Wood Construction (NDS-2018) which results in an allowable capacity along the cross slope lateral <br />direction of 304 lbs. <br />Figure 1: FlashVue Assembly and Applied Loading Directions (using GripCap or GripCap Plus). <br />417 S Clara St #2 <br />04/17/23