Laserfiche WebLink
PV-1REV: A 11/09/2022 <br />IBARRA, LORENA <br />517 S TOWNSEND STREET <br />SANTA ANA, CA 92703 <br />APN # 01006205 TEL #: (714) 955-8089 <br />CLIENT: <br />COVER SHEET <br />CSLB # 619149 CLASS: B, C-10 <br />NAME: GARY GIETZ, JACK MCCLARY <br />SIGNED: 11/09/2022 PHONE 310.904.6139 <br />ENERGY SERVICE PARTNERS <br />970 W 190TH ST, STE 302 <br />TORRANCE, CA 90502 <br />CONTRACTOR: <br />VICINITY MAPVICINITY MAP AERIAL MAP <br />NOTES <br />SCOPE OF WORK <br />INSTALLATION OF GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM <br />12 EMMVEE 440 W E440H CM120-B SOLAR MODULES <br />1 SOLAREDGE TECHNOLOGIES 3800 W SE3800H-US (240V) HD WAVE INVERTER <br />12 SOLAREDGE TECHNOLOGIES 440 W S440 OPTIMIZER <br />SYSTEM NAMEPLATE POWER 5.280 KW DC <br />SYSTEM CEC POWER 4.854 KW CEC-AC <br />CONSTRUCTION TYPE V-B <br />OCCUPANCY TYPE R-3 <br />UPGRADE TO NEW 200A MAIN BUSS/ W NEW 200A MAIN BREAKER <br />SHEET INDEX <br /> 1 COVER SHEET <br />2 SIGNAGE <br />3 SITE/ROOF PLAN <br />4 STRUCTURAL <br />5 ELECTRICAL <br />6 ELECTRICAL <br />CALCS <br />· ALL MATERIALS, EQUIPMENT, INSTALLATION AND <br />WORK SHALL COMPLY WITH THE FOLLOWING <br />APPLICABLE CODES: <br />·2019 CBC / 2018 IBC <br />·2019 CRC / 2018 IRC <br />·2019 CEC / 2017 NEC <br />·2019 CMC / 2018 UMC <br />·2019 CPC / 2018 UPC <br />·2019 CFC / 2018 IFC <br />·2019 CA ENERGY CODE <br />·2019 GREEN CODE <br />1. ALL WORK TO COMPLY WITH CEC ARTICLE 690 <br />2. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION <br />OF PV SYSTEM <br />3. REMOVAL OF A UTILITY-INTERACTIVE INVERTER <br />OR OTHER EQUIPMENT SHALL NOT DISCONNECT <br />THE BUILDING CONNECTION BETWEEN THE <br />GROUNDING ELECTRODE CONDUCTOR AND THE <br />PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED <br />CONDUCTOR <br />4. ALL PV SYSTEM COMPONENTS SHALL BE LISTED <br />BY A RECOGNIZED TESTING AGENCY <br />5. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM <br />CONTINUOUS CURRENT OUTPUT AT 25° C; WIRE <br />SHALL BE WET RATED AT 90°C <br />6. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS <br />ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. <br />7. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES <br />SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN <br />WET LOCATIONS (CEC 314.15) <br />8. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL <br />BE BONDED AND ELECTRICALLY CONTINUOUS <br />(CEC 250.90, 250.96) <br />9. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC <br />SOURCE AND OUTPUT CIRCUITS SHALL BE <br />PROVIDED WITH A GROUND-FAULT PROTECTION <br />DEVICE OR SYSTEM THAT DETECTS A GROUND <br />FAULT, INDICATES THAT FAULT HAS OCCURED, <br />AND AUTOMATICALLY DISCONNECTS ALL <br />CONDUCTORS OR CAUSES THE INVERTER TO <br />AUTOMATICALLY CEASE SUPPLYING POWER TO <br />OUTPUT CIRCUITS <br />10. ANY REQUIRED GROUNDING ELECTRODE <br />CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR <br />SPLICES OR JOINTS AT BUSBARS WITHIN LISTED <br />EQUIPMENT (CEC 250.64C) <br />11. ALL PV MODULES AND ASSOCIATED EQUIPMENT <br />SHALL BE PROTECTED FROM ANY PHYSICAL <br />DAMAGE <br />12. ALL FIELD-INSTALLED JUNCTION, PULL, AND <br />OUTLET BOXES SHALL BE LOCATED IN A READILY <br />ACCESSIBLE LOCATION DIRECTLY OR BY <br />DISPLACEMENT OF A MODULE SECURED BY <br />REMOVABLE FASTENERS <br />13. FOR GROUNDED SYSTEMS, THE INVERTER IS <br />EQUIPPED WITH GROUND FAULT PROTECTION AND <br />A GFI FUSE PORT FOR GROUND FAULT INDICATION <br />14. WHEN BACKFED BREAKER IS THE METHOD OF <br />UTILITY INTERCONNECTION, THE BREAKERS SHALL <br />NOT READ "LINE AND LOAD" <br />15. THE INSTALLED SOLAR SYSTEM HAS A <br />DISTRIBUTED WEIGHT OF LESS THAN 4 PSF <br />16. THE CONCENTRATED LOAD FOR EACH VERTICAL <br />SUPPORT IS LESS THAN 45 LBS <br />17. AC DISCONNECT IS A "KNIFE BLADE" TYPE <br />DISCONNECT <br />18. THE WORKING CLEARANCES AROUND THE <br />EXISTING ELECTRICAL EQUIPMENT AS WELL AS <br />THE NEW ELECTRICAL EQUIPMENT WILL BE <br />MAINTAINED IN ACCORDANCE WITH CEC 110.26 <br />19. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS <br />UL 1741 COMPLIANT <br />20. SMOKE ALARMS AND CARBON MONOXIDE ALARMS <br />ARE REQUIRED TO BE RETROFITTED ONTO THE <br />EXISTING DWELLING AS PER THE 2019 CRC. <br />THESE SMOKE ALARMS ARE REQUIRED TO BE IN <br />ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND <br />AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />CARBON MONOXIDE ALARMS ARE REQUIRED TO <br />BE RETROFITTED OUTSIDE EACH BEDROOM AND <br />AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />THESE ALARMS MAY BE SOLELY BATTERY <br />OPERATED IF THE PHOTOVOLTAIC PROJECT DOES <br />NOT INVOLVE THE REMOVAL OF INTERIOR WALL <br />AND CEILING FINISHES INSIDE THE HOME; <br />OTHERWISE, THE ALARMS MUST BE HARD WIRED <br />AND INTERCONNECTED. (CRC R314, R315) <br />21. SMOKE AND CARBON MONOXIDE ALARMS ARE <br />REQUIRED PER CRC SECTIONS R314 AND 315 TO <br />BE VERIFIED AND INSPECTED BY THE INSPECTOR <br />IN THE FIELD. <br />22. WHEN APPLYING THE 120% RULE OF CEC 705.12(B) <br />, THE SOLAR BREAKER TO BE POSITIONED AT THE <br />OPPOSITE END OF THE BUS FROM THE MAIN <br />BREAKER PER 705.12(B) <br />23. PLUMBING AND MECHANICAL VENTS THROUGH <br />THE ROOF SHALL NOT BE COVERED BY SOLAR <br />MODULES - NO BUILDING, PLUMBING, OR <br />MECHANICAL VENTS TO BE COVERED OR <br />OBSTRUCTED <br />This item has been digitally signed <br />and sealed on 11/18/2022 <br />STRUCTURAL ONLY <br />BLDG 101113386 ISS. 01/12/2023 <br />ELEC 20178359 ISS. 01/12/2023 <br /> <br />The scope of the plans is for the <br />installation of the solar photovoltaic <br />system only and the approval is <br />subject to compliance with all <br />applicable city and state codes and <br />regulations regarding construction. <br />The approval of the plans does not <br />constitute any certification of the <br />accuracy, completeness, or building <br />permit status of the existing <br />buildings and structures as shown. <br />517 S Townsend St <br />01/13/23