Laserfiche WebLink
M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />20A <br />100A <br />N <br />3 (E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />BACKFEED <br />BREAKER <br />(N) VISIBLE <br />LOCKABLE <br />2 POLE 30A <br />'KNIFE' AC <br />DISCONNECT <br />3 <br />EXISTING <br />240V/100A <br />METER MAIN COMBO <br />SINGLE PHASE <br />12 <br />PV CIRCUIT 1: 12 MODULES/PARALLEL <br />2 <br />RO <br />O <br />F <br /> <br />TO <br />P <br />GR <br />O <br />UN <br />D <br /> <br />LEV <br />EL <br /> <br />- <br />HO <br />U <br />S <br />E <br /> <br />EX <br />T <br />E <br />R <br />I <br />OR <br />1 2 1 <br />(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />20A <br />N <br />15A <br />(N) 12 HANWHA Q.CELLS Q.PEAK DUO BLK-G10+ 365W <br />MODULES <br /> WITH AN ENPHASE IQ7-60-2-US MICRO-INVERTER <br />ATTACHED TO THE BACK OF EVERY MODULE. <br />(N) 125A/240V AC <br />COMBINER BOX WITH <br />ENPHASE IQ ENVOY <br />COMM. GATEWAY <br />EN <br />P <br />H <br />A <br />S <br />E <br /> <br />I <br />Q <br />EN <br />V <br />O <br />Y <br />CO <br />M <br />M <br />U <br />N <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />GA <br />T <br />E <br />W <br />A <br />Y <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL SHEET <br />CONTRACTOR <br />ILUM SOLAR <br />BYSTEDT <br />RESIDENCE <br />License#:1009260, C-46 <br />ADDRESS: <br />4135 NORTHGATE BLVD <br />SUITE 9, SACRAMENTO, <br />CA 95834, USA <br />DESIGNER: OPK <br />514 E BUFFALO AVE, <br /> SANTA ANA, <br /> CA 92706 <br /> APN:00313126 <br /> DATE:9/23/2022 <br />E-1 <br />Conduit and Conductor Schedule <br />Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size <br />1 Enphase Q cable - THWN-2 12 AWG 1 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 12 AWG 2 EMT 3/4" <br />2 THWN-2 - Ground 10 AWG 1 EMT 3/4" <br />3 THWN-2 10 AWG 3 EMT 3/4" <br />3 THWN-2 - Ground 10 AWG 1 EMT 3/4" <br />MAIN SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 100A <br />MAX BREAKER SIZE: <br />(100A X 1.2) - 100A = 20.0A <br />Inverter Ratings <br />Inverter Make/Model ENPHASE <br />IQ7-60-2-US <br />Max DC Volt Rating 48V <br />Max con output Power 240W <br />Max Nominal Voltage 240V <br />Max AC Current 1A <br />Max OCPD Rating 20A <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW 1°C <br />ASHRAE 2% HIGH 30°C <br />PV Module Ratings @ STC <br />Module Make/Model <br />HANWHA Q.CELLS <br />Q.PEAK DUO <br />BLK-G10+ 365W <br />MODULE <br />Max Power-Point Current (Imp)10.56A <br />Max Power-Point Voltage (Vmp)34.58V <br />Open-Circuit Voltage (Voc)41.21V <br />Short-Circuit Current (Isc)11.07A <br />Max Series Fuse (OCPD)20A <br />Nominal Maximum Power at STC (Pmax)365W <br />Maximum System Voltage 1000V <br />Voc Temperature Coefficient -0.27%/K <br />SYSTEM SUMMARY <br />BRANCH #1 <br />INVERTERS PER BRANCH 12 <br />MAX AC CURRENT 12.00A <br />MAX AC OUTPUT POWER 2880W <br />ARRAY STC POWER 4380W <br />MAX AC CURRENT 12.00A <br />MAX AC POWER 2880W <br />514 E Buffalo Ave <br />11/04/22