MOUNTING DETAILS <br />S-1.0 <br />CUSTOMER INFORMATION <br />NAME&ADDRESS: <br />34° 7'40.41"N 117°55'50.30"W <br />APN:100-412-12 <br />AHJ:CA-CITY OF SANTA ANA <br />SYSTEM INFORMATION <br />DESIGNER/CHECKED BY: <br />RK/PI <br />PROJECT NUMBER:SSNC-008834 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />MARIA CAMACHO <br />4618 W HOLLYLINE AVE, SANTA ANA, CA 92703. <br />ENGINEER OF RECORD <br />DATE:5/25/2023 REV:B <br />DC SYSTEM SIZE: 5680W <br />AC SYSTEM SIZE: 4640W <br />CEC AC SYSTEM SIZE: 5146W <br />MODULES: <br />(16)LONGI LR4-60HPB-355M <br />INVERTER: <br />(16)ENPHASE IQ8PLUS-72-2-US(240V,1PH) <br />BRANCH DETAILS: <br />2 BRANCH OF 8 MICRO INVERTERS (8 MODULES) <br />CONTRACTOR INFORMATION <br />SOLARSUN CO <br />18662 OAK PARK DR, RIVERSIDE, CA 92504. <br />TEL:928-707-2386 <br />LIC:#B C46@1093510 <br />PV-3.0 <br />B MOUNTING DETAILS <br />SCALE: 3/32" = 1'-0" <br />UPLIFT CALCULATIONS <br />UPLIFT 9412.4 LBS <br />PULL OUT STRENGTH 20910 LBS <br />POINT LOADING 20 LBS <br />MODULES DATA <br />LONGI LR4-60HPB-355M <br />MODULE DIMS 69.09"x40.87"x1.38" <br />LAG SCREWS 5/16"x3":2.5"MIN EMBEDMENT <br />AERIAL VIEW <br />SITE INFORMATION <br />SR.NO AZIMUTH PITCH NO. OF <br />MODULES <br />ARRAY AREA <br />(SQ. FT.)ROOF TYPE ATTACHMENT ROOF <br />EXPOSURE FRAME TYPE FRAME <br />SIZE <br />FRAME <br />SPACING <br />MAX RAIL <br />SPAN <br />OVER <br />HANG <br />MP-01 78° 18° 6 117.7 W-TILE <br />CONCRETE TILE HOOK ATTIC RAFTERS 2 X 6 1'-4"4'-0" 2'-0" <br />MP-02 168° 18° 7 137.3 W-TILE <br />CONCRETE TILE HOOK ATTIC RAFTERS 2 X 6 1'-4"4'-0" 2'-0" <br />MP-03 258° 18° 3 58.8 W-TILE <br />CONCRETE TILE HOOK ATTIC RAFTERS 2 X 6 1'-4"4'-0" 2'-0" <br />MINIMUM FIRE ACCESS PATHWAYS PER CFC 2022 <br />RIDGE TO ARRAY: 1'-6" <br />EAVE TO ARRAY : 3'-0" <br />HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" <br />EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" <br />NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED <br />SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. <br />FIRE SETBACK <br />DEAD LOAD CALCULATIONS <br />BOM QUANTITY LBS/UNIT TOTAL <br />WEIGHT (LBS) <br />MODULES 16 42.99 687.84 <br />MID-CLAMP 24 0.050 1.20 <br />END-CLAMP 16 0.050 0.80 <br />RAIL LENGTH 112 0.680 76.16 <br />SPLICE BAR 2 0.360 0.72 <br />TILE HOOK 34 1.95 66.30 <br />MICRO-INVERTER 16 2.38 38.08 <br />TOTAL WEIGHT OF THE SYSTEM (LBS)871.10 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)313.75 <br />WEIGHT PER SQ. FT.(LBS)2.78 <br />WEIGHT PER PENETRATION (LBS)25.62 <br />1'-6" <br />3' <br />ARRAY MP-01 <br />ALUMINIUM RAILS <br />2 X 6 RAFTERS@ 1'-4" SPACING <br />ARRAY MP-02 <br />ARRAY MP-03 <br />4' <br />B <br />Only <br />Structural <br />4618 W Hollyline <br />Ave06/02/23