Laserfiche WebLink
278" <br />2.5 <br />" <br />MIN <br />MS <br />P <br />D <br />IN <br />V <br />SP <br />JB <br />3' <br />1 <br />2 <br />3' <br />PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />PEREA <br />"ADU" <br />5.200 DC KW <br />4.781KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />5024 1/2 <br />W 6TH ST <br />SANTA ANA, CA <br />92703 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP148126 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN11-16-22 <br />DESIGN BY: <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Smart Solar Energy <br />RD <br />A2 <br />MOUNTING <br />PLAN <br />(N) 13 - Q.PEAK DUO BLK ML-G10+ 400 <br />HANWHA Q CELL MODULES WITH <br />P401 SOLAREDGE OPTIMIZERS <br />1 STRING OF 13 MODULES <br />MOUNTING PLAN <br />SCALE: 3/32" = 1' <br />SOLAR PANEL DEAD WEIGHT CALCULATION <br />MODULE HANWHA Q CELLS <br />WIDTH (IN) LENGTH (IN) AREA (SQFT) WEIGHT (LBS) QTY <br />TOTAL <br />MODULE <br />AREA <br />TOTAL <br />MODULE <br />WEIGHT <br />41.1 74.00 21.12 48.50 13 274.57 630.50 <br />RACKING IRONRIDGE <br />RACKING <br />WEIGHT <br />LBS/LNFT <br />MOUNTING <br />SYSTEM <br />WEIGHT <br />TOTAL <br />SYSTEM <br />WEIGHT <br />TOTAL <br />ATTACHMENT <br />POINTS <br />POINT <br />LOAD <br />CALCS <br />DISTRIBUTED LOAD <br />CALCULATION <br />.75 78.81 709.31 34 20.86 2.58 PSF <br />NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 <br />ROOF COVERAGE <br />TOTAL <br />MODULE <br />AREA <br />ROOF FACE <br />AREA (SQFT) <br />ROOF <br />COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE <br />274.57 1362 20.16 20.16 </= 33% = OK <br />ROOF INFORMATION <br />ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS <br />RAFTERS AND/OR TRUSS RAFTER SPACING (IN)ATTACHMENT <br />SPACING <br />2 X 4 24" OC 48" OC <br />MODULE <br />SIDE VIEW <br />EVEREST <br />CROSSRAIL 44-X <br />EVEREST SPLICE <br />FOOT X <br />NOTE: <br />MODULES WILL BE INSTALLED <br />FLUSHED TO EXISTING ROOF SLOPE <br />END CLAMP <br />ASSEMBLY <br />EVEREST K2 SOLAR <br />SEAL BUTYL PAD <br />ROOF ATTACHMENT DETAIL <br />COMP SHINGLE <br />SCALE: 2" = 1'-0" <br />(N) 3/4" EMT CONDUIT <br />RUN ABOVE ROOF OR UNDER EAVES <br />WHERE POSSIBLE <br />WIRING/CONDUIT RACEWAY <br /> WILL BE 7/8'' MINIMUM ABOVE THE <br />ROOFTOP PER CEC 310.15(B)(3)(C) <br />34 TOTAL ATTACHMENTS <br />@ 4FT ON CENTER <br />M5 X 60 LAG SCREWS <br />5/16" Ø <br />2 LAGS PER ATTACHMENT <br />2.5" MIN EMBEDMENT <br />35 <br />8 <br />° <br /> <br />A <br />Z <br />I <br />M <br />U <br />TH <br />21 <br />. <br />9 <br />° <br /> <br />S <br />L <br />O <br />P <br />E <br />FIRE ACCESS POINT <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />LEGEND <br />(E) EXISTING <br />(N) NEW <br />(P) PROPOSED <br />CONDUIT RUN <br />VIF VERIFY IN FIELD <br />JUNCTION BOX <br />MAIN SERVICE PANEL <br />AC COMBINER <br />INVERTER <br />AC DISCONNECT <br />SUBPANEL <br />SOLAR METER <br />FIRE ACCESS POINTS <br />FIRE PATHWAY/SETBACKS <br />JB <br />MSP <br />D <br />SP <br />INV <br />AC <br />M <br />x <br />3F <br />T <br /> <br />F <br />I <br />R <br />E <br />PA <br />T <br />H <br />W <br />A <br />Y <br />(N) SE5000H-US (240V) <br />SETAPP SOLAREDGE HD INVERTER <br />(E) 125A MAIN DUAL METER PANEL <br />SCE METER#: 222014-336663 <br />(N) 30A AC DISCONNECT <br />(E) 125A SUBPANEL <br />"POI" <br />FIRE ACCESS POINT <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />3F <br />T <br /> <br />F <br />I <br />R <br />E <br />PA <br />T <br />H <br />W <br />A <br />Y <br />18" FIRE SETBACK 18" FIRE SETBACK <br />17 <br />1 <br />° <br /> <br />A <br />Z <br />I <br />M <br />U <br />T <br />H <br />21 <br />.6 <br />° <br /> <br />S <br />L <br />O <br />P <br />E <br />(E) 1-STORY <br />5024 W 6TH ST <br />(E) 1-STORY <br />5024-1/2 W 6TH <br />ST <br />(E) GARAGE <br />18" FIRE SETBACK <br />5024 1%2 W 6th St <br />01/19/23