Laserfiche WebLink
Backup Gateway 2 <br />POWERWALL <br />380 mm <br />(15 in) <br />127 mm <br />(5 in) <br />584 mm <br />(23 in) <br />Backup Gateway 2 for Tesla Powerwall provides energy management <br />and monitoring for solar self-consumption, time-based control, and <br />backup operation. <br />When the Powerwall system is in Backup mode, Backup Gateway 2 <br />controls connection to the grid, automatically detecting outages and <br />providing seamless transition to backup power. <br />Communicating directly with Powerwall, Backup Gateway 2 allows you <br />to monitor energy use and manage backup energy reserves from any <br />mobile device with the Tesla app. <br />ENVIRONMENTAL SPECIFICATIONS <br />Operating Temperature –20°C to 50°C (–4°F to 122°F) <br />Operating Humidity (RH)Up to 100%, condensing <br />Maximum Elevation 3000 m (9843 ft) <br />Environment Indoor and outdoor rated <br />Ingress Rating IP55 <br />MECHANICAL SPECIFICATIONS <br />Dimensions 584 mm x 380 mm x 127 mm <br />(23 in x 15 in x 5 in) <br />Weight 11.4 kg (25.1 lb) <br />Breaker space (DIN rail)Main breaker: 1-, 2- or 3-pole <br />Generation/Load breakers: 6 spaces <br />Mounting options Wall mount <br />PERFORMANCE SPECIFICATIONS <br />AC Voltage (Nominal)240 V (Line-to-Neutral) <br />440 V (Line-to-Line) <br />Feed-In Type Single Phase, Three Phase <br />Grid Frequency 50/60 Hz <br />Nominal Current 100 A per phase (Single Phase) <br />80 A per phase (Three Phase) <br />Maximum Input Short Circuit Current 1 6 kA1 <br />Overvoltage Category Category III <br />AC Meter Revenue accurate (+/– 0.2 %) <br />Connectivity Ethernet, Wi-Fi, Cellular (LTE/4G)2 <br />User Interface Tesla App or Local Network Monitoring <br />Operating Modes Support for solar self-consumption, <br />time-based control, and backup <br />Backup Operation Backup of selected single phase; <br />Automatic disconnect of all phases <br />Modularity Supports up to 10 AC-coupled <br />Powerwalls <br />Warranty 10 years <br />IEC-62109-1, IEC 62053-22, IEC 61439-1, <br />IEC 61439-3 <br />EMC and Radio Equipment EMC Directive 2014/30/EU, <br />Radio Equipment Directive 2014/53/EU, <br />IEC 61000-6-1, IEC 61000-6-3, <br />EN 55024, EN 300 328, EN 300 440, <br />EN 301 489-1, EN 301 489-17, <br />EN 301 489-52, EN 301 511, <br />EN 301 893, EN 301 908-1 <br />Environmental RoHS Directive 2011/65/EU, <br />WEEE Directive 2012/19/EU, <br />Battery Directive 2006/66/EC <br />REACH Regulation EC 1907/2006 <br />Seismic AC156, IEEE 693-2005 (high) <br />1 16 kA rating when installed with DIN-mount fuse; 10 kA rating without fuse. <br />2Cellular connectivity subject to network operator service coverage and signal strength <br />(2G/3G supported where LTE/4G unavailable). <br />COMPLIANCE INFORMATION <br />ROW-UK 2019-02-21 TESLA.COM/ENERGY <br />Safety <br />825 E Clemensen <br />Ave04/26/23