Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-6 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />CONTRACTOR <br />JO <br />E <br />L <br /> <br />D <br />U <br />E <br />N <br />A <br />S <br />72 <br />9 <br /> <br />W <br />E <br />S <br />T <br /> <br />C <br />E <br />N <br />T <br />R <br />A <br />L <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />, <br /> <br />U <br />S <br />A <br />NAME: POWER4WARD <br />ADDRESS: 37107 STRATFORD ST, INDIO, <br />CA 92203, USA <br />PHONE: 442-306-0930 <br />CONTRACTORLICENSE #: 1032163 <br />ELECTRICAL LICENSE#: 1032163 <br />EMAIL#: Carlosm@power4ward.com <br />APN: 14015221 <br />EMAIL: - <br />PHONE: - <br />PLACARDS <br /> <br />NOTES AND SPECIFICATIONS: <br />x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC <br />2019 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE <br />REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. <br />x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING <br />EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR <br />WIRING METHOD AND SHALL NOT BE HAND WRITTEN. <br />x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE <br />SPECIFIED. <br />x DO NOT COVER EXISTING MANUFACTURER LABELS. <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): CEC 2019: 705.12(D)(3), <br />NEC 2017: 705.12(D)(3), NEC 2011: <br />705.12(D)(4) <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2019: <br />705.12(D)(2)(3)(c), NEC 2017: <br />705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND <br />BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), <br />690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 <br />ELECTRICAL SHOCK HAZARD <br />LABEL LOCATION: <br />INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2019: 690.5(C), NEC 2017: 690.5(C), <br />NEC 2011: 690.5(C) <br />PHOTOVOLTAIC AC DISCONNECT <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />PER CODE(S): CEC 2019: 690.35(F), NEC <br />2017: 690.35(F), NEC 2011: 690.35(F) <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL <br />(IF APPLICABLE). <br />PER CODE(S): CEC 2019: 690.17(E), NEC 2017: 690.17(E), <br />NEC 2011: 690.17(4) <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF <br />APPLICABLE). <br />PER CODE(S): CEC 2019: <br />705.12(D)(2)(3)(b), NEC 2017: <br />705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) <br />WARNING <br />WARNING! <br />WARNING ! WARNING! <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL LOCATION: <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53, NEC <br />2011: 690.53! <br />! <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />AT: MAIN SERVICE PANEL & UTILITY METER <br />AC DISCONNECT,INVERTER <br />CAUTION: <br />MULTIPLE SOURCES OF POWER <br />(N) COMBINER BOX <br />(N) AC DISCONNECT <br />(E) MAIN SERVICE PANEL <br />(E) UTILITY METER <br />WEST CENTRAL AVENUE <br />729 W Central Ave <br />02/16/23