Laserfiche WebLink
Ex <br />p <br />e <br />d <br />i <br />t <br />e <br />d <br /> <br />P <br />e <br />r <br />m <br />i <br />t <br /> <br />P <br />r <br />o <br />c <br />e <br />s <br />s <br /> <br />f <br />o <br />r <br /> <br />P <br />V <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />s <br /> <br />4 <br />MICRO-INVERTER ELECTRICAL DIAGRAM <br />Contractor Name, <br />Address and Phone:One-Line Standard Electrical Diagram <br />for Micro-Inverter PV Systems <br />Site Name: <br />Site Address: <br />System AC Size: <br />SIZE FSCM NO DWG NO REV <br />SCALE NTS Date: SHEET <br />Drawn By: <br />Checked By: <br />DESCRIPTION OR CONDUCTOR TYPE <br />USE-2 or PV WIRE <br />GEC EGC X ALL THAT APPLY <br />EXTERIOR CABLE LISTED W/ INV. <br />THWN-2 or XHHW-2 or RHW-2 <br />GEC EGC X ALL THAT APPLY <br />NO DC GEC IF 690.35 SYSTEM <br />THWN-2 or XHHW-2 or RHW-2 <br />GEC EGC X ALL THAT APPLY <br />TAG <br />1 <br />2 <br />3 <br />4 <br />5 <br />CONDUIT AND CONDUCTOR SCHEDULE <br />COND. <br />GAUGE <br />#10 <br />NUMBER OF <br />CONDUCTORS <br />6 <br />CONDUIT <br />TYPE <br />EMT <br />CONDUIT <br />SIZE <br />3/4" <br />DESCRIPTION <br />PV DC or AC MODULE <br />DC/AC INVERTER (MICRO) <br />J-BOX (IF USED) <br />PV ARRAY <br />AC COMB. PANEL (IF USED) <br />GEN METER (IF USED) <br />AC DISCONNECT (IF USED) <br />SERVICE PANEL <br />TAG <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />PART NUMBER NOTES <br />FOR UNUSED MODULES <br />PUT "N/A” in BLANK ABOVE <br />1 <br />1 3 <br />2 <br />3 <br />EQUIPMENT SCHEDULE <br />2 <br />_____ <br />MICRO-INVERTERS <br />IN BRANCH- <br />CIRCUIT <br />MOD <br />____ <br />DC <br />AC <br />MOD <br />____ <br />DC <br />AC <br />MOD <br />____ <br />DC <br />AC <br />MOD <br />____ <br />DC <br />AC <br />MOD <br />____ <br />DC <br />AC <br />MOD <br />____ <br />DC <br />AC <br />J-BOX <br />4 <br />AC DISCO <br />M <br />BUILDING <br />GROUNDING <br />ELECTRODE <br />G <br />M <br />UTILITY <br />SERVICE <br />MAIN SERVICE PANEL <br />MAIN <br />OCPD <br />INVERTER <br />OCPD <br />6 <br />7 <br />8 <br />5 <br />4 <br />5 <br />G <br />SEE GUIDE APPENDIX D FOR <br />INFORMATION ON MODULE AND <br />ARRAY GROUNDING <br />AC COMBINER <br />PANEL <br />G <br />____ <br />MICRO-INVERTERS <br />IN BRANCH- <br />CIRCUIT <br />29 <br />29 <br />1 <br />3 <br />1 <br />0 <br />1 <br />1 <br />CANADIAN SOLAR CS3N-400MS 400W <br />JUNCTION BOX 600V, NEMA 4 UL LISTED <br />COMBINER PANEL ENPHSE IQ COMBINER 4 (X-IQ-AM1-240-4) <br />LOCABLE BLADE TYPE NON-FUSIBLE AC DISCONNECT NEMA 3R 60A-2P 120/240VAC <br />225A MAIN SERVICE PANEL WITH 200A MAIN BREAKER <br />1 2 <br />1 2 <br />14 <br />15 <br />ADAM MENDOZA <br />2203 FREEMAN ST, SANTA ANA, CA 92706 <br />8.410 KW AC <br />#6 <br />#10 <br />#10 <br />#8 <br />#8 <br />#6 <br />#8 <br />1 <br />6 <br />6 <br />1 <br />1 <br />3 <br />1 <br />EMT <br />EMT <br />EMT <br />EMT <br />EMT <br />EMT <br />EMT <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />801 E Clemensen <br />Ave02/23/23