To scale on 24x36 paper <br />X___________________________ <br />GENERAL NOTES:PROJECT SCOPE:DRAWING INDEX PERMITTING / PLANNING NOTES: <br />PROJECT ADDRESS AERIAL PHOTO:PROJECT TEAM: <br />THIS INSTALLATION CONSISTS OF A NEW ROOFMOUNTED PHOTOVOLTAIC (PV) SYSTEM. THE PV SYSTEM <br />IS STATIC MOUNTED. <br />THIS SYSTEM WILL BE INTERCONNECTED TO AND WILL BE OPERATED IN PARALLEL WITH THE ELECTRIC <br />GRID PER THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND UTILITY INTERCONNECT <br />AGREEMENT <br />CONDITIONS OF APPROVAL: <br />1. ALL CONSTRUCTION SHALL OCCUR BETWEEN THE HOURS OF 7AM & 7PM, EXCEPT FOR THE PURPOSE <br />OF EMERGENCIES. <br />1. THIS PV SYSTEM INSTALLATION IS SUBJECT TO INSPECTION BY THE AUTHORITY HAVING <br />JURISDICTION <br />2. THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODE VERSIONS: <br />2022 CALIFORNIA BUILDING CODE (CBC 2022) <br />2022 CALIFORNIA ELECTRIC CODE (CEC 2022) <br />2022 CALIFORNIA FIRE CODE (CFC 2022) <br />2022 CALIFORNIA ENERGY CODE (CEnC 2022) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG 2022) <br />2022 CALIFORNIA PLUMBING CODE (CPC 2022) <br />2022 CALIFORNIA MECHANICAL CODE (CMC 2022) <br />3. MODULE LEVEL RAPID SHUT-DOWN EQUIPMENT USED WHICH MEETS 690.12 RAPID SHUTDOWN <br />REQUIREMENTS. <br />4. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY <br />RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH <br />ADMINISTRATION. <br />5. ELECTRICAL EQUIPMENT SHALL BE LISTED OR CERTIFIED BY A RECOGNIZED ELECTRICAL TESTING <br />LABORATORY OR APPROVED BY THE DEPARTMENT. <br />6. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES, TRANSFORMERS, <br />VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ECT.) OR TO THE LOCATION OF THE HOOK-UP. THE <br />CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE <br />LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL <br />EXPENSES. <br />7. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE <br />AVAILABLE AT THE JOB SITE. <br />8. INSTALLATION OF THE PV SYSTEM IN PARALLEL WITH THE UTILITY POWER SHALL BE <br />INSTALLED ONLY BY QUALIFIED PERSONS. 705.6. <br />9. THE OUTPUT CHARACTERISTICS OF THE PV SYSTEM SHALL BE COMPATIBLE WITH THE <br />VOLTAGE, WAVE SHAPE, AND FREQUENCY OF THAT OF THE UTILITY OUTPUT. 705.14. <br />10. INTERCONNECTED ELECTRIC POWER PRODUCTION SOURCES SHALL BE GROUNDED IN <br />ACCORDANCE WITH ARTICLE 250. 705.50. <br />SITE CONTACT: <br />CONTRACTOR: <br />Confidentiality Statement: <br />VICINITY MAP: <br />1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 2022 TITLE 24 OF THE <br />CALIFORNIA BUILDING CODE, CMC,CPC. CEC AND ALL APPLICABLE LOCAL CODES, <br />ORDINANCES, AND STATE AMENDMENTS. <br />2. THE CONTRACTOR SHALL CHECK ALL DRAWINGS IMMEDIATELY UPON THEIR RECEIPT <br />AND SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. <br />ALL ARCHITECTS AND ENGINEERS SHALL BE NOTIFIED OF ANY DISCREPANCIES. <br />3. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY <br />SHOWN, NOTED, OR APPROVED BY ALL. NOTCH DETAILS, IF PROVIDED ARE FOR <br />GENERAL GUIDANCE ONLY. ALL SHALL BE CONTACTED TO APPROVE LOCATIONS OF <br />PROPOSED NOTCHES. <br />4. CONNECTIONS AND IMPLIED CONSTRUCTION ASSEMBLIES THAT ARE NOT <br />SPECIFICALLY DESCRIBED OR DETAILED SHALL BE CONSTRUCTED USING STANDARD <br />CONSTRUCTION PRACTICES IN COMPLIANCE WITH THE GOVERNING CODES AND <br />ORDINANCES. <br />5. WHEN DETAILS LABELED "TYPICAL” OR "SIMILAR" ARE GIVEN ON DRAWINGS, THE <br />CONTRACTOR SHALL APPLY THE INTENT OF THE DETAIL TO THAT SPECIFIC CONDITION. <br />6. WRITTEN INFORMATION AND DIMENSIONS SHALL HAVE PRECEDENCE OVER GRAPHIC <br />INFORMATION. DO NOT SCALE. <br />7. DRAWINGS AND SPECIFICATIONS FOR THIS WORK HAVE BEEN PREPARED IN <br />ACCORDANCE WITH GENERALLY ACCEPTED STANDARDS OF PRACTICE TO MEET THE <br />MINIMUM REQUIREMENTS DF THE CURRENT EDITION DF THE CBC. ANY DISCREPANCIES <br />ON THE PLANS OR ANY DE\/IATIONS FROM THE PLANS WHICH ARE NECESSITATED BY <br />FIELD CONDITIONS OR ANY CONDITION DIFFERENT FROM THOSE INDICATED ON THE <br />PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. ALL WORK IS TO <br />BE COORDINATED SO THAT COOPERATION BETWEEN THE TRADES WHERE REQUIRED IS <br />ACCOMPLISHED. <br />8. CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR THE ORDER AND <br />MEANS OF CONSTRUCTION AND ALL TEMPORARY BRACING AND ERECTION DURING <br />CONSTRUCTION. <br />9. APPROVALS BY BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM THE PLANS AND SPECIFICATIONS. <br />10. ALL WORK SHALL CONFORM TO TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR). <br />11. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS <br />AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL <br />ORDINANCES. <br />2/24/2023 7:37:03 PM <br />Title Sheet <br />FO <br />S <br />T <br />E <br />R <br /> <br />P <br />R <br />I <br />N <br />T <br />I <br />N <br />G <br /> <br />C <br />o <br />70 <br />0 <br /> <br />E <br /> <br />A <br />l <br />t <br />o <br />n <br /> <br />A <br />v <br />e <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />T101 <br />FOSTER PRINTING Co <br />700 E Alton Ave Santa Ana CA, 92705 <br />SOLAR ELECTRIC SYSTEM PROJECT - 455.220kW DC STC RATING / 422.677kW AC CEC RATING <br />TIM BLACKBURN <br />ADDRESS: 700 E ALTON AVE <br />SANTA ANA, CA 92705 <br />PHONE: 714-731-2000 <br />SOLAR ELECTRIC SYSTEM <br />THIS PROJECT ENTAILS THE INSTALLATION OF A PHOTOVOLTAIC SYSTEM AT FOSTER PRINTING Co THE <br />SYSTEM WILL NOT BE A NET ELECTRICITY EXPORTER TO THE UTILITY GRID. <br />This drawing is the property of RENEWABLE <br />ENERGY PARTNERS. This information is <br />confidential and is to be used only in connection <br />with work described by RENEWABLE ENERGY <br />PARTNERS. No part is to be discolosed to <br />others without written permission from <br />RENEWABLE ENERGY PARTNERS <br />RENEWABLE ENERGY <br />PARTNERS <br />LIC # 989857 <br />EXP: 01/31/2024 <br />RENEWABLE ENERGY <br />PARTNERS <br />RENEWABLE ENERGY PARTNERS <br />170 MAPLE ST, STE 105 CORONA, CA <br />92881 <br />TEL: 855-519-6633 <br />LIC # 989857 <br />RENEWABLE ENERGY PARTNERS <br />www.RENEWEPI.com <br />855-519-6633 <br />170 MAPLE ST, STE 105 <br />CORONA, CA 92881 <br />Sheet #Sheet Name <br />T101 Title Sheet <br />T102 Notes <br />A101 Site Plan <br />C-1.0 Cover Page <br />M-1.0 Site Plan <br />M-2.0 Roof Plan <br />M-3.1 Load Array 1 <br />M-3.2 Load Array 2 <br />M-3.3 Load Array 3 <br />M-3.4 Load Array 4 <br />M-3.5 Load Array 5 <br />M-4.0 Paver Layout <br />M-4.1 Paver Array 1 <br />M-4.2 Paver Array 2 <br />M-4.3 Paver Array 3 <br />M-4.4 Paver Array 4 <br />M-4.5 Paver Array 5 <br />E101 Electrical Layout <br />E201 Single Line Diagram <br />E301 Signage <br />SP101 Spec Sheets <br />SP102 Spec Sheets <br />MODULES: <br />(843) CSI SOLAR CO., LTD 540W SOLAR MODULES <br />CS6W-540MB-AG <br />PTC: 508 Wptc <br />INVERTERS: <br />(6) SUNGROW 60KW, INVERTERS <br />SG60CX-US [480V] [SI1] <br />CEC WEIGHTED EFFICIENCY: 98.5% <br />RAPID SHUTDOWN SPECS: <br />(432) TIGO TS4-A-2F <br />ARRAY LOCATIONS <br />PROJECT <br />LOCATION <br />PROJECT LOCATION <br />APN:411-152-08 <br />No <br />. <br />De <br />s <br />c <br />r <br />ip <br />ti <br />o <br />n <br />Da <br />t <br />e <br />Bldg# 101114289 JLo <br />Elec# 20179063 MSmith <br />Issued 06/02/23 <br />700 E Alton Ave - <br />101114289 & <br />2017906306/06/23