My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
831 N Westwood Ave - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Westwood Ave
>
831 N Westwood Ave
>
831 N Westwood Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:09:17 PM
Creation date
6/1/2025 12:09:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20179917
101115467
Full Address
831 N Westwood Ave
Document Relationships
101115467 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Westwood Ave\831 N Westwood Ave
20179917 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Westwood Ave\831 N Westwood Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV SYSTEM <br />AS INDICATED <br />OCTOBER 15, 2022 <br />JESUS MUNOZ <br />831 N WESTWOOD AVE, <br />SANTA ANA, CA 92703 <br />Drawn By : Narek A. <br />Clean Energy Solutions Inc. <br />Address: <br />1055 West 7th Street <br />33rd Floor, Los Angeles, <br />CA 90017 <br />Phone Number: <br />(800)994 1134 <br />Lic# 998787 <br />Class C-10 <br />CONTRACTOR <br />3 <br />FROM PV MODULES TO JBOX <br />FROM JBOX TO INVERTER <br />(4) <br />WIRE SIZE <br />CALCULATIONS <br />1 <br />(1) #6 AWG BARE CU EGC, <br />2 <br /> #8 AWG CU EGC, <br />(3) <br />3 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT (A) <br /> TEMPERATURE FACTOR <br /> TEMPERATURE ADJUSTMENT (A) <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br /> MAXIMUM POWER (W) <br /> PEAK PWR TRACKING VOLTAGE (V) <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> SHORT CIRCUIT CURRENT (A) <br /> ADJUSTED CONDUCTOR AMPACITY (A) <br />1.25 <br />1.25 <br />1.25 <br />0.91 <br />(4) <br />(1) <br /> Pmax (PTC Rating) <br />380 <br />99 % 1 <br /> #10 AWG THWN-2 <br />SOLAR EDGE SE5000H-US RGM SI1 (CEC) <br />21.0 * 1.25 / 0.91 <br />21.0 <br />28.8 <br />21.0 * 1.25 26.3 <br />1 1/2'' <br /> (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />0.8ADJST. FACTOR (4 thru 6 WIRES) <br />FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS <br />3/4'' EMT TYPE CONDUIT <br />3/4'' EMT TYPE CONDUIT <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />30A <br />* /* 1.25 *1.259 390 380 14.4 <br />//14.4 0.58 0.8 31.0 <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br /> * 17 390 6.63 KW <br />** 17 369.1 0.99 6.21 KW <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS COEFFICIENT <br />200A <br />200A <br />240A <br />200A ''MB'' + 30A "SOLAR" = 230A ≤ 240A MAX <br />FROM INVERTER TO MAIN SERVICE PANEL <br /> CONSIDER CONTINUOUS (A) <br /> MAX NUMBER OF MODULES IN STRING 9 <br />#10 AWG PV-WIRE <br />17 <br />CS3N-390MS 390 W <br /> 369.1 W <br />390 <br />831 N Westwood <br />Ave06/15/23
The URL can be used to link to this page
Your browser does not support the video tag.