My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
805 E Clemensen Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Clemensen Ave
>
805 E Clemensen Ave
>
805 E Clemensen Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:09:21 PM
Creation date
6/1/2025 12:09:07 PM
Metadata
Fields
Template:
Plan
Permit Number
20179180
101114451
Full Address
805 E Clemensen Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />Nathan Draeger <br />DESIGNER: <br />DESIGN MGR: <br />Tino Marufu <br />NEW PV SYSTEM: 3,240 DC / 3000 AC <br />Lillian Granillo <br />805 Clemensen Ave, Santa Ana, CA 92705 <br />APN: 39641115 <br />3/13/2023 <br />DATE:TIME: <br />05:05 PM <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />NOTES SHEET <br />P2 <br />1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM <br />SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURES SPECIFICATIONS AND THE 2022 <br />CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 <br />AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND 2022 <br />CALIFORNIA FIRE CODE. <br />2. CONTRACTORS SHALL BE PRESENT DURING ALL <br />INSPECTIONS. <br />3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL <br />NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED <br />WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS <br />SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. <br />4. A LADDER SHALL BE PROVIDED AND SECURED TO THE <br />STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER <br />NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE <br />DURING ALL INSPECTIONS. <br />5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST <br />OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL <br />NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br />INSTALLED PER THE LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] <br />7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. <br />8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON <br />THE PHOTOVOLTAIC SYSTEM <br />9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, <br />MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS <br />AND INSTALLATION INSTRUCTIONS. THE PV SOLAR <br />SYSTEM WILL BE INTERCONNECTED AND OPERATED IN <br />PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE <br />REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. <br />THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE <br />WITH CEC 690.12 (RAPID SHUTDOWN). <br />JURISDICTION NOTES ELECTRICAL NOTES <br />CONSTRUCTION NOTES <br />UTILITY NOTES <br />1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />2. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. <br />3. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. <br />4. THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL <br />VENTS. <br />5. A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA <br />REGULATIONS. <br />6. MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL <br />ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS <br />ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. <br />7. ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED <br />IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S <br />INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE <br />BUILDING STRUCTURE. <br />8. CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE <br />LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS <br />POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND <br />MAXIMIZE VENTILATION OPPORTUNITIES. <br />9. WE WILL MAINTAIN 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. <br />10. CONDUIT RUNS TO BE DETERMINED IN FIELD <br />1. PV SOURCE CIRCUIT(S) ARE TO BE <br />SUNLIGHT-RESISTANT PV-WIRE AS <br />PERMITTED BY CEC 690.31(B). <br />2. ALL DIRECT CURRENT CIRCUITS ARE TO BE <br />INSTALLED IN METAL RACEWAY FROM THE <br />POINT OF PENETRATION OF THE SURFACE OF <br />THE BUILDING OR STRUCTURE TO THE MAIN <br />SERVICE PANEL AS MANDATED BY CEC <br />690.31(E). <br />3. WEATHERPROOF J-BOX – NEMA 3R. <br />4. ROOFTOP CONDUIT SHALL BE A MINIMUM <br />OF 1" ABOVE THE ROOF SURFACE. <br />5. ALL WORK SHALL COMPLY WITH THE 2022 <br />CALIFORNIA ELECTRICAL CODE (C.E.C.) AND <br />ALL OTHER LOCAL CODES AS APPROVED BY <br />THE AUTHORITY HAVING JURISDICTION. <br />CODE REFERENCES <br />· 2022 CALIFORNIA BUILDING CODE <br />· 2022 CALIFORNIA RESIDENTIAL CODE <br />· 2022 CALIFORNIA ELECTRICAL CODE <br />· 2022 CALIFORNIA FIRE CODE <br />· 2022 CALIFORNIA MECHANICAL CODE <br />· 2022 CALIFORNIA GREEN CODE <br />· 2022 CALIFORNIA PLUMBING CODE <br />· 2022 CALIFORNIA ENERGY CODE <br />· ANY OTHER LOCAL AND MUNICIPAL CODES <br />1. ALL EXPOSED ROOF WIRING SHALL BE USE-2 TYPE <br />RATED FOR (90 DEGREE C) WET CONDITIONS. OTHER <br />OUTDOOR WIRING SHALL BE COPPER THWN-2 TYPE <br />RATED FOR (90 DEGREE C) APPLICATION IN EMT <br />CONDUIT. <br />2. WHERE METALLIC CONDUIT CONTAINING DC <br />CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL <br />BE IDENTIFIED AS <br />"CAUTION: SOLAR CIRCUIT" EVERY 5 FEET. <br />3. A DC DISCONNECTING MEANS SHALL BE INSTALLED AT <br />A READILY ACCESSIBLE LOCATION EITHER OUTSIDE <br />OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST <br />TO THE POINT OF ENTRANCE OF THE SYSTEM <br />CONDUCTORS AS PER SECTION 690-14 OF THE CEC. <br />4. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL <br />NOT EXCEED 6'-7" PER NEC240.24 <br />5. WORKING CLEARANCE AROUND THE EXISTING <br />ELECTRICAL EQUIPMENT AS WELL AS THE NEW <br />ELECTRICAL EQUIPMENT WILL BE IN ACCORDANCE <br />WITH NEC 1010.26 <br />6. WHERE DC CONDUCTORS ARE RUN INSIDE THE <br />BUILDING (OR ATTIC). THEY SHALL BE CONTAINED IN A <br />METAL RACEWAY. (NEC 690.31E) <br />7. MAKE SURE TO MEASURE THE LINE-TO-LINE AND THE <br />LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE <br />ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY <br />SOLAR EQUIPMENT. <br />8. (WIRE NUT ARE NOT ALLOWED ANY WHERE IN THE PV <br />SYSTEM PER INSTALLATION GUIDE AND CEC SECTION <br />110.3[8]. <br />9. AII PLAQUES AND SIGNAGE SHALL BE INSTALLED PER <br />2013 CEC AND 2011 NEC. <br />10. AS PER CEC 705.10 "A PERMANENT PLAQUE OR <br />DIRECTORY, DENOTING ALL ELECTRICAL POWER <br />SOURCES ON THE PREMISES, SHALL BE INSTALLED AT <br />BEACH SERVICE EQUIPMENT LOCATION AND AT <br />LOCATIONS OF ALL ELECTRICAL POWER PRODUCTION <br />SOURCES CAPABLE OF BEING INTERCONNECTED <br />11. THE GEC/EGC SHALL BE CONTINUOUS, OR WHEN <br />SPLICED, THE SPLICE SHALL BE MADE BY <br />IRREVERSIBLE CRIMP. <br />12. EQUIPMENT GROUNDING CONDUCTORS AND DEVICES <br />SHALL COMPLY WITH CEC 690.43(A)-(F). EXPOSED <br />NON-CURRENT-CARRYING METAL PARTS OF A MODULE <br />FRAMES, EQUIPMENT AND CONDUCTOR ENCLOSES <br />SHALL BE GROUNDED IN ACCORDANCE WITH CEC <br />250.134 OR CEC 250.136(A). <br />13. BONDING BUSHINGS WILL BE LOCATED AT EQUIPMENT <br />ENCLOSURES. <br />14. 1NTERIOR CONDUIT TO BE RAN A MINIMUM 18 INCHES <br />BELOW ROOF DECKING. <br />GENERAL NOTES <br />UTILITY HAS 24 HR UNRESTICTED ACCESS <br />TO ALL PHOTOVOLTAIC SYSTEM <br />COMPONENTS LOCATED AT SERVICE <br />ENTRANCE <br />WORKSPACE IN FRONT OF AC ELECTRICAL <br />SYSTEM COMPONENTS SHALL BE IN <br />ACCORDANCE WITH APS AND NEC <br />REQUIREMENTS. FOR APS REQUIREMENTS, <br />REFERENCE SECTION 300 OF THE APS ESRM <br />AND SECTION 8.2 OF THE APS <br />INTERCONNECTION REQUIREMENTS <br />REFERENCE SECTION 301.15 OF THE APS <br />ESMR FOR ELECTRIC METER SEPERATION <br />BETWEEN WATER AND GAS <br />JURISDICTION STAMPS: <br />805 E Clemensen <br />Ave03/29/23
The URL can be used to link to this page
Your browser does not support the video tag.