Laserfiche WebLink
<br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) <br /> <br /> <br /> <br />Appendix 2: Ratings & Principle Characteristics: <br />➢ Ratings: <br />Models 1707000-xx-y <br />Rated AC Output Power (W) 11500, 10000, 7680, 5750 <br />Rated AC Input Power (W) Charging 5000 <br />Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 <br />Max. Continuous Output PV to AC <br />Power Off-Grid (W) 15400 <br />Max. Cont. Input Power (W) Charging 5000 <br />AC Input / Output Voltage <br />(VL-L) 240 <br />AC Output Frequency <br />(Hz) 60 <br />Max. Cont. Output Current (A) 48, 4 1.6, 32, 24 <br />Max. Cont. Input Current (A) Charging 20.83 <br />Apparent Power rating (VA) 11500, 10000, 7680, 5750 <br />Apparent Power rating (VA) Charging 5000 <br />Normal Category A, B <br />Abnormal Category II, III <br /> <br />➢ Communication Protocol: IEEE 2030.5 protocol <br /> <br />➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 <br />➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= <br />➢ Grid Support Function Parameters: <br />Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid <br />support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. <br /> <br />➢ UL 1998 and CSA C22.2#0.8 Evaluation: <br /> <br />ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 <br />Compliant* <br />Date of evaluation <br />HVP / -E V2 51705DB5 Yes Apr-19-2024 <br />PWS / -3F V2 34204954 Yes Apr-19-2024 <br />PWS / -1F V2 B3C1375B Yes Apr-19-2024 <br />PWS / -D V2 43FEF523 Yes Apr-19-2024 <br />*Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. <br />• List of all UL1998 and UL 991 functions are as follow: <br />o Overcharge <br />o Over-discharge <br />o Over Temperature <br />o Over current <br />o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) <br />o AFCI (UL 1699B) <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) <br /> <br /> <br />