My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
901 N Westwood - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Westwood Ave
>
901 N Westwood Ave
>
901 N Westwood - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:08 PM
Creation date
6/1/2025 12:11:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20185855
Full Address
901 N Westwood Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) <br /> <br />Table 3B: Test List -2 <br />Test Description <br />CSA <br />C22.2#107.1:2016 <br />Ed. 4 CSA C22.3#9:2020 Ed 2 <br />Screw Tightening Torque Test 3.6.3 -- <br />Impedance Test 105.1/10.5.2 -- <br />Continuity Test 4.1 -- <br />Output Power Factor 4.2 -- <br />Voltage Harmonics for stand alone 15.3.2.1 -- <br />Frequency 10.5.4 -- <br />Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- <br />Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 <br />Flicker -- 7.2.2 / 8.3.13 <br />Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) <br /> <br />Appendix 4: Revision Summary <br /> <br />Date / <br />Project Engineer Comments <br />15-Feb-2023 Dipesh Patel Original issue date <br />8-Mar-2023 / <br />G104200718 <br />Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards <br />24-Mar-2023/ <br />G104200718 <br />Dipesh Patel Added UL 1973 standard. <br />Added normal and abnormal category in ratings table. <br />18-Apr-2023 / <br />G104200718 <br />Dipesh Patel Added additional factory settable nameplate ratings rated output active <br />power (W): 9600, 7680, 5750; Max. Continuous output power (W): <br />9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent <br />Power rating (VA): 9600, 7680, 5750 <br />Added Puerto Rico Interconnection regulation as it refers to UL 1741 <br />and IEEE 1547-2018. <br />1-May-2024 / <br />G104514208 <br />Mukund Rana <br /> <br />A) Added standards. <br />Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] <br />Interconnection of Distributed Energy Resources and Electricity Supply <br />Systems [CSA C22.3#9:2020 Ed.2] <br />Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] <br />Interconnection of Distributed Energy Resources and Electricity Supply <br />Systems [CSA C22.3#9:2020 Ed.2] <br />B) Update CSA C22.2#0.8 standard <br />C) added Table 3B: Test List -2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.