Laserfiche WebLink
Template_version_v5_2025.04.08 <br />PAGE <br />REV: A 4/13/2025 <br />JOSE GUERRERO <br />901 WESTWOOD AVE SANTA <br />ANA CA 92703 <br />PROJECT NUMBER: <br /> 109R-901GUER2 <br />SHEET <br />DESIGNER: <br />JOHNPAUL JOSHY <br />CUSTOMER RESIDENCE: <br />TEL. (657) 731-4773 <br />APN: 405-231-22 <br />(415) 580-6920 ex3 <br />Template_version_v5_2025.04.08 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C) <br />120/240 <br />520 VDCMAXIMUM ESS DC VOLTAGE:60 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />SIGNAGE <br />PV-5.0 <br />#ESTAMP <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2), <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC <br />2022: 690.13(B) <br />! <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC <br />2022: 705.12(C) <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND <br />ANY PANEL THAT UTILIZES "THE SUM <br />OF BREAKERS RULE". <br />PER CODE(S): NEC 2020: 705.12 (B)(3)(3), <br />CEC 2022: 705.12 (B)(3)(3) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 48 AMPS <br /> 240 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT