My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
929 E Jonquil Rd - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Jonquil Rd
>
929 E Jonquil Rd
>
929 E Jonquil Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:19 PM
Creation date
6/1/2025 12:11:05 PM
Metadata
Fields
Template:
Plan
Permit Number
20181440
101117388
Full Address
929 E Jonquil Rd
Document Relationships
101117388 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Jonquil Rd\929 E Jonquil Rd
20181440 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Jonquil Rd\929 E Jonquil Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Data Sheet <br />Enphase Q Cable Accessories <br />REGION: Americas <br />Enphase <br />Q Cable Accessories <br />To learn more about Enphase offerings, visit enphase.com <br />The Enphase Q Cable ™ and accessories are part of <br />the latest generation Enphase IQ System ™. These <br />accessories provide simplicity, reliability, and faster <br />installation times. <br />Enphase Q Cable <br />•Two-wire, double-insulated Enphase Q Cable <br />is 50% lighter than the previous generation <br />Enphase cable <br />New cable numbering and plug and play <br />connectors speed up installation and simplify <br />wire management <br />•Link connectors eliminate cable waste <br />Field-Wireable Connectors <br />•Easily connect Q cables on the roof without <br />complex wiring <br />Make connections from any open connector <br />and center feed any section of cable within <br />branch limits <br />•Available in male and female connector types <br />9 EN PHASE. <br />Enphase Q Cable Accessories <br />CONDUCTOR SPECIFICATIONS <br />Certification <br />Flame test rating <br />Compliance <br />Conductor type <br />Disconnecting means <br />UL3003 (raw cable), UL 9703 (cable assemblies), DG cable <br />FT4 <br />RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States <br />THHN/THWN-2 dry/wet <br />The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break <br />disconnect required by NEC 690. <br />Q CABLE TYPES/ ORDERING OPTIONS <br />Connectorized Models Size/ Ma x Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box <br />Q-12-10-240 <br />Q-12-17-240 <br />Q-12-20-200 <br />12 AWG / 277 VAC <br />12 AWG / 277 VAC <br />12 AWG / 277 VAC <br />EN PHASE Q CABLE ACCESSORIES <br />Name Model Number <br />Raw Q Cable <br />Field-wireable connector (male) <br />Field-wireable connector (female) <br />Cable Clip <br />Q-12-RAW-300 <br />Q-CONN-10M <br />Q-CONN-10F <br />Q-CLIP-100 <br />Q-DISC-10 <br />Q-SEAL-10 <br />Q-TERM-10 <br />ECA-EN4-S22 <br />Disconnect tool <br />Q Cable sealing caps (female) <br />Terminator <br />En phase EN4 to MC4 adaptor' <br />Enphase EN4 non-terminated adaptor' ECA-EN4-FW <br />En phase EN4 to MC4 adaptor (long)' ECA-EN4-S22-L <br />Replacement DC Adaptor (MC4) Q-DCC-2 <br />Replacement DC Adaptor (UTX) Q-DCC-5 <br />1. Qualified per UL subject 9703. <br />TERMINATOR <br />Terminator cap for unused cable <br />ends, sold in packs of ten <br />(Q-TERM-10) <br />DISCONNECT TOOL <br />Plan to use at least one per <br />installation, sold in packs of ten <br />(Q-DISC-10) <br />To learn more about Enphase offerings, visit enphase.com <br />1.3 m (4.2 ft) <br />2.0 m (6.5 ft) <br />2.3 m (7.5 ft) <br />Description <br />Portrait <br />Landscape (60-cell) <br />Landscape (72-cell) <br />240 <br />240 <br />200 <br />300 meters of 12 AWG cable with no connectors <br />Make connections from any open connector <br />Make connections from any Q Cable open connector <br />Used to fasten cabling to the racking or to secure looped cabling <br />Disconnect tool for Q Cable connectors, DC connectors, and AC module mount <br />One needed to cover each unused connector on the cabling <br />Terminator cap for unused cable ends <br />Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S <br />SOLARLOK). 150mm/5.9" to MC4. <br />For field wiring of UL certified DC connectors. EN4 (TE PV4-S SOLARLOK) to <br />non-terminated cable. 150mm/5.9" <br />Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split <br />cell modules or PV modules with short DC cable. 600mm/23.6" <br />DC adaptor to MC4 (max voltage 100 VDC) <br />DC adaptor to UTX (max voltage 100 VDC) <br />SEALING CAPS <br />Sealing caps for unused aggregator <br />and cable connections <br />(Q-BA-CAP-10 and Q-SEAL-10) <br />CABLE CLIP <br />Used to fasten cabling to the racking <br />or to secure looped cabling, sold in <br />packs of one hundred (Q-CLIP-100) <br />© 2020 En phase Energy. All rights reserved. En phase, the En phase logo, En phase IQ 7 A, En phase IQ Battery, Enphase Enlighten, En phase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. Q EN pH AS E 2020-06-26 '-J • <br />929 E Jonquil Rd - <br />2018144011/27/2023
The URL can be used to link to this page
Your browser does not support the video tag.