Laserfiche WebLink
IQ System Controller 3/3G HiiMhdi <br />MODEL NUMBER DESCRIPTION <br />SC200D111C240US01 <br />SC200G111C240US01 <br />WHAT'S IN THE BOX <br />IQ System Controller 3/3G <br />System Shutdown Switch <br />Wall-mounting bracket <br />4-pole circuit breaker <br />Accessories kit <br />OPTIONAL ACCESSORIES AND REPLACEMENT PARTS <br />CT-200-SPLIT <br />CT-200-CL AMP <br />Main or load circuit breakers (order separately, as needed)• <br />Distributed energy resource (DER) circuit breakers (order separately, as <br />needed)5 <br />EP200G-HNDL-R1 <br />CTRL-SC3-NA-01 <br />ALTERNATE DER CIRCUIT BREAKERS <br />GE/ABB <br />Siemens <br />Siemens (quad breaker) <br />ELECTRICAL SPECIFICATIONS <br />Nominal voltage/Range (L-L) <br />Voltage measurement accuracy <br />Auxiliary (dry) contact for load control, excess PV control, and generator <br />two-wire control <br />Nominal frequency/Range <br />Frequency measurement accuracy <br />Maximum continuous current rating <br />Maximum input overcurrent protection device <br />Maximum output overcurrent protection device <br />Maximum overcurrent protection device rating for generator circuit <br />Maximum overcurrent protection device rating for storage circuit <br />IQ System Controller 3 streamlines the grid-independent capabilities of PV and storage <br />installations . Integrates hold-down capability. Supports IQ Battery 5P units up to 40 kWH (without <br />PCS*) and 80 kWh (with PCS*). Does not support generator integration <br />IQ System Controller 3G streamlines the grid-independent capabilities of PV and storage <br />installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 20 kWH (without <br />PCS*) and 40 kWh (with PCS*). Supports generator integration <br />Includes neutral-forming transformer (NFT) and microgrid interconnect device (MID) <br />Includes pre-wired red, black, orange, and purple 12 AWG wire (EP200G-NA-02-RSD) <br />Screws provided in the accessories kit for mounting <br />Pre installed Quad breaker (BRK-20A40A-4P-240V), 20 A-40 A, 10 kAIC, Eaton BQC220240' <br />IQ System Controller 3/3G literature kit, including labels, CTRL headers, screws, filler plates, and <br />Quick Install Guide (QIG) (EP200G-LITKIT) <br />200 A split core current transformers for metering (accuracy: ±2.5%)3 <br />200 A clamp-type current transformers for metering (accuracy: ±2.5%)3 <br />BRK-100A-2P-240V : 2-pole, 100A, 25kAIC, CSR2100N or CSR2100 <br />BRK-125A-2P-240V: 2-pole, 125A, 25kAIC, CSR2125N <br />BRK-150A-2P-240V: 2-pole, 150A, 25kAIC, CSR2150N <br />BRK-175A-2P-240V: 2-pole, 175A, 25kAIC, CSR2175N <br />BRK-200A-2P-240V: 2-pole, 200A, 25kAIC, CSR2200N <br />BRK-20A-2P-240V-B: 2-pole, 20 A, 10 kAIC, BR220B/BR220 <br />BRK-30A-2P-240V-B: 2-pole, 30 A, 10 kAIC, BR230 <br />BRK-40A-2P-240V-B: 2-pole, 40 A, 10 kAIC, BR240B/BR240 <br />BRK-60A-2P-240V: 2-pole, 60 A, 10 kAIC, BR260 <br />BRK-80A-2P-240V: 2-pole, 80 A, 10 kAIC, BR280 <br />IQ System Controller 3/3G installation handle kit (order separately) <br />Control cable, 500 ft. spool (order separately) <br />THQL21xx (20/40/60/80 A) <br />Q2xx (20/40/60/80 A) <br />Q24020CT2 (20/40 A) <br />±1% V nominal (±1.2V L-N and ±2.4V L-L) <br />24V, 1A <br />60 Hz/56-63 Hz <br />±0.1 Hz <br />160 A <br />200 A <br />200 A <br />80 A (IQ System Controller 3G only -SC200G111C240US 01) <br />2 x 80 A (la System Controller 3 -SC200D111C240US01), <br />1 x 80 A (IQ System Controller 3G -SC200G111C240US01 ) <br />(2) Factory installed quad breaker (Siemens or Eaton). NFT pre-wired to 40 A terminal of the quad breaker. <br />(3) Two units of CT-2OO-SPLIT or CT-2OO-CLAMP must be bought separately for generator integration. <br />(4) The IQ System Controller 3 is rated at 22 kAIC. <br />(5) Integrated hold-down kit support breakers (BR23O/BR23O/BR24O) without predrilled hole. <br />Integrated hold-down kit also supports GE/ABB and Siemens as mentioned under section alternate DER circuit breakers. <br />(6) "-" indicates alternating current (AC) supply. <br />(•) Power Control System. IQSC-3-DSH-OOO21-3.O-EN-US-2O23-O8-O8 <br />ELECTRICAL SPECIFICATIONS <br />Maximum overcurrent protection device rating for PV combiner unit 80 A <br />Internal busbar rating <br />Neutral-forming transformer (NFT) <br />MECHANICAL DATA <br />Dimensions (WxHxD) <br />Weight <br />Ambient temperature range <br />Cooling <br />Enclosure environmental rating <br />Maximum altitude <br />WIRE SIZES <br />Connections <br />(All lugs are rated to 90°C) <br />Neutral and ground bars <br />COMPLIANCE <br />Compliance (under progress) <br />WARRANTY <br />Limited warranty (restrictions apply) <br />COMPATIBILITY' <br />Battery <br />Microinverters <br />IQ Combiner <br />Communications Kit 2 <br />200 A <br />Breaker rating (pre-installed): 40 A between L1 and Neutral; 40 A between L2 and Neutral <br />Continuous rated power: 3,600 VA <br />Maximum continuous unbalance current: 30 A© 120 V <br />Peak unbalanced current: 80 A© 120 V for two seconds <br />50 cm x 91.6 cm x 24.6 cm (19.7 in x 36 in x 9.7 in) <br />39.4 kg (87 lbs) <br />-40°C to 50°C (-40°F to 122°F) <br />Natural convection and a heat shield <br />Outdoor, NEMA type 3R, polycarbonate construction <br />2500 meters (8200 feet) <br />Main lugs and backup load lugs <br />CSR breaker bottom wiring lugs <br />AC combiner lugs, IQ Battery lugs, and <br />generator lugs <br />Neutral (large lugs) <br />Large holes (5/16-24 UNF) <br />Small holes (10-32 UNF) <br />Cu/Al: 6 AWG-300 kcmil <br />Cu/Al: 2 AWG-300 kcmil <br />14 AWG-2 AWG <br />Cu/Al: 6 AWG-300 kcmil <br />14 AWG-1/0 AWG <br />14 AWG-6 AWG <br />UL 1741, UL 1741 SA, IEEE 1547:2018 (UL 1741-SB, 3rd Ed.), UL 1741 PCS CRD, Ull 998, UL 869A, UL <br />675, UL 5087, UL 50E' <br />CSA 22.2 No. 107.1, 47 CFR Part 15 Class B, ICES 003, ICC ES AC156. <br />The IQ System Controller 3/3G is approved for use as service equipment in the United States <br />Up to 10 years (EP200G-NA-02-RSD has a 5-year warranty) <br />IQ Battery 5P (IQBATTERY-5P-1P-NA) <br />108, 107, 106, and M Series Microinverters• <br />IQ Combiner 5/5C (X-IQ-AM1-240-5C, X-IQ-AMl-240-5) <br />COMMS-KIT-02 <br />(7) Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. <br />(8) For more details, refer to IQ System Controller 3/3G Quick Install Guide. <br />(9) M Series Microinverters can only be supported in states that have not yet adopted IEEE 1547:2018. <br />Enphase does not support mixing 108 Series Microinverters with other series on the same IQ Gateway. <br />IQSC-3-DSH-OOO21-3.O-EN-US-2O23-O8-O8 <br />929 E Jonquil Rd - <br />2018144011/27/2023