MODULE COMPATIBILITY
<br />Ecosolargy modules with 35, 40, and 50 mm frames
<br />Ecosola rgy ECOxxxYzzA-bbD
<br />Where "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D" can
<br />be blank or B
<br />ET Solar modules with 30, 35, 40, and 50 mm frames
<br />ET Solar ET-YZZZxx.xAA
<br />Where "Y" can be P, L, or M; "ZZZ" can be 660, 660BH, 672, 672BH, 754BH, 766BH, 772BH; and "AA" can
<br />be GL, TB, TW, WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC
<br />Flex modules with 35, 40, and 50 mm frames
<br />Flex FXS-xxxYY-ZZ;
<br />Where "YY" can be BB or BC; and "ZZ" can be MM1B, MM1W, MAB1W, SM1B, SM1W, SAC1B,
<br />SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, or SBC1W
<br />GCL modules with 35 mm and 40 mm frames
<br />GCL GCL-ab/YY xx.x
<br />Where "a" can be M or P; "b" can be 3 or 6; and "YY" can be 60, 72, 72H, or 72DH
<br />Gigawatt modules with 40 mm frames
<br />Gigawat t Solar GWxxxYY
<br />Where "YY" can be either PB or MB
<br />Hansol modules with 35 and 40 frames
<br />Hansol HSxxxYY-zz
<br />Where "YY" can be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AH2, AN1, AN3, AN4, HH2, HV1,
<br />orJH2
<br />Hanwha Solar modules with 40, 45, and 50 mm frames
<br />Hanwa Solar HSLaaP6-YY-1-xxxZ
<br />Where "aa" can be either 60 or 72; "YY" can be PA or PB; and "Z" can be blank or B
<br />Hanwha Q CELLS Modules with 32, 35, 40, and 42mm frames
<br />aaYY-ZZ-xxx
<br />where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK
<br />DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/
<br />TM, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1 /SC,
<br />G4.1/TM, G4.1/MAX, BFR G4.1/TM, BFR G4.1/MAX, BLK G4.1/TM, BLK G4.1/SC, EC-G4.4, G5, G5/
<br />Hanwha Q CELL SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6/SC, G6/TS,
<br />G6+/TS, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/
<br />SC, BLK-G6/TS, BLK-G6+/TS, BLK-G7, G7.2, GB, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3,
<br />L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, L-G8.3/BFG, L-G8.3/BGT, ML-G9, BLK ML-G9, ML-G9+, BLK
<br />ML-G9+, ML-G10, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-G10.a, BLK ML-G10.a, ML-G10.a+, BLK
<br />ML-G10.a+, XL-G9, XL-G9.2, XL-G9.3, XL-G9.3/BFG, XL-G10.2, XL-G10.3, XL-G10.c, XL-G10.d, XL-G10.d/
<br />BFG or XL-G10.3/BFG
<br />Heliene modules with 40 mm frames
<br />Heliene YYZZXXXA
<br />Where "YY" can be 36, 60, 72, 96, 120 or 144; "ZZ" can be HC, M, P, or MBLK; and "A" can be blank,
<br />HomePV, or Bifacial
<br />HT-SME modules with 35 and 40 mm frames
<br />HT-SME HTyy-aaaZ-xxx
<br />Where "yy" can be 60, 66, 72 or 78, "aaa" can be 18, 156 or 166, "Z" can be M, P, M-C, P-C, M(S), M(VS),
<br />M(V), P(V), M(V)-C, P(V)-C, or X
<br />Hyundai modules with 33, 35, 40 and 50 mm frames
<br />Hyundai HiY-Sxxx.ZZ
<br />Where "Y" can be A, D or S; "S" can be M or S; and "ZZ" can be GI, HG, HI, Kl, Ml, MF, MG, Pl, Rl,RG,
<br />RG(BF), RG(BK), SG, Tl or TG
<br />Itek Modules with 40 and 50 mm frames
<br />Itek IT-xxx-YY
<br />Where "YY" can be blank, HE, or SE, or SE72
<br />© 2021 IRON RIDGE, INC. VERSION 3.3 FLUSH MOUNT INSTALLATION MANUAL -22
<br />lntertek 8431 Murphy Drive
<br />Middleton, WI 53562 USA
<br />Telephone: 608.836.4400
<br />Facsimile: 608.831.9279
<br />www.intertek.com
<br />Test Verification of Conformity
<br />In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of
<br />the referenced specifications at the time the tests were carried out.
<br />Applicant Name & Address:
<br />Product Description:
<br />Ratings & Principle
<br />Characteristics:
<br />Models:
<br />Brand Name:
<br />Relevant Standards:
<br />Verification Issuing Office:
<br />Date of Tests:
<br />Test Report Number(s):
<br />lronRidge, Inc.
<br />28357 Industrial Blvd
<br />Hayward, CA 94545
<br />USA
<br />Flush Mount System with XR Rails.
<br />Fire Class Resistance Rating:
<br />-Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1,
<br />2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope
<br />applications with Typel, 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance
<br />between the bottom the module frame and the roof covering), per the standard this system can
<br />be installed at any gap allowed by the manufacturers installation instructions. No perimeter
<br />guarding is required. This rating is applicable with any Iron Ridge or 3'rd party roof anchor.
<br />lronRidge Flush Mount with XR Rails
<br />lronRidge Flush Mount
<br />UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices,
<br />Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules
<br />and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18,
<br />2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels.
<br />lntertek Testing Services NA, Inc.
<br />8431 Murphy Drive
<br />Middleton, WI 53562
<br />08/27/2014 to 03/17/2015
<br />101769343MID-001rl, 101769343MID-001a, 101915978MID-001 & 101999492MID-001arl-crl,
<br />104428358MID-001 EEV
<br />Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address.
<br />This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically
<br />imply product certification.
<br />Completed by: Ch ris Zimbrich
<br />Title: Technician I, Fire Resistance
<br />Signature:
<br />Date: 08/27/2020
<br />Reviewed by: Chad Naggs
<br />Title: Technical Team Lead, Fire Resistance
<br />Signature:
<br />Date: 08/27/2020
<br />This Verification is far the exclusive use of lntertek's client and is provided pursuant ta the agreement between lntertek and its Client. lntertek's responsibility and liability are
<br />limited to the terms and conditions of the agreement. lntertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense
<br />or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the lntertek name or ane af its
<br />marks for the sale or advertisement of the tested material, product or service must first be approved in writing by lntertek. The observations and test/inspection results
<br />referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been
<br />under an lntertek certification program.
<br />GFT-OP-11a (24-MAR-2014)
<br />929 E Jonquil Rd -
<br />2018144011/27/2023
|