ELECTRICAL NOTES per 2022 California Electrical Code <br />A. PANEL LOCATIONS <br />B. NON-METTALIC SHEATED CABLE (CEC 334) <br />C. CIRCUITS AND RECEPTACLES <br />D. LIGHTING (CEC 210.70) <br />E. FANS <br />F. SMOKE ALARMS <br />LIGHTING NOTES: <br />NOTES: <br />BATHROOM EXCHAUST FANS SEC.4.506.4 MECHANICAL EXCHAUST FANS WHICH EXCHAUST <br />DIRECTLY FROM BATHROOM SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE <br />LATION SYSTEM. <br />COVERS WHICH CLOSE WHEN THE FAN IS OFF THAT HAVE A MIN. INSULATION VALUE OF R-4.2 <br />THE BUILDING, AND CONTROLLED BY A READILY ACCESSIBLE HUMIDSTAT OR A WHOLE HOUSE VENTIL <br />WHOLE HOUSE EXCHAUST FANS SEC.4.507.1 WHOLE HOUSE FANS SHALL HAVE INSULATED LOUVERS OR <br />HEATING AND AIR CONDITIONING DESIGN SEC.4.507.2 SYSTEM SHALL BE SIZED,DESIGNED AND <br />SPECIFIED ACCORDING TO ACCA,ASHRAE,OR EQUIVALENT DESIGN SOFTWARE OR METHODS. <br />1. ALL (E) DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL (E) DIMEN SIONS IN FIELD. <br />5. LOCATION OF SMOKE DETECTORS (310.9.1) IN EACH SLEEPING AREA SHALL BE CENTRALLY LOCATED IN CORRIDOR (OR AREA) LEADING TO SLEEPING <br />AREAS. SMOKE DETECTOR SHALL SOUND AN ALARM IN ALL SLEEPING AREAS. <br />2. ALL EXTERIOR WINDOWS SHALL UTILIZE MULTIPLE GLAZED PANELS CONSISTING OF NOT LESS THAN DUAL PANE GLAZING. <br />3. WINDOWS FOR EMERGENCY EGRESS OR RESCUE, SHALL BE OPERABLE FROM THE INSIDE TO PROVIDE A CLEAR OPENING OF 5.7 SQ.FT. MINIMUM. NET CLEAR OPENING WIDTH <br />DIMENSION SHALL BE 20" AND 24" MINIMUM IN HEIGHT.SILL FINISHED HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR LEVEL. <br />6. ALL GENERAL LIGHT AT KITCHEN AND BATH SHALL BE AN EFFICIENT LIGHTING. <br />2. SHOWERS AND TUB-SHOWERS COMBINATION SHALL BE PROVIDED WITH SEPERATE CONTROL VALVES FOR PRESSURE BALANCE.THE THERMO STATIC MIXING VALVE SHALL BE <br />TYPE U.P.C. 420. <br />3. PLUMBING FIXTURES WITH THE FOLLOWING MAXIMUM WATER USAGE'S SHALL BE INSTALLED IN THE ADDITION,WHERE APPLICABLE,AND IN EXISTING BATHS WASHROOMS, <br />KITCHENS, LAUNDRY,ETC,,, <br />a) WATER SAVING SHOWERHEADS SHALL HAVE A MAXIMUM FLOW OF 1.8 GAL PER MIN. AT 80 PSI. (CPC 408.2) <br />b) WATER SAVING SINK AND LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW OF 1.5 GALLONS PER MIN.AT 60 PSI. <br />c) WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. <br />d) KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI. <br />WARM AIR FURNACES ARE PROHIBITED IN BED ROOMS OR BATHROOMS UNLESS THEY ARE PROTECT VENT HEATER. <br />12. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED.91.2406.4: <br />A. INGRESS AND EGRESS DOORS <br />B. PANELS IN SLIDING OR SWINGING DOORS <br />C. DOORS AND ENCLOSURE FOR HOT TUB, BATH TUB SHOWERS (ALSO GLAZING IN WALL ENCLO SING THESE COMPARTMENTS WITHIN 5' OF STANDING SURFACE) <br />D. IF WITHIN 2' OF VERTICAL EDGE OF CLOSED DOOR AND WITHIN 5' OF STANDING SURFACE. <br />E. IN WALL ENCLOSING STAIRWAY LANDING <br />F. GUARDS AND HANDRAILS. <br />8. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLD WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (R401.3) <br />9. VEHICULAR ACCESS DOORS SHALL COMPLY WITH SECTION (R612.4). <br />11. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY <br />DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT,PRESERVATIVE AND END USE. PRESERVATIVES <br />SHALL BE LISTED IN SECTION 4 OF AWPA U1. <br />12 PROVIDE ANTI GRAFFITI FINISH WITHIN THE FIRST 9 FEET ,MEASURED FROM THE GRADE,AT EXTERIOR WALLS AND DOORS EXCEPTION: MAINTENANCE OF BUILDING <br />AFFIDAVIT IS RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGE LES TO REMOVE ANY GRAFFITI WITHIN 7-DAYS OF THE GRAFFITI BEING <br />APPLIED (6306). <br />3. SHOWER AND TUB ENCLOSURES SHALL BE TEM PERED (CBC 2406.4) WINDOWS AT SHOWERS AND TUBS SHALL BE TEMPERED. USE WATERPROOF 70" HIGH SHOWER WALL WITH <br />HIGH ABSORBENT FINISH (CBC 80.1.3)FLOORS AND WALLS IN WATER CLOSET COMPARTMENTS AND SHOWERS SHALL COMPLY WITH SECTION 807.1.1 THROUGH 807. 1.4 AND 807.2. <br />A. FIXED AND OPERSBLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOORS ASSEMBLIES. <br />B. GLAZING IN A INDIVDUAL FIXED OROPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" INCH ARC OR EITHER VERTICAL EDGE OF THE <br />DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. <br />D. GLAZING IN RAILINGS. <br />E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS.WHIRPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE <br />OF THE GLAZING IS LESS 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING. <br />Panels shall not be located in the vicinity of easily ignitable material, such as clothes, or in bathroom ( CEC 240-24(D) ). <br />1.Protected by rigid metal conduit,intermediate metal conduit,electrical metallic tubing,schedule 80 PVC Conduit, pipe,or other means when cable is exposed <br />or subject to physical damage. (CEC 334.15(b) ). <br />2.Protected by a 1/16 inch steel plate or sleeve,or be not less than 1-1/4 inch fromthe nearest edge of the framing member,When installed through framing members. <br />Steel plates or sleeves are required on all double shear walls when cable is installed either through or parrallel to framing members (CEC 334.17 ). <br />3.Protected by guard strip with 6 feet of attic when no permanent stairs or ladders are provided (CEC 334.23, 320.23). <br />4.Protected by guard strips in entire attic when permanent stairs or ladders are provided. Access panels or doors from the second floor into the attic are cinsidered <br />permanent access and guard strips are required in the entire attic. <br />5.Have a bending raduis not less than 5 times the diameter of the cable (CEC 334.24) ). <br />6.Supported at intervals not exceeding 4 1/2 feet and within 12" of every outlet box,cabinet or fitting (CEC 334.30) . <br />1.Receptacles shall be installed so that no point along the floor line in any wall space is more than 6ft. from an outlet,including any wall space 2 ft.wide or greater. Note: A <br />fixed panel of a sliding glass door is considered wall space. (CEC 210.52(A) ). <br />2.In kitchens,breakfast rooms,pantries,and dining rooms a minimum of 2-20A circuits shall be provided (CEC 210.11(c)(1) ). Counter space receptacles shall be <br />GFCI (CEC210.8(A) ). and installed: <br />At each wall counter space that is 12 in or greater (CEC 210.52(C)(1) ); <br />No more than 48 in oc. (CEC 210.52(C)(1); <br />Maximum 24 in from the end of the counter (CEC 210.52(C)(1) ). <br />Maximum 20 in above counter surface (CEC 210.52(C)(5) ). <br />On island counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC <br />210.52.11(C)(5) EXCEPTION). An island with less than 12'" behind the range top of sink is con sidered as dividing the <br />countertop into two seperate spaces (CEC210.52(C)(2) ). <br />On peninsular counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC 210.52(C)(5) <br />Exception). <br />3.Bathroom shall have a seperate 20A circuit (CEC210.11(C)(3) with at least one GFCI wall receptacle within 36 in of each basin (CEC 210.8(A)(1); (CEC <br />210.52(D). <br />4.Laundry rooms shall have a seperate 20A circuit with at least one receptacle shall be provided (CEC 210.11(C)(2) ).All receptacles within 6 ft. of the sinkshall be GFC I <br />(CEC 210.8.(A)(7) ). <br />5.In garages,at least one GFCI receptacle shall be provided (CEC210.52.(G) ). All other garage recep tacle except those dedicated to an appliance or that are not accessible <br />shall be GFCI.(CEC 210.8(A)(2). <br />6.In hallway of 10 ft or more in length at least one receptacle shall be provided ( CEC 210.52(H) ). <br />7.Outdoor outlets shall be GFCI (CEC 210.8(3) ).One outlet shall be installed at the front of the dwelling and one at the rear of the dwelling.Receptacles shall be accessible at grade <br />level and not more than 6 1/2 ft above grade (CEC 210.52(E) ). <br />8.All crawl space receptacle shall be GFCI (CEC 210.8(A)(4) ). <br />9.All unfinished basement receptacles shall be GFCI unless they are not readily accessible or are service a dedicated appliances (CEC 210.8(A)(5) ). <br />10.All receptacles with 6 ft of a wet bar shall be GFCI (CEC 210.8(A)(7) ). <br />11. All receptacles on 15A or 20A branch circuits that supply family rooms,dining rooms,living rooms,parlors, libraries,dens,bedrooms,sunrooms,recreation rooms,closets, hallways, or <br />similar rooms,or areas shall beprotected by combination-type Arc-fault Circuit Interrupters (AFCI),including switched outlets(CEC 210.12(B) ). <br />12.All receptacles serving appliances or motors with a rating of 1 HP or 6 amps shall be on a seperate circuits. <br />13.For HVAC equipment,a seperate 15A or 20A circuit with an accessible receptacle at the equipment shall be provided within 25 ft of the equipment (CEC 210.63).If located in an <br />under floor area.The receptacle shall be GFCI (CEC 210.8(4) ). <br />1.Switched lighting shall be installed in: from an outlet,including any wall space 2 ft.wide or greater. Note: A fixed panel of a sliding glass door <br />All habitable rooms, Bathrooms,Hallways,and Stairways at each level. <br />Garages <br />At all outdoor entrances and exits. <br />In all attics, under floor areas,utility rooms,and basement used for storage. <br />Near HVAC equipment in attic,under floor areas,rooms or basements,with a <br />switch at the access point. <br />2.Lighting installed in a closet shall be a surface mounted or recessed flourescent fixture or a surface mounted incandescent fixture with completely enclosed <br />lamps.surface incandescent lighting shall be installed a minimum of 12 in. from the nearest point of a storage space. Surface fluorescent lighting and recessed <br />lighting shall be installed a minimum of 6 in. from the nearest point of a storage space (CEC 410.8(D). <br />In bathrooms containing tubs or showers,a fan capable of exhausting 50 cfm shall be installed (Energy Standards 150 (0). <br />In new construction,smoke alarms shall recieve their primary power from the building wiring.The wiring shall be permanent and installed without a disconnecting <br />switch other than those required for over current protection (CRC R314.4). <br />2. BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS MUST HAVE HIGH EFFICACY LIGHTING,OR AN OCCUPANT SENSOR WITH A MANUAL-ON/OFF <br />FEATURE MAY BE INSTALLED. <br />3. BEDROOMS,LIVING ROOMS,FAMILY ROOMS,AND OTHER ROOMS USED FOR LIVING AND SLEEPING MUST HAVE HIGH EFFICACY LIGHTING,OR AN <br />OCCUPANT SENSOR WITH A MANUAL -ON/OFF FEATURE OR DIMMER MAY BE INSTALLED. <br />4. EXTERIOR LIGHTING MUST BE HIGH EFFICACY OR AN OCCUPANT SENSOR WITH AN INTEGRAL PHOTO CONTROL MAY BE INSTALLED. <br />1. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATE SPECIFIED IN SECTION 4.303.1 <br />2. WHEN THE SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, AND/OR OTHER OUTLETS CONTROLLED BU A SINGLE VALVE SHALL NOT EXCEED 2.0 <br />GALLONS PER MINUTE AT 80 PSI, THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE OPERATED AT A TIME. <br />ROOF NOTES: <br />ARCHITECTURAL PLAN NOTES: <br />1. KITCHEN RANGE HOODS SHALL BE INSTALLED FOR COOKING FACILITIES WITH AN APPROVED FORCED-DRAFT SYSTEM OF VENTILATION <br />VENTED TO THE OUTSIDE OF THE BUILDING. DUCTS USED FOR DOMESTIC KITCHEN RANGE VENTILATION SHALL BE OF METAL, OR OTHER <br />APPROVED MATERIAL, AND SHALL HAVE SMOOTH INTERIOR SURFACES. DUCTS FOR DOMESTIC RANGE HOODS SHALL ONLY SERVE COOKING <br />APPLIANCES. (CMC 504.3; 3:& 150.0 (o) 1G, 2B) <br />KITCHEN NOTES: <br />4. ELEMENTS SHOWN ON THIS PLAN ARE NEW UNLESS LABELED AS EXISTING "(E)" OR SHOWN ON THE EXISTING FLOOR PLAN. <br />7. DOORS AND WINDOWS SHALL BE CENTERED ON WALLS AS SHOWN, UNLESS SPECIFICALLY DIMENSIONED. <br />BATHROOM NOTES: <br />1. BATHROOMS SHALL BE PROVIDED WITH MECHANICAL VENTILATION OF 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS. <br />4. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS W ITH A SHOWERHEAD, AND SHOWER COMPARTIMENTS SHALL BE FINISHED <br />WITH A NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. <br />5. ACCESS TO BATHROOM FIXTURES: WATER CLOSETS SHALL BE SET AT LEAST 15" FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. <br />THE CLEAR SPACE IN FRONT OF ANY WATER CLOSET SHALL BE NOT LESS THAN 24". <br />9. SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQ. IN. AND SHALL BE CAPABLE OF <br />ENCOMPASSING A 30" CIRCLE. <br />7. SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION IN ACORDANCE <br />WITH ASSE 1016 OR ASME A112.18.1/SCA B125.1. (CPC. 408.3) <br />e) INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORADNCE WITH CPC SECTION 609.11.1 ANS SECTION 609.11.2 <br />5. EXTERIOR LANDING OR FLOOR AT EXTERIOR DOORS SHALL BE A MAXIMUM OF 7-3/4" BELOW THE TOP THRESHOLD THE THE DOOR DOES <br />NOT SWING OUT OVER THE LANDING OR FLOOR. IF DOOR SW INGS OUTWARD, A LANDING SHALL BE 1.5" MAXIMUM BELOW THE TOP OF <br />THRESHOLD. LANDINGS AT DOORS SHALL HAVE A LENGTH MEASURED IN DIRECTION OF TRAVEL NOT LESS THAN 36". LANDINGS SHALL <br />SLOPE AWAY FROM THE DWELLING AT 2% MAXIMUM (SLOPE.11.3) <br />SAFETY GLAZING IS REQUIRED IN THE FOLLOWING LOCATIONS: <br />6. SHOWER CONTROL - CONTROL VALVES AND SHOWERHEADS SHALL BE LOCATED ON THE SIDE OF SHOWER COMPARTMENTS OR <br />OTHERWISE ARRANGED SO THAT THE SHOWERHEAD DOES NOT DISCHARGE DIRECTLY AT THE ENTRANCE OF THE COMPARTMENT <br />SO THAT THE BATHER CAN ADJUST THE VALVES PRIOR TO STEPPING INTO THE SHOWER SPRAY (CPC 408.9) <br />8. SHOWER THRESHOLD SHALL BE NO LESS THAN 2" ABOVE THE SHOWER DRAIN. THE FINISHED FLOOR OF THE RECEPTOR SHALL <br />SLOPE UNIFORMLY FROM THE SIDES TOWARDS THE DRAIN NO LESS THAN1/4"" PER FOOT AND NO MORE THAN 1/2" PER FOOT <br />(CPC408.5) <br />10. BATHROOM AND EXHAUST FAN(S) SHALL BE OF THE FALLOWING. <br />a. ENERGY STAR COMPLIANT <br />b. BE DUCTED TO TERMINATE OUTSIDE THE BUILDING <br />c. BE RATED FOR SOUND AT A MAXIMUM OF 3 ZONE <br />d. SWITCHED SEPARATELY FROM LIGHTING. <br />a. KITCHEN VENTED RANGE HOOD. <br />i HERS VERIFICATION OF AIRFLOW AND SOUND RATING <br />ii MINIMUM AIRFLOW OF 100 CFM <br />iii MAXIMUM ZONE RATING. OF 3.0 <br />C. GLAZING IN AN INDIVUAL FIXED OR OPERABLE PANEL THAT MEET ALL OF THE FOLLOWING CONDITIONS: <br />1) EXPOSED AREA OF AN INDIVUAL PANE GREATER THAN 9 SQUARE FEET. <br />2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR <br />3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR <br />4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. <br />A MINIMUM OF 50% OF THE LUMINARIES IN A KITCHEN MUST BE HIGH EFFICACY. <br />PLUMBING NOTES: <br />13. EMERGENCY ESCAPE AND RESCUE OPENINGS: BASEMENTS, HABITABLE ATTICS, AND EVERY SLEEPING ROOM SHALL BE PROVIDED WITH AN <br />OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. THE BOTTOM OF THE CLEAR OPENING SHALL NOT BE MORE THAN 44" ABOVE THE <br />FLOOR. OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. WHEN LOCATED AT THE <br />GRADE FLOOR, THE NET CLEAR OPENING SHALL BE AT LEAST 5 SQ. FT. ELSEWHERE, THE NET CLEAR OPENING SHALL BE AT LEAST 5.7 SQ. FT. <br />THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24". THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20". OPENINGS SHALL BE <br />OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. BARS, GRILLES, COVERS, <br />SCREENS OR SIMILAR DEVICES ARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS, PROVIDED THE MINIMUM <br />NET CLEAR OPENING SIZE COMPLIES AS DESCRIBED ABOVE. SUCH DEVICES SHALL BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT <br />THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR FORCE GREATER THAN THAT WHICH IS REQUIRED FOR NORMAL OPERATION OF THE ESCAPE <br />AND RESCUE OPENING. SECURITY BARS (BURGLAR BARS) SHALL COMPLY WITH CALIFORNIA REFERENCED STANDARDS CODE (TITLE 24, PART 12) <br />CHAPTER 12-3. <br />14. WINDOW SILLS, FALL PROTECTION: WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72" ABOVE THE FINISHED <br />GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24" ABOVE THE FINISHED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OTHERWISE, OPENINGS SHALL NOT ALLOW THE PASSAGE OF A 4" DIAMETER <br />SPHERE, OR A CODE-COMPLIANT FALL PREVENTION OR OPENING LIMITING DEVICE SHALL BE PROVIDED. <br />15. ATTIC ACCESS: AN ATTIC ACCESS SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. 30" MINIMUM <br />HEADROOM IS REQUIRED ABOVE THE ACCESS OPENING. THE ROUGH-FRAMED OPENING SHALL BE AT LEAST 22" x 30". WHEN EQUIPMENT IS <br />LOCATED IN THE ATTIC, THE ACCESS OPENING SHALL BE AT LEAST AS LARGE AS THE LARGEST COMPONENT OF THE EQUIPMENT. <br />16. WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH <br />SMOKE ALARMS AND CARBON MONOXIDE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. (CRC R314.2.2 & R315.2.1) SMOKE ALARMS <br />SHALL BE PROVIDED IN EACH BEDROOM, OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R314.3) CARBON <br />MONOXIDE ALARMS SHALL BE PROVIDED OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R315.3) ALL <br />SMOKE DETECTORS 10 YEARS OR OLDER SHALL BE REPLACED. <br />1. RECESSED DOWNLIGHT LUMINAIRES IN CEILING . IN ADDITION TO COMPLYING WITH 150.0 (k) LUMINAIRIES RECESSED INTO CEILINGS SHALL MEET ALL OF <br />OF THE FALLIWING REQUIREMENTS. <br />a. BE LISTED, AS DEFINED IN SECTION 100.0, FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY <br />RECOGNIZED TESTING/RATING LABORATORY: AND <br />b. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH <br />ASTM E283. AN EXHAUST FAN HOUSING SAHALL NOT BE REQUIERD TO BE CERTIFIED AIRTIGHT: AND <br />c. BE SEALED WITH A GASKET OR KAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND <br />UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK: AND <br />d. SHALL NOT CONTAIN SCREW BASE SOCKETS. <br />6. THE MINIMUM WIDTH OF HALLWAYS SHALL BE AT LEAST 3 FT. <br />1. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS. <br />2. GLAZING IN A FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF THE DOOR <br />IN A CLOSED POSITION, AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE WALKING SURFACE. <br />3. GLAZING IN A FIXED OR OPERABLE PANEL MEETING ALL OF THE FOLLOWING CONDITIONS: THE EXPOSED AREA OF AN INDIVIDUAL PANE IS <br />LARGER THAN 9 SQ. FT.; AND THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18" ABOVE THE FLOOR; AND THE TOP EDGE OF THE GLAZING <br />IS MORE THAN 36" ABOVE THE FLOOR; AND A WALKING SURFACE IS WITHIN 36" OF THE GLAZING. <br />4. ALL GLAZING IN RAILINGS. <br />5. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE <br />THE BOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />6. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF <br />THE GLAZING IS LESS THAN 60" ABOVE A WALKING SURFACE AND WITHIN 60" OF THE WATER'S EDGE. <br />9. SAFETY GLAZING SHALL BE PROVIDED WITH A MANUFACTURER'S DESIGNATION OR LABEL AS REQUIRED BY THE CODE. <br />10. SAFETY GLAZING REQUIRED TO BE PERMANENTLY MARKED (ETCHED) AS REQUIRED BY CRC R.308.1. <br />8. GLAZING ADJACENT TO STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE <br />EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD. <br />7. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE <br />OF THE GLAZING IS LESS THAN 60" ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. <br />11. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING COMFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS) <br />(R308.4). <br />1. ROOF ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE CODE AND THE APPROVED MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS SUCH THAT THE ROOF ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. FLASHINGS SHALL BE <br />INSTALLED IN A MANNER THAT PREVENTS M0ISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH <br />M0ISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. <br />2. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE PROVIDED BY <br />VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL BE SCREENED WITH A <br />CORROSION-RESISTANT MESH HAVING 1/16" - 1/8" OPENINGS. <br />3. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 /150 OF THE AREA OF THE SPACE VENTILATED. REDUCTION TO <br />1/300 IS PERMITTED IF BETWEEN 50% AND 80% OF THE VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION <br />OF THE SPACE, AT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS. AS BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE <br />CEILING. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF 1" <br />SPACE SHALL BE PROVIDED BETWEEN ll-lE INSULATION AND THE ROOFSHEATHING AND AT THE LOCATION OF THE VENT. <br />4. AN ALTERNATIVE, THE NET FREE CROSS-VENTILATING AREA MAY BE REDUCED TO 1/300 WHEN A CLASS I OR II VAPOR <br />IN BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS AND WALK-IN CLOSETS, AT LEAST ONE INSTALLED LUMINAIRE SHALL BE CONTROLLED BY AN <br />OCCUPANCY OR VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. <br />AFOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE <br />SAME LOT SHALL MEET THE REQUIREMENT IN ITEM I AND THE REQUIREMENTS IN EITHER ITEM II OR ITEM III: I. CONTROLLED BY A MANUAL ON AND OFF <br />CONTROL SWITCH THAT PERMITS THE AUTOMATIC ACTIONS OF ITEMS II OR III BELOW; AND II. CONTROLLED BY A PHOTOCELL AND EITHER A MOTION SENSOR <br />OR AN AUTOMATIC TIME SWITCH CONTROL; OR III. CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL. CONTROLS THAT OVERRIDE TO ON SHALL NOT <br />BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY RETURNS THE AUTOMATIC CONTROL TO ITS NORMAL OPERATION WITHIN 6 HOURS. AN ENERGY <br />MANAGEMENT CONTROL SYSTEM THAT PROVIDES THE SPECIFIED LIGHTING CONTROL FUNCTIONALITY AND COMPLIES WITH ALL REQUIREMENTS APPLICABLE <br />TO THE SPECIFIED CONTROLS MAY BE USED TO MEET THESE REQUIREMENTS. <br /> HIGH EFFICACY LUMINARIES MUST BE PIN BASED. <br /> RECEPTACLES IN ALL ROOMS SHALL BE AFCI PROTECTED. <br /> ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLE PER CEC 406.11. <br /> RECESSED LIGHT FIXTURES INSTALLED IN A RATED CEILING SHALL BE RATED(IC), <br />(AT) AIR TIGHT, AND GASKETED OR CAULKED BETWEEN THE HOUSING AND CEILING. <br />LIGHTING CONTROLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 110.9. <br />Project number <br />Date <br />Drawn by <br />Checked by <br />E-mail:skyaaconstruction@gmail.com <br />THIS DESIGN AND DRAWINGS, ARE <br />COPYRIGHT PROTECTED AND ARE <br />THE EXCLUSIVE PROPERTY OF AA SKY <br />CONSTRUCTION INC., THEY SHALL BE <br />NO USED, MODIFIED DUPLICATED IN <br />WHOLE OR IN ANY MANNER, NOR <br />ASSIGNED TO A THIRD PARTY WITHOUT <br />THE WRITTEN AUTHORIZATION <br />OF AA SKY CONSTRUCTION INC. <br />APPROVAL STAMP <br />OWNER <br />CONTACT PERSON <br />DESIGNER <br />AA SKY CONSTRUCTION INC. <br />2074 SILVERADO ST. <br />SAN MARCOS CA 92078 <br />LIC#1061749 <br />OFFICE 858 888 3752 <br />CELL 760 845 7697 <br />RAFAEL G LUJANO <br />E-MAIL: SKYAACONSTRUCTION@GMAIL.COM <br />CONSULTANTS <br />05-E-01 <br />GENERAL NOTES <br />0001 <br />940 E ANAHURST PL. <br />STA. ANA, CA 92707 <br />05-20-2024 <br />Lucas <br />- <br />EX. 400 SQ.FT. <br />GARAGE+ NEW 280 <br />SQ.FT. TO BE A 680 <br />SQ.FT. ADU <br />RAFAEL LUJANO <br />RAFAEL LUJANO <br />2201 HALLADAY ST. STA. ANA, CA 92707 <br />skyaaconstruction@gmail.com <br />+17608457697 <br />No. Description Date <br />1 Revisión 1 Fecha 1 <br />1.2 GALLONS PER MIN. AT 60 PSI. <br />940 E Anahurst Pl & 2201 <br />S Halladay11/25/2024