My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
939 W Fairbrook Ln - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairbrook Ln
>
939 W Fairbrook Ln
>
939 W Fairbrook Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:22 PM
Creation date
6/1/2025 12:11:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20180285
101115827
Full Address
939 W Fairbrook Ln
Document Relationships
101115827 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fairbrook Ln\939 W Fairbrook Ln
20180285 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fairbrook Ln\939 W Fairbrook Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SUNPOWER CORPORATION Document #524734 Rev G <br />SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 <br />Document #524734 Rev G, Vol. 2 1 SunPower Proprietary <br />InvisiMount Span Tables <br />Engineering Summary Letter <br />VVolume: 2 <br />ASCE 7 Version: 7-16 <br />Module Type: 22 Sq. Ft. Module <br />Roof Attachment: Composite Shingle <br />High Wind: No <br />High Snow: No <br />The Span Tables are divided into two Parts: <br />x Part 1: Simplified Tables (Wind Tunnel Loads) <br />x Part 2: General Tables (ASCE 7 Analytical Method) <br />Part 1 features spans based on forces on the InvisiMount system using exposure coefficients, GCp, <br />provided by a Wind Tunnel Test Report by Cermak, Petrka, & Petersen (CPP). These values provide a <br />more accurate and economical solution but apply to less configurations. It is recommended to use these <br />values whenever possible, and when not, to use the spans provided in Part 2. <br />Approved Attachments: <br />The following span tables are adequate for the following roof attachments: <br />x SunPower InvisiMount L-Foot attachment <br />x Pegasus Composite Shingle Roof Attachment <br />o And roof attachments with capacities equal to or greater than all of the following Load <br />and Resistance Factor Design (LRFD) values: <br /> Tension 1000lb <br /> Compression 1000lb <br /> Shear 390lb <br />Scope: <br />x Module orientations: Portrait & Landscape <br />x Gable and Hip roofs only with modules not in the overhang sections of the roof <br />x Roof heights <br />o 30ft (Part 1 only) <br />o 20-60ft (Part 2 only) <br />x Roof Slope <br />o 4:12 to 8:12 (Part 1 only) <br />o 2:12 to 12:12 (Part 2 only) <br />x Exposures Categories B, C, D <br />x Basic Wind Speeds: <br />o ASCE 7-10: 110-140mph High Wind: 145-180mph <br />o ASCE 7-16: 90-130mph High Wind: 135-180mph <br />x Ground Snow Loads: <br />o 0-60psf (10psf increments) <br />o High Snow Volumes: 80-200psf (20psf increments) <br />o High Wind Volumes: 0psf <br />939 W <br />Ln07/19/23
The URL can be used to link to this page
Your browser does not support the video tag.