My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
941 W Alton Ave - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Alton Ave
>
941 W Alton Ave
>
941 W Alton Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:21 PM
Creation date
6/1/2025 12:11:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20179669
101115123
Full Address
941 W Alton Ave
Document Relationships
101115123 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alton Ave\941 W Alton Ave
20179669 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Alton Ave\941 W Alton Ave
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:11 PM
Modified:
5/30/2025 5:09 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV-1.0 <br />REVISIONS <br />DOC ID: <br />PROJECT <br />SUMMARY <br />GR <br />I <br />D <br />- <br />T <br />IE <br />D <br /> <br />S <br />O <br />L <br />A <br />R <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br />S <br />Y <br />ST <br />EM <br />SSPR-013 <br />94 <br />1 <br /> <br />W <br />E <br />S <br />T <br /> A <br />L <br />T <br />ON <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />, <br />DATE: 03/22/23 <br />CONTRACTOR: PAUL NAKHLE <br />COMPANY: SOLECTRIC SOLUTION <br />SA <br />N <br />T <br />A <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />SW1 - DISCONNECT <br />POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) <br />! CAUTION ! <br />CEC 690.56(C)(1)(a) AND CFC1204.5.1, 1204.5.1 <br />! WARNING ! <br />CEC 690.13(B) <br />INSTALLED BY SOLECTRIC SOLUTION <br />AC SOLAR DISCONNECT (SW1) AC DISCONNECT (SW1) <br />PV SYSTEM DISCONNECT <br />CEC 690.13(B) <br />MAXIMUM AC OPERATING CURRENT: 58.2A <br />MAXIMUM AC OPERATING VOLTAGE: 240V <br />CEC 690.54 <br />! WARNING ! <br />CEC 705.12(B)(3) <br />4 <br />5 6 <br />8 <br />5 6 <br />4 <br />2 <br />TURN RAPID <br />SHUTDOWN SWITCH <br />TO THE 'OFF' <br />POSITION TO SHUT <br />DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD IN <br />THE ARRAY. <br />SOLAR BREAKER (MSP) <br />CEC 705.12(B)(2)(3)(B) <br />MSP - MAIN SERVICE PANEL <br />DC RACEWAYS <br />1 <br />3 <br />7 <br />LABELING NOTES <br />1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2019 CEC AND 2019 <br />CFC WILL BE INSTALLED AS REQUIRED <br />2 <br />LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI <br />Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND <br />CAUTION SIGNS USED THE STANDARD HEADER COLORS, <br />HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. <br />THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST <br />50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH <br />CEC 110.21(B). <br />3 <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED <br />PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING <br />MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING <br />MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH <br />CEC 690.56(B). <br />4 <br />LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO <br />THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 <br />FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL <br />UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF <br />3/8” IN BLACK ON A YELLOW BACKGROUND, AND REMAINING <br />TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16” <br />IN BLACK ON WHITE BACKGROUND <br />5 <br />LABEL(S) WITH MARKING, "WARNING PHOTOVOLTAIC POWER <br />SOURCE," SHALL BE LOCATED AT EVERY 10 FEET OF EACH DC <br />RACEWAY AND WITHIN ONE FOOT OF EVERY TURN OR BEND <br />AND WITHIN ONE FOOD OF EVERY TURN OR BEND AND WITHIN <br />ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF <br />ROOF/CEILNG ASSEMBLIES, WALLS AND BARRIERS. THE LABEL <br />SHALL HAVE 3/8" TALL LETTERS AND BE REFLECTIVE WITH <br />WHITE TEXT ON A RED BACKGROUND <br />MULTIPLE SOURCES OF POWER <br />ELECTRIC SHOCK HAZARD. TERMINALS ON <br />BOTH LINE AND LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN POSITION <br />DUAL POWER SOURCE, SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM. <br />ANY AC ELECTRICAL PANEL THAT IS FED BY <br />BOTH THE UTILITY AND THE PHOTOVOLTAIC <br />SYSTEM (MSP) <br />EACH DISCONNECTING MEANS FOR <br />PHOTOVOLTAIC EQUIPMENT (SW1,I1) <br />PHOTOVOLTAIC SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />2 7 8 <br />SOLAR ELECTRIC <br />PV PANELS <br />SEE NOTE NO. 5 (DC RACEWAYS) <br />WARNING <br />CEC 690.31(G)(3) <br />3 <br />PHOTOVOLTAIC POWER SOURCE <br />! WARNING ! <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE. <br />1 SEE NOTE NO. 4 (MSP) <br />941 W Alton Ave - <br />2017966906/27/23
The URL can be used to link to this page
Your browser does not support the video tag.