Laserfiche WebLink
MSP <br />UM <br />LC <br />JB <br />MODULE AREA & WEIGHT CALCULATIONS <br />PANEL TYPES (COUNT, AREA, WEIGHT): <br />● (14x) SOLARIA POWER X-400R (400W) MODULES (67.8" x 44.7", 48.7 LB) <br />MICRO-INVERTER TYPES (COUNT, WEIGHT): <br />● (14x) IQ8M-72-2-US (240V) (2.38 LB) <br />ATTACHMENT COUNT: 25 <br />MOUNTING SYSTEM WEIGHT/MODULE: 1.5 LB <br />TOTAL ROOF AREA: 2613 SF <br />TOTAL ARRAY AREA: (14) 67.8" x 44.7" = 295 SF <br />TOTAL ARRAY WEIGHT: (14) 48.7 + (14) 2.4 + (14) 1.5 = 736 LB <br />WEIGHT AT EACH CONNECTION: 736 LB / 25 = 29.44 LB <br />DISTRIBUTED LOAD: 736 LB / 295 SF = 2.50 PSF <br />ROOF AREA COVERED BY ARRAY: 295 SF / 2613 SF = 11.3% <br />BILL OF MATERIALS <br />SOLAR PV MODULES 14 SOLARIA POWER X-400R (400W) MODULES <br />MICRO INVERTERS 14 IQ8M-72-2-US (240V) <br />JUNCTION BOX (AC) 01 <br />JUNCTION BOX <br />600V, NEMA 3R <br />UL LISTED <br />LOAD CENTER (AC) 01 AC COMBINER PANEL (MIN RATING 20A) <br />ATTACHMENTS 25 FLASHFOOT2 <br />RAIL 08 XR10 <br />RAIL SPLICES 04 RAIL SPLICES <br />MID CLAMPS 22 MID CLAMPS <br />END CLAMPS 12 END CLAMPS <br />GROUNDING LUG 03 GROUNDING LUG <br />ROOF DESCRIPTION TABLE <br />ROOF <br />PLANE <br />TRUSSES <br />SIZE <br />TRUSSES <br />SPACING <br />ATTACHMENT <br />SPACING <br />MODULE <br />COUNT <br />ARRAY <br />TILT <br />AZIMUTH <br />#1 2" x 6" 24" O.C. 72" O.C. 14 18° 155° <br />ROOF ACCESS POINT <br />● SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF <br />GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND <br />LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS <br />WHERETHE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-2 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />RY <br />A <br />N <br /> <br />M <br />A <br />D <br />D <br />E <br />N <br />90 <br />8 <br /> <br />C <br />L <br />E <br />M <br />E <br />N <br />S <br />E <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />, <br /> <br />U <br />S <br />A <br />CONTRACTOR: SUNERGY, INC. <br />ADDRESS: 23182 ALCALDE DR SUITE <br />GLAGUNA HILLS, CA 92653 <br />PHONE: (562) 544-7394 <br />LICENSE #: 1061794 <br />APN: - <br />EMAIL: - <br />PHONE: - <br />0002/17/2023 Initial Design <br />ROOF PLAN WITH MODULES <br />SCALE: 1/8" = 1'-0" <br />1 <br />ROOF PLAN WITH <br />MODULES <br />1 <br />ROOF ATTACHMENT <br />PV MODULE <br />AC <br />JB <br />MAIN SERVICE PANEL <br />(EXISTING, 200A) <br />UTILITY METER <br />(EXISTING) <br />AC DISCONNECT UNFUSED <br />(N/A) <br />ACF AC DISCONNECT FUSED <br />(N/A) <br />PRODUCTION METER <br />(N/A) <br />JUNCTION BOX <br />(NEW) <br />LOAD CENTER (COMBINER <br />PANEL) (NEW) <br />SOLAREDGE METER <br />(N/A) <br />SUBPANEL <br />(N/A) <br />DC DISCONNECT <br />(N/A) <br />DC COMBINER <br />(N/A) <br />OPTIMIZER <br />MICRO-INVERTER <br />EXISTING EQUIPMENT <br />AT <br />BACKUP LOAD PANEL <br />(N/A) <br />BATTERY <br />(N/A) <br />INV <br />SM <br />LC <br />BLP <br />SUB <br />DCC <br />DCD <br />EE <br />MSP <br />PM <br />UM <br />BAT <br />(0) INVERTER <br />(N/A) <br />AUTO TRANSFORMER <br />(N/A) <br />LE <br />G <br />E <br />N <br />D <br />ROOF <br />01 <br />PITCH <br /> <br />1 <br />8 <br />° <br />AZIM <br />U <br />T <br />H <br /> <br />155° <br />(E) F <br />R <br />O <br />N <br />T <br /> <br />Y <br />A <br />R <br />D <br />908 <br />C <br />L <br />E <br />M <br />E <br />N <br />S <br />E <br />N <br /> <br />A <br />V <br />E <br />36 <br />" <br /> <br />F <br />I <br />RE <br /> P <br />A <br />T <br />H <br />W <br />A <br />Y <br />36 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />P <br />A <br />T <br />H <br />W <br />A <br />Y <br />18" FIRE SETB <br />A <br />C <br />K <br />18" FIRE SETB <br />A <br />C <br />K <br />BACK <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />DESIGN CRITERIA <br />EXPOSURE CATEGORY = C <br />WIND SPEED = 100MPH <br />SNOW LOAD = 00LBS/FT2 <br />STRING <br />RAFTER <br />CONDUIT <br />RAILS <br />908 E Clemensen <br />Ave03/09/23