CANCELLED-1012 N King St - Plan
PBA
>
Building
>
ProjectDox
>
K
>
King St
>
1012 N King St
>
CANCELLED-1012 N King St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:20 PM
Creation date
6/1/2025 12:11:11 PM
Metadata
Fields
Template:
Plan
Permit Number
20182221
Full Address
1012 N King St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3 <br />(N) VISIBLE <br />LOCKABLE <br />2 POLE 60A <br />'KNIFE' AC <br />DISCONNECT <br />AC <br />DISCONNECT <br />TO BE LOCATED <br />WITHIN 10' OF <br />METER <br />M <br />POINT OF <br /> DELIVERY AND <br />INTERCONNECTION <br />100A <br />100A <br />N <br />4 (E) GROUNDING <br />ELECTRODE OR <br />(UFER) <br />EXISTING <br />240V/100A <br />MAIN SERVICE PANEL <br />SINGLE PHASE <br />3 <br />40A <br />BACKFEED <br />BREAKER <br /> ALL EXISTING LOADS <br />RELOCATED FROM MAIN <br />SERVICE PANEL TO NEW <br />SUB SERVICE PANEL <br />(N) 240V/125A <br />SUB SERVICE PANEL <br />SINGLE PHASE <br />N <br />(N) (11) JINKO SOLAR JKM395M-72HL-V(395W) MODULES <br /> WITH (6) AP SYSTEM DS3-L 2 IN 1 MICRO-INVERTER <br />ATTACHED TO THE BACK OF MODULE <br />112 1 <br />1 <br />PV CIRCUIT 2: 4 MODULES/PARALLEL [(2) AP SYSTEM DS3-L 2 IN 1] <br />PV CIRCUIT 1: 7 MODULES/PARALLEL [(4) AP SYSTEM DS3-L 2 IN 1] <br />112 <br />4 3 <br />RO <br />O <br />F <br />T <br />O <br />P <br />GR <br />O <br />U <br />N <br />D <br /> <br />L <br />E <br />V <br />E <br />L <br /> <br />- <br />HO <br />U <br />S <br />E <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />20A <br />20A <br />N <br />2(N) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE <br />GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH <br />END OF THE EMT CONDUIT WITH THE WIRE THEN FREE <br />AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL <br />(N) 100A PV LOAD <br />CENTER <br />6 57 <br />20A <br />EXISTING WIRE <br />12 <br />PV CIRCUIT 1: 12 MODULES/PARALLEL <br />12 <br />(E) JUNCTION BOX <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />(E) 12 PHONO SOLAR MODULES WITH A PS2250P(250W) <br />ENPHASE IQ-6-60-2-US MICRO-INVERTER <br />ATTACHED TO THE BACK OF EVERY MODULE. <br />(E) VISIBLE <br />LOCKABLE <br />2 POLE 30A <br />'KNIFE' AC <br />DISCONNECT <br />EXISTING WIRE <br />EXISTING WIRE M <br />(E) PV PRODUCTION METER <br />EXISTING WIRE <br />N N <br />SHEET <br />CONTRACTOR <br />SOLGEN CONSTRUCTION LLC. <br /> 1012 N KING ST, <br /> SANTA ANA, <br /> CA 92706 <br /> APN:40521403 <br /> DATE:2/23/2024 <br />ROSALES <br />RESIDENCE <br />License#: C-10 1053344 <br />DESIGNER: OAV <br />CORE ENERGY GROUP. <br />ADDRESS:2072 N MAIN ST <br />FL 2, LOGAN <br />UT 84341-1993 <br />CSLB#: 1053344 <br />E-1 <br />DESIGN TEMPERATURES <br />ASHRAE EXTREME LOW 2°C <br />ASHRAE 2% HIGH 36°C <br />PV Module Ratings @ STC <br />Module Make/Model <br />JINKO SOLAR <br />JKM395M-72HL-V(395W) <br />MODULE <br />Max Power-Point Current (Imp)9.55A <br />Max Power-Point Voltage (Vmp)41.4V <br />Open-Circuit Voltage (Voc)49.5V <br />Short-Circuit Current (Isc)10.23A <br />Max Series Fuse (OCPD)20A <br />Nominal Maximum Power at STC (Pmax)395W <br />Maximum System Voltage 1500V <br />Voc Temperature Coefficient -0.28% /°C <br />Conduit and Conductor Schedule~(75°C Copper column) <br />Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size <br />1 AP SYSTEM'S AC BUS CABLE 12 AWG 2 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 (CU)10 AWG 4 EMT 3/4" <br />2 THWN-2 - Ground (CU)8 AWG 1 EMT 3/4" <br />3 <br />3 <br />THWN-2 (CU)8 AWG 3 EMT 3/4" <br />THWN-2 - Ground (CU)8 AWG 1 EMT 3/4" <br />NOTE:TOTAL AMPERAGE RATING OF <br />ALL OVERCURRENT DEVICES SUMMED <br />UP IN THE MAIN PANEL EXCLUDING <br />MAIN SUPPLY OVERCURRENT DEVICE, <br />SHALL NOT EXCEED AMPACITY OF BUS <br />BAR CEC 2022 705.12(B)(3)(3) <br />Inverter Ratings <br />Inverter Make/Model AP SYSTEM DS3-L <br />Max DC Volt Rating 60V <br />Peak Output Power 768W <br />Max Nominal Voltage 240V <br />Max AC Current 3.2A <br />Max OCPD Rating 20A <br />METER # 222013506065 <br />NOTE:EXISTING PV SYSTEM IS RSD COMPLIANT <br />SYSTEM SUMMARY <br />BRANCH #1 <br />INVERTERS PER BRANCH 4 <br />MAX AC CURRENT 12.8A <br />MAX AC OUTPUT POWER 3072W <br />ARRAY STC POWER 4345W <br />ARRAY PTC POWER 4033W <br />MAX AC CURRENT 19.20A <br />MAX AC POWER 4608W <br />DERATED (CEC) AC POWER 3891.84W <br />BRANCH #2 <br />2 <br />6.4A <br />1536W <br />SUB SERVICE PANEL <br />240/120V 1Ø, 3W <br />MAIN BUSS: 125A <br />MAX BREAKER SIZE: <br />(125A X 1.2) - 100A = 50A4 <br />4 <br />THWN-2 (AL)1AWG 3 EMT 1-1/4" <br />THWN-2 - Ground (AL)6 AWG 1 EMT 1-1/4" <br />1012 N King St- <br />101118433, 201822213/13/2024